Calibration of a phoswich type partial body counter by Monte Carlo simulation of low-energy photon transport

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CALIBRATION; HUMAN; IMAGE QUALITY; INSTRUMENTATION; LIVER; LUNG; MALE; METHODOLOGY; MONTE CARLO METHOD; PHOTON; RADIATION EXPOSURE; RADIATION MONITORING;

EID: 34548754407     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/ncl503     Document Type: Article
Times cited : (9)

References (18)
  • 1
    • 0029975723 scopus 로고    scopus 로고
    • A calibration method for whole-body counters, using Monte Carlo simulation
    • Ishikawa, T., Matsumoto, M. and Uchiyama, M. A calibration method for whole-body counters, using Monte Carlo simulation. Radiat. Prot. Dosim. 64, 283-288 (1996).
    • (1996) Radiat. Prot. Dosim. , vol.64 , pp. 283-288
    • Ishikawa, T.1    Matsumoto, M.2    Uchiyama, M.3
  • 3
    • 0029054765 scopus 로고
    • Development of a method for calibrating in-vivo measurement systems using magnetic resonance imaging and Monte Carlo computations
    • Mallet, M. W., Hickman, D. P., Kruchten, D. A. and Poston, J. W. Sr. Development of a method for calibrating in-vivo measurement systems using magnetic resonance imaging and Monte Carlo computations. Health Phys. 68, 773-785 (1995).
    • (1995) Health Phys. , vol.68 , pp. 773-785
    • Mallet, M.W.1    Hickman, D.P.2    Kruchten, D.A.3    Poston J.W., Sr.4
  • 6
    • 0032960329 scopus 로고    scopus 로고
    • Evaluation of the effect of chest wall thickness, tissue composition, and photon energy on the quantity muscle-equivalent chestwall-thickness by Monte Carlo simulation
    • Kramer, G. H. and Burns, L. C. Evaluation of the effect of chest wall thickness, tissue composition, and photon energy on the quantity muscle-equivalent chestwall-thickness by Monte Carlo simulation. Radiat. Prot. Dosim. 82, 115-124 (1999).
    • (1999) Radiat. Prot. Dosim. , vol.82 , pp. 115-124
    • Kramer, G.H.1    Burns, L.C.2
  • 7
    • 77955835560 scopus 로고
    • New York University Medical Center, Persönliche Mitteilung
    • Cohen, N. Institute of Environmental Medicine, New York University Medical Center, Persönliche Mitteilung (1987).
    • (1987) Institute of Environmental Medicine
    • Cohen, N.1
  • 8
    • 0022137003 scopus 로고
    • The U.S. transuranium registry report on the Am-241 content of a whole body, part Iv, preparation and analysis of the tissues and bones
    • McInroy, J. F., Boyd, H. A., Eutsler, B. C. and Romero, D. The U.S. transuranium registry report on the Am-241 content of a whole body, part Iv, preparation and analysis of the tissues and bones. Health Phys. 49(4), 587-621 (1985).
    • (1985) Health Phys , vol.49 , Issue.4 , pp. 587-621
    • McInroy, J.F.1    Boyd, H.A.2    Eutsler, B.C.3    Romero, D.4
  • 9
    • 0003395844 scopus 로고    scopus 로고
    • Briesmeister, J. F., Ed. Report LA-13709-M (Los Alamos National Laboratory, Los Alamos, NM)
    • Briesmeister, J. F., Ed. MCNP-a general Monte Carlo code n-particle transport code. Report LA-13709-M (Los Alamos National Laboratory, Los Alamos, NM) (2000).
    • (2000) MCNP-a general Monte Carlo code n-particle transport code
  • 12
  • 15
    • 0025997238 scopus 로고
    • Viewpoint: the visible human project
    • Ackerman, M. J. Viewpoint: the visible human project. J. Biocommun. 18(2), 14 (1991).
    • (1991) J. Biocommun. , vol.18 , Issue.2 , pp. 14
    • Ackerman, M.J.1
  • 17
    • 0004322164 scopus 로고
    • International Commission on Radiological Protection., ICRP Publication 23 (Oxford: Pergamon Press)
    • International Commission on Radiological Protection. Reference man: anatomical, physiological and metabolic characteristics. ICRP Publication 23 (Oxford: Pergamon Press) (1975).
    • (1975) Reference man: anatomical, physiological and metabolic characteristics