-
1
-
-
0028236279
-
Thrombolysis versus thrombectomy for occluded hemodialysis grafts
-
Schuman E., Quinn S., Standage B., and Gross G. Thrombolysis versus thrombectomy for occluded hemodialysis grafts. Am J Surg 167 (1994) 473-476
-
(1994)
Am J Surg
, vol.167
, pp. 473-476
-
-
Schuman, E.1
Quinn, S.2
Standage, B.3
Gross, G.4
-
2
-
-
0028836806
-
Thrombosed dialysis grafts: comparison of treatment with transluminal angioplasty and surgical revision
-
Schwartz C.I., McBrayer C.V., Sloan J.H., Meneses P., and Ennis W.J. Thrombosed dialysis grafts: comparison of treatment with transluminal angioplasty and surgical revision. Radiology 194 (1995) 337-341
-
(1995)
Radiology
, vol.194
, pp. 337-341
-
-
Schwartz, C.I.1
McBrayer, C.V.2
Sloan, J.H.3
Meneses, P.4
Ennis, W.J.5
-
3
-
-
0029025609
-
Thrombosed hemodialysis grafts: percutaneous mechanical balloon declotting versus thrombolysis
-
Middlebrook M.R., Amygdalos M.A., Soulen M.C., et al. Thrombosed hemodialysis grafts: percutaneous mechanical balloon declotting versus thrombolysis. Radiology 196 (1995) 73-77
-
(1995)
Radiology
, vol.196
, pp. 73-77
-
-
Middlebrook, M.R.1
Amygdalos, M.A.2
Soulen, M.C.3
-
4
-
-
0029553355
-
Thrombolysis versus surgery for the treatment of thrombosed dialysis access grafts
-
Beathard G.A. Thrombolysis versus surgery for the treatment of thrombosed dialysis access grafts. J Am Soc Nephrol 6 (1995) 1619-1624
-
(1995)
J Am Soc Nephrol
, vol.6
, pp. 1619-1624
-
-
Beathard, G.A.1
-
5
-
-
0036847153
-
A metaanalysis comparing surgical thrombectomy, mechanical thrombectomy, and pharmacomechanical thrombolysis for thrombosed dialysis grafts
-
Green L.D., Lee D.S., and Kucey D.S. A metaanalysis comparing surgical thrombectomy, mechanical thrombectomy, and pharmacomechanical thrombolysis for thrombosed dialysis grafts. J Vasc Surg 36 (2002) 939-945
-
(2002)
J Vasc Surg
, vol.36
, pp. 939-945
-
-
Green, L.D.1
Lee, D.S.2
Kucey, D.S.3
-
6
-
-
0030924191
-
Prospective randomized comparison of surgical versus endovascular management of thrombosed dialysis access grafts
-
Marston W.A., Criado E., Jaques P.F., Mauro M.A., Burnham S.J., and Keagy B.A. Prospective randomized comparison of surgical versus endovascular management of thrombosed dialysis access grafts. J Vasc Surg 26 (1997) 373-380
-
(1997)
J Vasc Surg
, vol.26
, pp. 373-380
-
-
Marston, W.A.1
Criado, E.2
Jaques, P.F.3
Mauro, M.A.4
Burnham, S.J.5
Keagy, B.A.6
-
7
-
-
0032762990
-
Endovascular versus surgical treatment for thrombosed hemodialysis grafts: a prospective, randomized study
-
Dougherty M.J., Calligaro K.D., Schindler N., Raviola C.A., and Ntoso A. Endovascular versus surgical treatment for thrombosed hemodialysis grafts: a prospective, randomized study. J Vasc Surg 30 (1999) 1016-1023
-
(1999)
J Vasc Surg
, vol.30
, pp. 1016-1023
-
-
Dougherty, M.J.1
Calligaro, K.D.2
Schindler, N.3
Raviola, C.A.4
Ntoso, A.5
-
8
-
-
1542426312
-
Management of thrombosed dialysis access: thrombectomy versus thrombolysis
-
Bush R.L., Lin P.H., and Lumsden A.B. Management of thrombosed dialysis access: thrombectomy versus thrombolysis. Semin Vasc Surg 17 (2004) 32-39
-
(2004)
Semin Vasc Surg
, vol.17
, pp. 32-39
-
-
Bush, R.L.1
Lin, P.H.2
Lumsden, A.B.3
-
9
-
-
0032200606
-
Surgery versus percutaneous treatment of thrombosed dialysis access grafts: is there a best method?
-
Gelbfish G.A. Surgery versus percutaneous treatment of thrombosed dialysis access grafts: is there a best method?. J Vasc Interv Radiol 9 (1998) 875-877
-
(1998)
J Vasc Interv Radiol
, vol.9
, pp. 875-877
-
-
Gelbfish, G.A.1
-
10
-
-
33845807146
-
KDOQI Clinical Practice Guidelines and Clinical Practice Recommendations for 2006 Updates: Hemodialysis Adequacy, Peritoneal Dialysis Adequacy and Vascular Access
-
National, Kidney Foundation
-
National, Kidney Foundation. KDOQI Clinical Practice Guidelines and Clinical Practice Recommendations for 2006 Updates: Hemodialysis Adequacy, Peritoneal Dialysis Adequacy and Vascular Access. Am J Kidney Dis 48 suppl 1 (2006) S1-S322
-
(2006)
Am J Kidney Dis
, vol.48
, Issue.SUPPL. 1
-
-
-
11
-
-
0029690931
-
Screening for dialysis access graft malfunction: comparison of physical examination with US
-
Trerotola S.O., Scheel P.J., Owe N.R., et al. Screening for dialysis access graft malfunction: comparison of physical examination with US. J Vasc Interv Radiol 7 (1996) 15-20
-
(1996)
J Vasc Interv Radiol
, vol.7
, pp. 15-20
-
-
Trerotola, S.O.1
Scheel, P.J.2
Owe, N.R.3
-
12
-
-
10744228009
-
Physical examination versus normalized pressure ratio for predicting outcomes of hemodialysis access interventions
-
Trerotola S.O., Ponce P., Stavropoulos S.W., et al. Physical examination versus normalized pressure ratio for predicting outcomes of hemodialysis access interventions. J Vasc Interv Radiol 14 (2003) 1387-1394
-
(2003)
J Vasc Interv Radiol
, vol.14
, pp. 1387-1394
-
-
Trerotola, S.O.1
Ponce, P.2
Stavropoulos, S.W.3
-
13
-
-
5444240789
-
Factors associated with access blood flow in native vessel arteriovenous fistulae
-
Tonelli M., Hirsch D.J., Chan C.T., et al. Factors associated with access blood flow in native vessel arteriovenous fistulae. Nephrol Dial Transplant 19 (2004) 2559-2563
-
(2004)
Nephrol Dial Transplant
, vol.19
, pp. 2559-2563
-
-
Tonelli, M.1
Hirsch, D.J.2
Chan, C.T.3
-
14
-
-
0035070047
-
Graft surveillance: venous pressure, access flow, or the combination?
-
Smits J.H., van der Linden J., Hagen E.C., et al. Graft surveillance: venous pressure, access flow, or the combination?. Kidney Int 2001 59 (2001) 1551-1558
-
(2001)
Kidney Int 2001
, vol.59
, pp. 1551-1558
-
-
Smits, J.H.1
van der Linden, J.2
Hagen, E.C.3
-
15
-
-
0035166053
-
Hemodialysis arteriovenous access: detection of stenosis and response to treatment by vascular access blood flow
-
Schwab S.J., Oliver M.J., Suhocki P., and McCann R. Hemodialysis arteriovenous access: detection of stenosis and response to treatment by vascular access blood flow. Kidney Int 59 (2001) 358-362
-
(2001)
Kidney Int
, vol.59
, pp. 358-362
-
-
Schwab, S.J.1
Oliver, M.J.2
Suhocki, P.3
McCann, R.4
-
16
-
-
0029048657
-
Utility of intra-access pressure monitoring in detecting and correcting venous outlet stenoses prior to thrombosis
-
Besarab A., Sullivan K.L., Ross R.P., and Moritz M.J. Utility of intra-access pressure monitoring in detecting and correcting venous outlet stenoses prior to thrombosis. Kidney Int 47 (1995) 1364-1373
-
(1995)
Kidney Int
, vol.47
, pp. 1364-1373
-
-
Besarab, A.1
Sullivan, K.L.2
Ross, R.P.3
Moritz, M.J.4
-
17
-
-
33746913152
-
Access flow after angioplasty predicts subsequent arteriovenous graft survival
-
Murray B.M., Herman A., Mepani B., and Rajczak S. Access flow after angioplasty predicts subsequent arteriovenous graft survival. J Vasc Interv Radiol 17 (2006) 303-308
-
(2006)
J Vasc Interv Radiol
, vol.17
, pp. 303-308
-
-
Murray, B.M.1
Herman, A.2
Mepani, B.3
Rajczak, S.4
-
18
-
-
33747005230
-
Comparison of access blood flow and venous pressure measurements as predictors of arteriovenous graft thrombosis
-
Singh N., Ahmad S., Wienckowski J.R., and Murray B.M. Comparison of access blood flow and venous pressure measurements as predictors of arteriovenous graft thrombosis. J Vasc Access 7 (2006) 66-73
-
(2006)
J Vasc Access
, vol.7
, pp. 66-73
-
-
Singh, N.1
Ahmad, S.2
Wienckowski, J.R.3
Murray, B.M.4
-
19
-
-
30744446466
-
Thresholds for significant decrease in hemodialysis access blood flow
-
Ram S.J., Nassar R., Sharaf R., Magnasco A., Jones S.A., and Paulson W.D. Thresholds for significant decrease in hemodialysis access blood flow. Semin Dial 18 (2005) 558-564
-
(2005)
Semin Dial
, vol.18
, pp. 558-564
-
-
Ram, S.J.1
Nassar, R.2
Sharaf, R.3
Magnasco, A.4
Jones, S.A.5
Paulson, W.D.6
-
20
-
-
33646423536
-
Functional vascular access evaluation after elective intervention for stenosis
-
Roca-Tey R., Samon R., Ibrik O., Martínes-Cercós R., and Viladoms J. Functional vascular access evaluation after elective intervention for stenosis. J Vasc Access 7 (2006) 29-34
-
(2006)
J Vasc Access
, vol.7
, pp. 29-34
-
-
Roca-Tey, R.1
Samon, R.2
Ibrik, O.3
Martínes-Cercós, R.4
Viladoms, J.5
-
21
-
-
0033777740
-
Predictive value of access blood flow and stenosis in detection of graft failure
-
Wang E., Schneditz D., and Levin N.W. Predictive value of access blood flow and stenosis in detection of graft failure. Clin Nephrol 54 (2000) 393-399
-
(2000)
Clin Nephrol
, vol.54
, pp. 393-399
-
-
Wang, E.1
Schneditz, D.2
Levin, N.W.3
-
22
-
-
33749001183
-
The use of covered nitinol stents to salvage dialysis grafts after multiple failures
-
Naoum J.J., Irwin C., and Hunter G.C. The use of covered nitinol stents to salvage dialysis grafts after multiple failures. Vasc Endovasc Surg 40 (2006) 275-279
-
(2006)
Vasc Endovasc Surg
, vol.40
, pp. 275-279
-
-
Naoum, J.J.1
Irwin, C.2
Hunter, G.C.3
-
23
-
-
0036377414
-
Covered stent exclusion of dialysis access pseudoaneurysms
-
Najibi S., Bush R.L., Terramani T.T., et al. Covered stent exclusion of dialysis access pseudoaneurysms. J Surg Res 106 (2002) 15-19
-
(2002)
J Surg Res
, vol.106
, pp. 15-19
-
-
Najibi, S.1
Bush, R.L.2
Terramani, T.T.3
-
24
-
-
0037377814
-
Using a covered stent (Wallgraft) to treat pseudoaneurysms of dialysis grafts and fistulas
-
Ryan J.M., Dumbleton S.A., Doherty J., and Smith T.P. Using a covered stent (Wallgraft) to treat pseudoaneurysms of dialysis grafts and fistulas. AJR Am J Roentgenol 180 (2003) 1067-1071
-
(2003)
AJR Am J Roentgenol
, vol.180
, pp. 1067-1071
-
-
Ryan, J.M.1
Dumbleton, S.A.2
Doherty, J.3
Smith, T.P.4
-
25
-
-
26844499797
-
Use of stent grafts to repair hemodialysis graft-related pseudoaneurysms
-
Vesely T.M. Use of stent grafts to repair hemodialysis graft-related pseudoaneurysms. J Vasc Interv Radiol 16 (2005) 1301-1307
-
(2005)
J Vasc Interv Radiol
, vol.16
, pp. 1301-1307
-
-
Vesely, T.M.1
-
26
-
-
23844439889
-
Dialysis needle puncture of Wallgrafts placed in polytetrafluoroethylene hemodialysis grafts
-
Rhodes E.S., and Silas A.M. Dialysis needle puncture of Wallgrafts placed in polytetrafluoroethylene hemodialysis grafts. J Vasc Interv Radiol 16 (2005) 1129-1134
-
(2005)
J Vasc Interv Radiol
, vol.16
, pp. 1129-1134
-
-
Rhodes, E.S.1
Silas, A.M.2
|