메뉴 건너뛰기




Volumn 45, Issue 10, 2007, Pages 957-967

An augmented reality simulator for ultrasound guided needle placement training

Author keywords

Augmented reality; Needle placement; Simulation; Ultrasound

Indexed keywords

COMPUTER SIMULATION; COMPUTERIZED TOMOGRAPHY; PERSONNEL TRAINING; RADIOLOGY;

EID: 34548718157     PISSN: 01400118     EISSN: None     Source Type: Journal    
DOI: 10.1007/s11517-007-0231-9     Document Type: Article
Times cited : (80)

References (22)
  • 3
    • 33746909142 scopus 로고    scopus 로고
    • Procedural simulation: A primer
    • Dawson S (2006) Procedural simulation: A primer. J Vasc Interv Radiol 17:205-213
    • (2006) J Vasc Interv Radiol , vol.17 , pp. 205-213
    • Dawson, S.1
  • 6
    • 0019574599 scopus 로고
    • Random sample consensus: A paradigm for model fitting with applications to image analysis and automated cartography
    • Fischler M, Bolles R (1981) Random sample consensus: A paradigm for model fitting with applications to image analysis and automated cartography. Graph Image Process 24(6):381-395
    • (1981) Graph Image Process , vol.24 , Issue.6 , pp. 381-395
    • Fischler, M.1    Bolles, R.2
  • 8
    • 33745122651 scopus 로고    scopus 로고
    • Simulators in catheter-based interventional radiology: Training or computer games
    • Gould D, Kessel D, Healey A, Johnson S, Lewandowski W (2006b) Simulators in catheter-based interventional radiology: Training or computer games. Clin Radiol 61:556-561
    • (2006) Clin Radiol , vol.61 , pp. 556-561
    • Gould, D.1    Kessel, D.2    Healey, A.3    Johnson, S.4    Lewandowski, W.5
  • 10
    • 0037897066 scopus 로고    scopus 로고
    • Combining 3D deformable models and level set methods for the segmentation of abdominal aortic aneurisms
    • Magee D, Bulpitt A, Berry E (2001) Combining 3D deformable models and level set methods for the segmentation of abdominal aortic aneurisms. Proc Br Mach Vis Conf 1:333-341
    • (2001) Proc Br Mach Vis Conf , vol.1 , pp. 333-341
    • Magee, D.1    Bulpitt, A.2    Berry, E.3
  • 11
    • 27744508576 scopus 로고    scopus 로고
    • A computer based simulator for ultrasound guided needle insertion procedures
    • Magee D, Kessel D (2005) A computer based simulator for ultrasound guided needle insertion procedures. IEE Conf Vis Inf Eng 1:301-308
    • (2005) IEE Conf Vis Inf Eng , vol.1 , pp. 301-308
    • Magee, D.1    Kessel, D.2
  • 15
    • 0036143951 scopus 로고    scopus 로고
    • Virtual reality and simulation: Training the future emergency physician
    • Reznek M, Harter P, Krummel T (2002) Virtual reality and simulation: training the future emergency physician. Acad Emerg Med 9:78-87
    • (2002) Acad Emerg Med , vol.9 , pp. 78-87
    • Reznek, M.1    Harter, P.2    Krummel, T.3
  • 16
    • 0036917463 scopus 로고    scopus 로고
    • Face-, expert and referent validity of the Xitact LS500 Laparoscopy simulator
    • Schijven M, Jakimowicz J (2002) Face-, expert and referent validity of the Xitact LS500 Laparoscopy simulator. Surg Endosc 16:1764-1770
    • (2002) Surg Endosc , vol.16 , pp. 1764-1770
    • Schijven, M.1    Jakimowicz, J.2
  • 17
    • 0038414784 scopus 로고    scopus 로고
    • Construct validity: Experts and novices performing on the Xitact LS500 Laparoscopy simulator
    • Schijven M, Jakimowicz J (2003) Construct validity: Experts and novices performing on the Xitact LS500 Laparoscopy simulator. Surg Endosc 17:803-810
    • (2003) Surg Endosc , vol.17 , pp. 803-810
    • Schijven, M.1    Jakimowicz, J.2
  • 19
    • 0036785870 scopus 로고    scopus 로고
    • Virtual reality training improves operating room performance: Results of a randomized, double-blinded study
    • Seymour N, Gallagher A, Roman S et al (2002) Virtual reality training improves operating room performance: Results of a randomized, double-blinded study. Ann Surg 236:458-464
    • (2002) Ann Surg , vol.236 , pp. 458-464
    • Seymour, N.1    Gallagher, A.2    Roman, S.3
  • 20
    • 0035161989 scopus 로고    scopus 로고
    • The learning curve and sentinel node biopsy
    • Tafra L (2001) The learning curve and sentinel node biopsy. Am J Surg 182:347-350
    • (2001) Am J Surg , vol.182 , pp. 347-350
    • Tafra, L.1
  • 21
    • 0032414046 scopus 로고    scopus 로고
    • Real-time interactive simulator for percutaneous coronary revascularization procedures
    • Wang Y, Chui C, Lim H, Cai Y, Mak K (1998) Real-time interactive simulator for percutaneous coronary revascularization procedures. Comput Aided Surg 3:211-227
    • (1998) Comput Aided Surg , vol.3 , pp. 211-227
    • Wang, Y.1    Chui, C.2    Lim, H.3    Cai, Y.4    Mak, K.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.