메뉴 건너뛰기




Volumn 74, Issue 1, 2007, Pages

A MC tool for CT-based calculations of dose delivery and activation in proton therapy

Author keywords

[No Author keywords available]

Indexed keywords


EID: 34548682352     PISSN: 17426588     EISSN: 17426596     Source Type: Conference Proceeding    
DOI: 10.1088/1742-6596/74/1/021013     Document Type: Article
Times cited : (5)

References (20)
  • 1
    • 17844375162 scopus 로고    scopus 로고
    • Distributions of β+ decayed nuclei generated in the CH2 and H2O targets by target nuclear fragment reaction using therapeutic MONO and SOBP proton beam.
    • 2O targets by target nuclear fragment reaction using therapeutic MONO and SOBP proton beam. Med. Phys. 32 1070-82
    • (2005) Med. Phys. , vol.32 , Issue.4 , pp. 1070-1082
    • Nishio, T.1    Sato, T.2    Kitamura, H.3    Murakami, K.4    Ogino, T.5
  • 2
    • 23844461860 scopus 로고    scopus 로고
    • Experimental study on the feasibility of in-beam PET for accurate monitoring of proton therapy
    • Parodi K, Pönisch F and Enghardt W 2005 Experimental study on the feasibility of in-beam PET for accurate monitoring of proton therapy IEEE Trans. Nucl. Sci. 52 778-86
    • (2005) IEEE Trans. Nucl. Sci. , vol.52 , Issue.3 , pp. 778-786
    • Parodi, K.1    Pönisch, F.2    Enghardt, W.3
  • 3
    • 33846585941 scopus 로고    scopus 로고
    • PET/CT imaging for treatment verification after proton therapy - A study with plastic phantoms and metallic implants
    • Parodi K, H Paganetti, E Cascio, J Flanz, A Bonab, N Alpert, K Lohmann and T Bortfeld 2007 PET/CT imaging for treatment verification after proton therapy - a study with plastic phantoms and metallic implants Med. Phys. 34 419-35
    • (2007) Med. Phys. , vol.34 , Issue.2 , pp. 419-435
    • Parodi, K.1    Paganetti, H.2    Cascio, E.3    Flanz, J.4    Bonab, A.5    Alpert, N.6    Lohmann, K.7    Bortfeld, T.8
  • 6
    • 11044221998 scopus 로고    scopus 로고
    • The description of positron emitter production and PET imaging during carbon ion therapy
    • Pönisch F, Parodi K, Hasch B G and Enghardt W 2004 The description of positron emitter production and PET imaging during carbon ion therapy Phys. Med. Biol. 49 5217-32
    • (2004) Phys. Med. Biol. , vol.49 , Issue.23 , pp. 5217-5232
    • Pönisch, F.1    Parodi, K.2    Hasch, B.G.3    Enghardt, W.4
  • 9
    • 3142702743 scopus 로고    scopus 로고
    • Accurate Monte Carlo simulations for nozzle design, commissioning and quality assurance for a proton radiation therapy facility
    • Paganetti H, Jiang H, Lee S-Y and Kooy H 2004 Accurate Monte Carlo simulations for nozzle design, commissioning and quality assurance for a proton radiation therapy facility Med. Phys. 31 2107-18
    • (2004) Med. Phys. , vol.31 , Issue.7 , pp. 2107-2118
    • Paganetti, H.1    Jiang, H.2    Lee, S.-Y.3    Kooy, H.4
  • 11
    • 0033354409 scopus 로고    scopus 로고
    • Physical and biophysical characteristics of a fully modulated 72 MeV therapeutic proton beam: Model predictions and experimental data
    • Biaggi M, Ballarini F, Burkard W, Egger E, Ferrari A and Ottolenghi A 1999 Physical and biophysical characteristics of a fully modulated 72 MeV therapeutic proton beam: model predictions and experimental data Nucl. Instrum. Meth. Phys. Res. B 159 89-100
    • (1999) Nucl. Instrum. Meth. Phys. Res. , vol.159 , Issue.1-2 , pp. 89-100
    • Biaggi, M.1    Ballarini, F.2    Burkard, W.3    Egger, E.4    Ferrari, A.5    Ottolenghi, A.6
  • 13
    • 0033983759 scopus 로고    scopus 로고
    • Correlation between CT numbers and tissue parameters needed for Monte Carlo simulations of clinical dose distributions
    • Schneider W, Bortfeld T and Schlegel W 2000 Correlation between CT numbers and tissue parameters needed for Monte Carlo simulations of clinical dose distributions Phys. Med. Biol. 45 459-78
    • (2000) Phys. Med. Biol. , vol.45 , Issue.2 , pp. 459-478
    • Schneider, W.1    Bortfeld, T.2    Schlegel, W.3
  • 14
    • 4744360413 scopus 로고    scopus 로고
    • Adaption of GEANT4 to Monte Carlo dose calculations based on CT data
    • Jiang H and Paganetti H 2004 Adaption of GEANT4 to Monte Carlo dose calculations based on CT data Med. Phys. 31 2811-8
    • (2004) Med. Phys. , vol.31 , Issue.10 , pp. 2811-2818
    • Jiang, H.1    Paganetti, H.2
  • 15
    • 34249684860 scopus 로고    scopus 로고
    • Clinical CT-based calculations of dose and positron emitter distributions in proton therapy using the FLUKA Monte Carlo code
    • Parodi K, Ferrari A, Sommerer F and Paganetti H Clinical CT-based calculations of dose and positron emitter distributions in proton therapy using the FLUKA Monte Carlo code Phys. Med. Biol submitted
    • Phys. Med. Biol
    • Parodi, K.1    Ferrari, A.2    Sommerer, F.3    Paganetti, H.4
  • 19
    • 33747627407 scopus 로고    scopus 로고
    • Investigatingthe accuracy of the FLUKA code for transport of therapeutic ion beams in matter
    • Sommerer F, Parodi K, Ferrari A, Poljanc K, Enghardt W and Aiginger H 2006 Investigatingthe accuracy of the FLUKA code for transport of therapeutic ion beams in matter Phys. Med. Biol. 51 4385-98
    • (2006) Phys. Med. Biol. , vol.51 , Issue.17 , pp. 4385-4398
    • Sommerer, F.1    Parodi, K.2    Ferrari, A.3    Poljanc, K.4    Enghardt, W.5    Aiginger, H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.