-
1
-
-
0036344113
-
Wine vinegar: technology, authenticity and quality evaluation
-
Tesfaye W., Morales M.L., García-Parrilha M.C., and Troncoso A.M. Wine vinegar: technology, authenticity and quality evaluation. Food Sci. Tech. 3 (2002) 12-21
-
(2002)
Food Sci. Tech.
, vol.3
, pp. 12-21
-
-
Tesfaye, W.1
Morales, M.L.2
García-Parrilha, M.C.3
Troncoso, A.M.4
-
2
-
-
4043123919
-
Determination of lead in vinegar by ICP-MS and GFAAS: evaluation of different sample preparation procedure
-
Ndung'u K., Hibbon S., and Flegal A.R. Determination of lead in vinegar by ICP-MS and GFAAS: evaluation of different sample preparation procedure. Talanta 64 (2004) 258-263
-
(2004)
Talanta
, vol.64
, pp. 258-263
-
-
Ndung'u, K.1
Hibbon, S.2
Flegal, A.R.3
-
3
-
-
2342462220
-
Cadmium and lead determination in foods by beam injection flame furnace atomic absorption spectrometry after ultrasound-assisted sample preparation
-
Aleixo P.C., Júnior D.S., Tomazelli A.C., Rufini I.A., Berndt H., and Krug F.J. Cadmium and lead determination in foods by beam injection flame furnace atomic absorption spectrometry after ultrasound-assisted sample preparation. Anal. Chim. Acta 512 (2004) 329-337
-
(2004)
Anal. Chim. Acta
, vol.512
, pp. 329-337
-
-
Aleixo, P.C.1
Júnior, D.S.2
Tomazelli, A.C.3
Rufini, I.A.4
Berndt, H.5
Krug, F.J.6
-
4
-
-
0035980203
-
Simultaneous determination of cadmium and lead in wine by electrothermal atomic absorption spectrometry
-
Freschi G.P.G., Dakuzaku C.S., de Moraes M., Nóbrega A., and Gomes Neto J.A. Simultaneous determination of cadmium and lead in wine by electrothermal atomic absorption spectrometry. Spectrochim. Acta Part B 56 (2001) 1987-1993
-
(2001)
Spectrochim. Acta Part B
, vol.56
, pp. 1987-1993
-
-
Freschi, G.P.G.1
Dakuzaku, C.S.2
de Moraes, M.3
Nóbrega, A.4
Gomes Neto, J.A.5
-
5
-
-
11144265304
-
Comparison of palladium-magnesium nitrate and ammonium dihydrogenphosphate modifiers for lead determination in honey by electrothermal atomic absorption spectrometry
-
Garcia J.C.R., Garcia J.B., Latorre C.H., Martin S.G., and Crecente R.M.P. Comparison of palladium-magnesium nitrate and ammonium dihydrogenphosphate modifiers for lead determination in honey by electrothermal atomic absorption spectrometry. Food Chem. 91 (2005) 435-442
-
(2005)
Food Chem.
, vol.91
, pp. 435-442
-
-
Garcia, J.C.R.1
Garcia, J.B.2
Latorre, C.H.3
Martin, S.G.4
Crecente, R.M.P.5
-
6
-
-
23044432811
-
Determination of copper, cadmium and lead in seawater and mineral water by flame atomic absorption spectrometry after coprecipitation with aluminum hydroxide
-
Doner G., and Ege A. Determination of copper, cadmium and lead in seawater and mineral water by flame atomic absorption spectrometry after coprecipitation with aluminum hydroxide. Anal. Chim. Acta 547 (2005) 14-17
-
(2005)
Anal. Chim. Acta
, vol.547
, pp. 14-17
-
-
Doner, G.1
Ege, A.2
-
7
-
-
7044249094
-
Continuous flow system for lead determination by FAAS in spirituous beverages with solid phase extraction and on-line copper removal
-
Pena Y.P., Paredes B., Rondon W., Burguera M., Burguera J.L., Rondon C., Carrero P., and Capote T. Continuous flow system for lead determination by FAAS in spirituous beverages with solid phase extraction and on-line copper removal. Talanta 64 (2004) 1351-1358
-
(2004)
Talanta
, vol.64
, pp. 1351-1358
-
-
Pena, Y.P.1
Paredes, B.2
Rondon, W.3
Burguera, M.4
Burguera, J.L.5
Rondon, C.6
Carrero, P.7
Capote, T.8
-
8
-
-
30644459077
-
Simultaneous analysis of cadmium, lead, mercury, and arsenic content in foodstuffs of animal origin by inductively coupled plasma/mass spectrometry after closed vessel microwave digestion: method validation
-
Noel L., Dufaily V., Lemahieu N., Vastel C., and Guerin T. Simultaneous analysis of cadmium, lead, mercury, and arsenic content in foodstuffs of animal origin by inductively coupled plasma/mass spectrometry after closed vessel microwave digestion: method validation. J. AOAC Int. 88 (2005) 1811-1821
-
(2005)
J. AOAC Int.
, vol.88
, pp. 1811-1821
-
-
Noel, L.1
Dufaily, V.2
Lemahieu, N.3
Vastel, C.4
Guerin, T.5
-
9
-
-
23644454107
-
On-line preconcentration/determination of lead in Ilex paraguariensis samples (mate tea) using polyurethane foam as filter and USN-ICP-OES
-
Marchisio P.F., Sales A., Cerutti S., Marchevski E., and Martinez L.D. On-line preconcentration/determination of lead in Ilex paraguariensis samples (mate tea) using polyurethane foam as filter and USN-ICP-OES. J. Hazard. Mater. 124 (2005) 113-118
-
(2005)
J. Hazard. Mater.
, vol.124
, pp. 113-118
-
-
Marchisio, P.F.1
Sales, A.2
Cerutti, S.3
Marchevski, E.4
Martinez, L.D.5
-
10
-
-
3042530939
-
The determination of lead in preserved food by spectrophotometry with dibromohydroxyphenylporphyrin
-
Li Z.J., Tang J.A., and Pan J.M. The determination of lead in preserved food by spectrophotometry with dibromohydroxyphenylporphyrin. Food Control 15 (2004) 565-570
-
(2004)
Food Control
, vol.15
, pp. 565-570
-
-
Li, Z.J.1
Tang, J.A.2
Pan, J.M.3
-
11
-
-
5344224726
-
Heavy metals in matrices of food interest: sequential voltammetric determination at trace and ultratrace level of copper, lead, cadmium, zinc, arsenic, selenium, manganese and iron in meals
-
Locatelli C. Heavy metals in matrices of food interest: sequential voltammetric determination at trace and ultratrace level of copper, lead, cadmium, zinc, arsenic, selenium, manganese and iron in meals. Electroanalysis 16 (2004) 1478-1486
-
(2004)
Electroanalysis
, vol.16
, pp. 1478-1486
-
-
Locatelli, C.1
-
12
-
-
19744372217
-
Comparison of two digestion procedures for the determination of lead in lichens by electrothermal atomic absorption spectrometry
-
Moreira F.R., Borges R.M., and Oliveira R.M. Comparison of two digestion procedures for the determination of lead in lichens by electrothermal atomic absorption spectrometry. Spectrochim. Acta Part B 60 (2005) 775-758
-
(2005)
Spectrochim. Acta Part B
, vol.60
, pp. 775-758
-
-
Moreira, F.R.1
Borges, R.M.2
Oliveira, R.M.3
-
13
-
-
27144534218
-
Determination of lead in water samples by graphite furnace atomic absorption spectrometry after cloud point extraction
-
Chen J.R., Xiao S.M., Wu X.H., Fang K.M., and Liu W.H. Determination of lead in water samples by graphite furnace atomic absorption spectrometry after cloud point extraction. Talanta 67 (2005) 992-996
-
(2005)
Talanta
, vol.67
, pp. 992-996
-
-
Chen, J.R.1
Xiao, S.M.2
Wu, X.H.3
Fang, K.M.4
Liu, W.H.5
-
14
-
-
34248337037
-
Ammonium fluoride as a novel chemical modifier for the elimination of magnesium chloride interference on the determination of lead by graphite furnace atomic absorption spectrometry
-
Husáková L., Šrámková J., Černohorský T., and Bařinová M. Ammonium fluoride as a novel chemical modifier for the elimination of magnesium chloride interference on the determination of lead by graphite furnace atomic absorption spectrometry. Talanta 72 (2007) 1400-1403
-
(2007)
Talanta
, vol.72
, pp. 1400-1403
-
-
Husáková, L.1
Šrámková, J.2
Černohorský, T.3
Bařinová, M.4
-
17
-
-
2542495400
-
1H-NMR studies on Italian balsamic and traditional balsamic vinegars
-
1H-NMR studies on Italian balsamic and traditional balsamic vinegars. J. Agric. Food Chem. 52 (2004) 3446-3450
-
(2004)
J. Agric. Food Chem.
, vol.52
, pp. 3446-3450
-
-
Consonni, R.1
Gatti, A.2
-
18
-
-
0007816588
-
Evaluation of internal standardization in electrothermal atomic absorption spectrometry
-
Radziuk B., Romanova N.P., and Thomassen Y. Evaluation of internal standardization in electrothermal atomic absorption spectrometry. Anal. Commun. 36 (1999) 13-16
-
(1999)
Anal. Commun.
, vol.36
, pp. 13-16
-
-
Radziuk, B.1
Romanova, N.P.2
Thomassen, Y.3
-
19
-
-
0036141915
-
Evaluation and application of bismuth as an internal standard for the determination of lead in wines by simultaneous electrothermal atomic absorption spectrometry
-
Fernandes K.G., Moraes M., Gomes Neto J.A., Nóbrega J.A., and Oliveira P.V. Evaluation and application of bismuth as an internal standard for the determination of lead in wines by simultaneous electrothermal atomic absorption spectrometry. Analyst 127 (2002) 157-162
-
(2002)
Analyst
, vol.127
, pp. 157-162
-
-
Fernandes, K.G.1
Moraes, M.2
Gomes Neto, J.A.3
Nóbrega, J.A.4
Oliveira, P.V.5
-
20
-
-
3242781705
-
Silver as internal standard for simultaneous determination of Cd and Pb in whole blood by electrothermal atomic absorption spectrometry
-
Correia P.R.M., Oliveira P.V., Gomes Neto J.A., and Nóbrega J.A. Silver as internal standard for simultaneous determination of Cd and Pb in whole blood by electrothermal atomic absorption spectrometry. J. Anal. At. Spectrom. 19 (2004) 917-922
-
(2004)
J. Anal. At. Spectrom.
, vol.19
, pp. 917-922
-
-
Correia, P.R.M.1
Oliveira, P.V.2
Gomes Neto, J.A.3
Nóbrega, J.A.4
-
21
-
-
19744376542
-
Internal standardization in graphite furnace atomic absorption spectrometry: comparative use of As and Ge to minimize matrix effects on Se determination in milk
-
Oliveira A.P., Gomes Neto J.A., Nóbrega J.A., and Oliveira P.V. Internal standardization in graphite furnace atomic absorption spectrometry: comparative use of As and Ge to minimize matrix effects on Se determination in milk. Spectrochim. Acta Part B 60 (2005) 681-686
-
(2005)
Spectrochim. Acta Part B
, vol.60
, pp. 681-686
-
-
Oliveira, A.P.1
Gomes Neto, J.A.2
Nóbrega, J.A.3
Oliveira, P.V.4
-
22
-
-
19744363837
-
Arsenic as internal standard to correct for interferences in the determination of antimony by hydride generation in situ trapping graphite furnace atomic absorption spectrometry
-
Freschi C.D., Freschi G.P.G., Gomes Neto J.A., Nóbrega J.A., and Oliveira P.V. Arsenic as internal standard to correct for interferences in the determination of antimony by hydride generation in situ trapping graphite furnace atomic absorption spectrometry. Spectrochim. Acta Part B 60 (2005) 759-763
-
(2005)
Spectrochim. Acta Part B
, vol.60
, pp. 759-763
-
-
Freschi, C.D.1
Freschi, G.P.G.2
Gomes Neto, J.A.3
Nóbrega, J.A.4
Oliveira, P.V.5
-
23
-
-
21344472624
-
Cobalt as internal standard for arsenic and selenium determination in urine by simultaneous atomic absorption spectrometry
-
Correia P.R.M., and Oliveira P.V. Cobalt as internal standard for arsenic and selenium determination in urine by simultaneous atomic absorption spectrometry. Talanta 67 (2005) 46-53
-
(2005)
Talanta
, vol.67
, pp. 46-53
-
-
Correia, P.R.M.1
Oliveira, P.V.2
-
24
-
-
3042660322
-
A chemometric approach to the comparison of different sample treatments for metals determination by atomic absorption spectroscopy in aceto balsamico tradizionale di modena
-
Cochi M., Franchini G., Manzini D., Manfredini M., Marchetti A., and Ulrici A. A chemometric approach to the comparison of different sample treatments for metals determination by atomic absorption spectroscopy in aceto balsamico tradizionale di modena. J. Agric. Food Chem. 52 (2004) 4047-4056
-
(2004)
J. Agric. Food Chem.
, vol.52
, pp. 4047-4056
-
-
Cochi, M.1
Franchini, G.2
Manzini, D.3
Manfredini, M.4
Marchetti, A.5
Ulrici, A.6
-
25
-
-
33645379100
-
Evaluation of Ir, Ru and W as permanent modifiers for the simultaneous determination of As, Bi, Pb, Sb, and Se in natural water by electrothermal atomic absorption spectrometry
-
Freschi G.P.G., Freschi C.D., and Gomes Neto J.A. Evaluation of Ir, Ru and W as permanent modifiers for the simultaneous determination of As, Bi, Pb, Sb, and Se in natural water by electrothermal atomic absorption spectrometry. At. Spectrosc. 27 (2006) 1-6
-
(2006)
At. Spectrosc.
, vol.27
, pp. 1-6
-
-
Freschi, G.P.G.1
Freschi, C.D.2
Gomes Neto, J.A.3
-
26
-
-
0002065076
-
Recent experiences with the stabilized temperature platform furnace and Zeeman background correction
-
Slavin W., Carnrick G.R., Manning D.C., and Pruszkowska E. Recent experiences with the stabilized temperature platform furnace and Zeeman background correction. At. Spectrosc. 4 3 (1983) 69-86
-
(1983)
At. Spectrosc.
, vol.4
, Issue.3
, pp. 69-86
-
-
Slavin, W.1
Carnrick, G.R.2
Manning, D.C.3
Pruszkowska, E.4
-
27
-
-
0001324474
-
Real-time standardization for inductively coupled plasma atomic emission spectrometry using custom segmented-array charge coupled detector
-
Mermet J.M., and Ivaldi J.C. Real-time standardization for inductively coupled plasma atomic emission spectrometry using custom segmented-array charge coupled detector. J. Anal. At. Spectrom. 8 (1993) 795-801
-
(1993)
J. Anal. At. Spectrom.
, vol.8
, pp. 795-801
-
-
Mermet, J.M.1
Ivaldi, J.C.2
-
28
-
-
0033039021
-
Nomenclature in evaluation of analytical methods including detection and quantification capabilities (IUPAC Recommendations 1995)
-
Currie L.A. Nomenclature in evaluation of analytical methods including detection and quantification capabilities (IUPAC Recommendations 1995). Anal. Chim. Acta 391 (1999) 105-126
-
(1999)
Anal. Chim. Acta
, vol.391
, pp. 105-126
-
-
Currie, L.A.1
|