Application of ICP-QMS for the determination of plutonium in environmental samples for safeguards purposes

Author keywords

Environmental samples; ICP MS; Isotope dilution; Isotope ratio; Plutonium; Safeguards

Indexed keywords

CHROMATOGRAPHIC ANALYSIS; ENVIRONMENTAL IMPACT; ISOTOPES; NUCLEAR MATERIALS SAFEGUARDS;

EID: 34548679829     PISSN: 0265931X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jenvrad.2007.03.010     Document Type: Article
Times cited : (28)

References (26)
  • 2
    • 34548679878 scopus 로고    scopus 로고
    • Ballestra, S., Gastaud, J., Lopez, J.J., Parsi, P., Vas, D., 1993. Intercomparation of radionuclides measurements in marine sediment sample IAEA-135, Marine Environmental Laboratory, International Atomic Energy Agency, Monaco, 63 pp. Available at: .
  • 3
    • 0036025840 scopus 로고    scopus 로고
    • Isotopic analysis of uranium and plutonium using ICP-MS and estimation of burn-up of spent uranium in contaminated environmental samples
    • Boulyga S.F., and Becker J.S. Isotopic analysis of uranium and plutonium using ICP-MS and estimation of burn-up of spent uranium in contaminated environmental samples. J. Anal. At. Spectrom. 17 (2002) 1143-1147
    • (2002) J. Anal. At. Spectrom. , vol.17 , pp. 1143-1147
    • Boulyga, S.F.1    Becker, J.S.2
  • 4
    • 0001325143 scopus 로고    scopus 로고
    • Precise isotope ratio measurements for uranium, thorium and plutonium by quadrupole inductively coupled plasma mass spectrometry
    • Becker J.S., and Dietze H.-J. Precise isotope ratio measurements for uranium, thorium and plutonium by quadrupole inductively coupled plasma mass spectrometry. Fresenius' J. Anal. Chem. 364 (1999) 482-488
    • (1999) Fresenius' J. Anal. Chem. , vol.364 , pp. 482-488
    • Becker, J.S.1    Dietze, H.-J.2
  • 5
    • 0032490402 scopus 로고    scopus 로고
    • Determination of plutonium in seawater using co-precipitation and inductively coupled plasma mass spectrometry with ultrasonic nebulisation
    • Eroglu A.E., McLeod C.W., Leonard K.S., and McCubbin D. Determination of plutonium in seawater using co-precipitation and inductively coupled plasma mass spectrometry with ultrasonic nebulisation. Spectrochim. Acta, Part B 53 (1998) 1221-1233
    • (1998) Spectrochim. Acta, Part B , vol.53 , pp. 1221-1233
    • Eroglu, A.E.1    McLeod, C.W.2    Leonard, K.S.3    McCubbin, D.4
  • 6
    • 77956988785 scopus 로고
    • Stationary phases in extraction chromatography
    • Braun T., and Ghersini G. (Eds), Elsevier Scientific Publishing Company, New York
    • Ghersini G. Stationary phases in extraction chromatography. In: Braun T., and Ghersini G. (Eds). Extraction Chromatography (1975), Elsevier Scientific Publishing Company, New York 68-133
    • (1975) Extraction Chromatography , pp. 68-133
    • Ghersini, G.1
  • 7
    • 23444447427 scopus 로고    scopus 로고
    • The development of low-level measurement capabilities for total and isotopic uranium in environmental samples at Brazilian and Argentine laboratories by ABACC
    • Guidicini O.Y., Olsen K.B., Hembree Jr. D.M., Carter J.A., Whitacker J.M., and Hayes S.M. The development of low-level measurement capabilities for total and isotopic uranium in environmental samples at Brazilian and Argentine laboratories by ABACC. J. Nucl. Mater. Manage. 33 (2005) 4-12
    • (2005) J. Nucl. Mater. Manage. , vol.33 , pp. 4-12
    • Guidicini, O.Y.1    Olsen, K.B.2    Hembree Jr., D.M.3    Carter, J.A.4    Whitacker, J.M.5    Hayes, S.M.6
  • 9
    • 34548660573 scopus 로고    scopus 로고
    • International Atomic Energy Agency, 2005. Procedure for the qualification of a candidate laboratory for the Agency's NWAL for analysis of safeguards samples. SGTCS-P22/Rev. 2-2005, 24 pp.
  • 10
    • 0036027087 scopus 로고    scopus 로고
    • Determination of plutonium isotopes and neptunium-237 in environmental samples by inductively coupled plasma mass spectrometry with total sample dissolution
    • Kenna T.C. Determination of plutonium isotopes and neptunium-237 in environmental samples by inductively coupled plasma mass spectrometry with total sample dissolution. J. Anal. At. Spectrom. 17 (2002) 1471-1479
    • (2002) J. Anal. At. Spectrom. , vol.17 , pp. 1471-1479
    • Kenna, T.C.1
  • 11
    • 1842851774 scopus 로고    scopus 로고
    • Rapid dating of recent sediments in Loch Ness: inductively coupled plasma mass spectrometric measurements of global fallout plutonium
    • Ketterer M.E., Hafer K.M., Jones V.J., and Appleby P.G. Rapid dating of recent sediments in Loch Ness: inductively coupled plasma mass spectrometric measurements of global fallout plutonium. Sci. Total Environ. 322 (2004) 221-229
    • (2004) Sci. Total Environ. , vol.322 , pp. 221-229
    • Ketterer, M.E.1    Hafer, K.M.2    Jones, V.J.3    Appleby, P.G.4
  • 12
    • 1542411344 scopus 로고    scopus 로고
    • Resolving Chernobyl vs. global fall-out contributions in soils from Poland using plutonium atom ratios measured by inductively coupled plasma mass spectrometry
    • Ketterer M.E., Hafer K.M., and Mietelski J.W. Resolving Chernobyl vs. global fall-out contributions in soils from Poland using plutonium atom ratios measured by inductively coupled plasma mass spectrometry. J. Environ. Radioact. 73 (2004) 183-201
    • (2004) J. Environ. Radioact. , vol.73 , pp. 183-201
    • Ketterer, M.E.1    Hafer, K.M.2    Mietelski, J.W.3
  • 14
    • 0035206415 scopus 로고    scopus 로고
    • Rapid separation of plutonium in environmental samples using anion exchange resin disk
    • Miura T., Oikawa S., Kishimoto T., Banba S., and Morimoto T. Rapid separation of plutonium in environmental samples using anion exchange resin disk. J. Radioanal. Nucl. Chem. 250 (2001) 449-452
    • (2001) J. Radioanal. Nucl. Chem. , vol.250 , pp. 449-452
    • Miura, T.1    Oikawa, S.2    Kishimoto, T.3    Banba, S.4    Morimoto, T.5
  • 15
    • 0030953375 scopus 로고    scopus 로고
    • Identification of the contamination source of plutonium in environmental samples with isotopic ratios determined by inductively coupled plasma mass spectrometry and alpha-spectrometry
    • Momoshima N., Kakiuchi H., Maeda Y., Hirai E., and Ono T. Identification of the contamination source of plutonium in environmental samples with isotopic ratios determined by inductively coupled plasma mass spectrometry and alpha-spectrometry. J. Radioanal. Nucl. Chem. 221 (1997) 213-217
    • (1997) J. Radioanal. Nucl. Chem. , vol.221 , pp. 213-217
    • Momoshima, N.1    Kakiuchi, H.2    Maeda, Y.3    Hirai, E.4    Ono, T.5
  • 16
    • 0032660994 scopus 로고    scopus 로고
    • Determination of plutonium concentration and its isotopic ratio in environmental materials by ICP-MS after separation using ion-exchange and extraction chromatography
    • Muramatsu Y., Uchida S., Tagami K., Yoshida S., and Fujikawa T. Determination of plutonium concentration and its isotopic ratio in environmental materials by ICP-MS after separation using ion-exchange and extraction chromatography. J. Anal. At. Spectrom. 14 (1999) 859-865
    • (1999) J. Anal. At. Spectrom. , vol.14 , pp. 859-865
    • Muramatsu, Y.1    Uchida, S.2    Tagami, K.3    Yoshida, S.4    Fujikawa, T.5
  • 18
    • 0037341067 scopus 로고    scopus 로고
    • Determination of Pu concentration and its isotope ratio in Japanese soils by HR-ICP-MS
    • Muramatsu Y., Uchida S., and Tanaka A. Determination of Pu concentration and its isotope ratio in Japanese soils by HR-ICP-MS. J. Radioanal. Nucl. Chem. 255 (2003) 477-480
    • (2003) J. Radioanal. Nucl. Chem. , vol.255 , pp. 477-480
    • Muramatsu, Y.1    Uchida, S.2    Tanaka, A.3
  • 20
    • 0348167503 scopus 로고    scopus 로고
    • Separation of plutonium from soil and sediment prior to determination by inductively coupled plasma mass spectrometry
    • Nygren U., Rodushkin I., Nilsson C., and Baxter D.C. Separation of plutonium from soil and sediment prior to determination by inductively coupled plasma mass spectrometry. J. Anal. At. Spectrom. 18 (2003) 1426-1434
    • (2003) J. Anal. At. Spectrom. , vol.18 , pp. 1426-1434
    • Nygren, U.1    Rodushkin, I.2    Nilsson, C.3    Baxter, D.C.4
  • 21
    • 0032324634 scopus 로고    scopus 로고
    • High resolution inductively coupled plasma mass spectrometry for the trace determination of plutonium isotopes and isotope ratios in environmental samples
    • Stürup S., Dahlgaard H., and Nielsen S.C. High resolution inductively coupled plasma mass spectrometry for the trace determination of plutonium isotopes and isotope ratios in environmental samples. J. Anal. At. Spectrom. 13 (1998) 1321-1326
    • (1998) J. Anal. At. Spectrom. , vol.13 , pp. 1321-1326
    • Stürup, S.1    Dahlgaard, H.2    Nielsen, S.C.3
  • 23
    • 0035526846 scopus 로고    scopus 로고
    • ICP-sector field mass spectrometry analysis of plutonium: recognizing and resolving potential interferences
    • Wyse E.J., Lee S.H., LaRosa J., Povinec P., and de Mora S.J. ICP-sector field mass spectrometry analysis of plutonium: recognizing and resolving potential interferences. J. Anal. At. Spectrom. 16 (2001) 1107-1111
    • (2001) J. Anal. At. Spectrom. , vol.16 , pp. 1107-1111
    • Wyse, E.J.1    Lee, S.H.2    LaRosa, J.3    Povinec, P.4    de Mora, S.J.5
  • 24
    • 30944469146 scopus 로고    scopus 로고
    • Determination of Pu isotopes in sediment cores in the Sea of Okhotsk and the NW Pacific by sector field ICP-MS
    • Zheng J., and Yamada M. Determination of Pu isotopes in sediment cores in the Sea of Okhotsk and the NW Pacific by sector field ICP-MS. J. Radioanal. Nucl. Chem. 267 (2006) 73-83
    • (2006) J. Radioanal. Nucl. Chem. , vol.267 , pp. 73-83
    • Zheng, J.1    Yamada, M.2
  • 25
    • 33744998459 scopus 로고    scopus 로고
    • Inductively coupled plasma-sector field mass spectrometry with a high-efficiency sample introduction system for the determination of Pu isotopes in settling particles at femtogram levels
    • Zheng J., and Yamada M. Inductively coupled plasma-sector field mass spectrometry with a high-efficiency sample introduction system for the determination of Pu isotopes in settling particles at femtogram levels. Talanta 69 (2006) 1246-1253
    • (2006) Talanta , vol.69 , pp. 1246-1253
    • Zheng, J.1    Yamada, M.2
  • 26
    • 14244263691 scopus 로고    scopus 로고
    • Determination of plutonium and its isotopic ratio in marine sediments using quadrupole ICP-MS with the shield torch system under normal plasma conditions
    • Zheng J., Yamada M., Wang Z., Aono T., and Kusakabe M. Determination of plutonium and its isotopic ratio in marine sediments using quadrupole ICP-MS with the shield torch system under normal plasma conditions. Anal. Bioanal. Chem. 379 (2004) 532-539
    • (2004) Anal. Bioanal. Chem. , vol.379 , pp. 532-539
    • Zheng, J.1    Yamada, M.2    Wang, Z.3    Aono, T.4    Kusakabe, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.