메뉴 건너뛰기




Volumn 334, Issue 3, 2007, Pages 209-211

Late right ventricular perforation and hemothorax after transvenous defibrillator lead implantation

Author keywords

Cardiac perforation; Computed tomography; Hemothorax; Implantable cardioverter defibrillator

Indexed keywords

ANALGESIC AGENT; ANTIINFLAMMATORY AGENT; CARVEDILOL; DIGOXIN; EPLERENONE; FUROSEMIDE; LEVOFLOXACIN;

EID: 34548668426     PISSN: 00029629     EISSN: None     Source Type: Journal    
DOI: 10.1097/MAJ.0b013e31814254c5     Document Type: Article
Times cited : (8)

References (10)
  • 1
    • 0028819419 scopus 로고
    • Low incidence of lead related complications associated with nonthoracotomy implantable cardioverter defibrillator systems
    • Fahy GJ, Kleman JM, Wilkoff BL, et al. Low incidence of lead related complications associated with nonthoracotomy implantable cardioverter defibrillator systems. Pacing Clin Electrophysiol 1995;18:172-8.
    • (1995) Pacing Clin Electrophysiol , vol.18 , pp. 172-178
    • Fahy, G.J.1    Kleman, J.M.2    Wilkoff, B.L.3
  • 2
    • 0030008104 scopus 로고    scopus 로고
    • Perforation of the right ventricle by transvenous defibrillator leads: Prevention and treatment
    • Molina JE. Perforation of the right ventricle by transvenous defibrillator leads: prevention and treatment. Pacing Clin Electrophysiol 1996;19:288-92.
    • (1996) Pacing Clin Electrophysiol , vol.19 , pp. 288-292
    • Molina, J.E.1
  • 3
    • 0035110248 scopus 로고    scopus 로고
    • Recurrent pericardial chest pain: A case of late right ventricular perforation after implantation of a transvenous active-fixation ICD lead
    • Kautzner J, Bytesnik J. Recurrent pericardial chest pain: a case of late right ventricular perforation after implantation of a transvenous active-fixation ICD lead. Pacing Clin Electrophysiol 2001;24:116-8.
    • (2001) Pacing Clin Electrophysiol , vol.24 , pp. 116-118
    • Kautzner, J.1    Bytesnik, J.2
  • 4
    • 0036693637 scopus 로고    scopus 로고
    • Complications of active-fixation electrodes
    • Vlay SC. Complications of active-fixation electrodes. Pacing Clin Electrophysiol 2002;25:1153-4.
    • (2002) Pacing Clin Electrophysiol , vol.25 , pp. 1153-1154
    • Vlay, S.C.1
  • 5
    • 33646505037 scopus 로고    scopus 로고
    • Computed tomography to assess possible cardiac lead perforation
    • Henrikson CA, Leng CT, Yuh DD, et al. Computed tomography to assess possible cardiac lead perforation. Pacing Clin Electrophysiol 2006;29:509-11.
    • (2006) Pacing Clin Electrophysiol , vol.29 , pp. 509-511
    • Henrikson, C.A.1    Leng, C.T.2    Yuh, D.D.3
  • 6
    • 0037149716 scopus 로고    scopus 로고
    • Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction
    • Moss AJ, Zareba W, Hall WJ, et al. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med 2002;346:877-83.
    • (2002) N Engl J Med , vol.346 , pp. 877-883
    • Moss, A.J.1    Zareba, W.2    Hall, W.J.3
  • 9
    • 0032803989 scopus 로고    scopus 로고
    • Perforation of the right ventricular free wall by an active fixation transvenous cardioverter defibrillator lead
    • Shohat-Zabarski R, Kusniec J, Strasberg B. Perforation of the right ventricular free wall by an active fixation transvenous cardioverter defibrillator lead. Pacing Clin Electrophysiol 1999;22:1118-9.
    • (1999) Pacing Clin Electrophysiol , vol.22 , pp. 1118-1119
    • Shohat-Zabarski, R.1    Kusniec, J.2    Strasberg, B.3
  • 10
    • 0036692918 scopus 로고    scopus 로고
    • Right pneumothorax resulting from an endocardial screw-in atrial lead in an implantable cardioverter defibrillator system
    • Oginosawa Y, Abe H, Nakashima Y. Right pneumothorax resulting from an endocardial screw-in atrial lead in an implantable cardioverter defibrillator system. Pacing Clin Electrophysiol 2002;25:1278-9.
    • (2002) Pacing Clin Electrophysiol , vol.25 , pp. 1278-1279
    • Oginosawa, Y.1    Abe, H.2    Nakashima, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.