메뉴 건너뛰기




Volumn , Issue , 2007, Pages 1-4

In vivo implant mechanics of single-shaft microelectrodes in peripheral nervous tissue

Author keywords

Electrode; Implant mechanics; Peripheral nerve

Indexed keywords

BENDING MOMENTS; IMPLANTS (SURGICAL); MECHANICS; NEUROLOGY; SILICON; STRENGTH OF MATERIALS; TISSUE; TUNGSTEN;

EID: 34548718742     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/CNE.2007.369596     Document Type: Conference Paper
Times cited : (12)

References (16)
  • 3
    • 0036370615 scopus 로고    scopus 로고
    • Hofmann UG, Folkers A, Mosch F, Höhl D, Kindlundh M, and Norlin P, A 64(128)-channel Multisite Neuronal Recording System, Biomed Tech (Berl), 47, no. Suppl 1 Pt 1, pp. 194-197, 2002.
    • Hofmann UG, Folkers A, Mosch F, Höhl D, Kindlundh M, and Norlin P, "A 64(128)-channel Multisite Neuronal Recording System," Biomed Tech (Berl), vol. 47, no. Suppl 1 Pt 1, pp. 194-197, 2002.
  • 8
    • 0036713929 scopus 로고    scopus 로고
    • Associative Interaction Within the Superficial Layers of the Entorhinal Cortex of the Guinea Pig
    • Biella G, Uva L, Hofmann UG, and de Curtis M, "Associative Interaction Within the Superficial Layers of the Entorhinal Cortex of the Guinea Pig," J Neurophyslol, vol. 88, pp. 1159-1165, 2002.
    • (2002) J Neurophyslol , vol.88 , pp. 1159-1165
    • Biella, G.1    Uva, L.2    Hofmann, U.G.3    de Curtis, M.4
  • 9
    • 0037067985 scopus 로고    scopus 로고
    • Peripheral Stimuli Excite Coronal Beams of Golgi Cells in Rat Cerebellar Cortex
    • Volny-Luraghi A, Maex R, Vos B, and de Schutter E, "Peripheral Stimuli Excite Coronal Beams of Golgi Cells in Rat Cerebellar Cortex," Neuroscience, vol. 113, no. 2, pp. 363-373, 2002.
    • (2002) Neuroscience , vol.113 , Issue.2 , pp. 363-373
    • Volny-Luraghi, A.1    Maex, R.2    Vos, B.3    de Schutter, E.4
  • 10
    • 0034934968 scopus 로고    scopus 로고
    • Network Activity Evoked by Neocortical Stimulation in Area 36 of the Guinea Pig Perirhinal Cortex
    • Biella G, Uva L, and de Curtis M, "Network Activity Evoked by Neocortical Stimulation in Area 36 of the Guinea Pig Perirhinal Cortex," J Neurophyslol, vol. 86, pp. 164-172, 2001.
    • (2001) J Neurophyslol , vol.86 , pp. 164-172
    • Biella, G.1    Uva, L.2    de Curtis, M.3
  • 11
    • 0026882265 scopus 로고
    • Factors Influencing the Biocompatibility of Insertable Silicon Microshafts in Cerebral Cortex
    • Edell DJ, Toi W, McNeil VM, and Clark LD, "Factors Influencing the Biocompatibility of Insertable Silicon Microshafts in Cerebral Cortex," IEEE Trans Biomed Eng, vol. 39, no. 6, pp. 635-643, 1992.
    • (1992) IEEE Trans Biomed Eng , vol.39 , Issue.6 , pp. 635-643
    • Edell, D.J.1    Toi, W.2    McNeil, V.M.3    Clark, L.D.4
  • 12
    • 0025435155 scopus 로고
    • Strength characterization of silicon microprobes in neurophysiological tissues
    • Najafi K and Hetke J, "Strength characterization of silicon microprobes in neurophysiological tissues," IEEE Trans Biomed Eng, vol. 37, no. 5, pp. 474-81, 1990.
    • (1990) IEEE Trans Biomed Eng , vol.37 , Issue.5 , pp. 474-481
    • Najafi, K.1    Hetke, J.2
  • 13
    • 0025359786 scopus 로고
    • Scaling Limitation of Silicon Multichannel Recording Probes
    • Najafi K, Ji J, and Wise KD, "Scaling Limitation of Silicon Multichannel Recording Probes," IEEE Trans Biomed Eng, vol. 37, no. 1, pp. 1-11, 1990.
    • (1990) IEEE Trans Biomed Eng , vol.37 , Issue.1 , pp. 1-11
    • Najafi, K.1    Ji, J.2    Wise, K.D.3
  • 14
    • 0029081786 scopus 로고
    • Feasibility of a central nervous system auditory prosthesis: Penetrating microelectrode insertion force studies
    • Portillo F, Mobley P, Moore J, and McCreery D, "Feasibility of a central nervous system auditory prosthesis: penetrating microelectrode insertion force studies," Ann Otol Rhinol Laryngol Suppl, vol. 166, pp. 31-33, 1995.
    • (1995) Ann Otol Rhinol Laryngol Suppl , vol.166 , pp. 31-33
    • Portillo, F.1    Mobley, P.2    Moore, J.3    McCreery, D.4
  • 15
    • 0033010903 scopus 로고    scopus 로고
    • Measurement of the Force Required to Move a Neurosurgical Probe Through in vivo Human Brain Tissue
    • Howard MA, Abkes BA, Ollendieck MC, Noh MD, Ritter RC, and Gillies GT, "Measurement of the Force Required to Move a Neurosurgical Probe Through in vivo Human Brain Tissue," IEEE Trans Biomed Eng, vol. 46, no. 7, pp. 891-894, 1999.
    • (1999) IEEE Trans Biomed Eng , vol.46 , Issue.7 , pp. 891-894
    • Howard, M.A.1    Abkes, B.A.2    Ollendieck, M.C.3    Noh, M.D.4    Ritter, R.C.5    Gillies, G.T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.