메뉴 건너뛰기




Volumn 22, Issue 8, 2007, Pages 185-190

New method to calculate the steady-state temperature field and ampacity of underground cable system

Author keywords

Ampacity; Cable system; FEM; Harmonic mean method; Subtense truncation approach; Temperature field; Thermal circuit method

Indexed keywords

FINITE ELEMENT METHOD; TEMPERATURE;

EID: 34548637031     PISSN: 10006753     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (68)

References (16)
  • 1
    • 34548615122 scopus 로고
    • The temperature rise of buried cables and pipes
    • New York, The United States
    • Neher J H. The temperature rise of buried cables and pipes[C]. AIEE Winter General Meeting, New York, The United States, 1949, 49(2): 9-16.
    • (1949) AIEE Winter General Meeting , vol.49 , Issue.2 , pp. 9-16
    • Neher, J.H.1
  • 2
    • 84944376193 scopus 로고
    • The calculation of the temperature rise and load capability of cable systems
    • Montreal, Canada
    • Neher J H, Mcgrath M H. The calculation of the temperature rise and load capability of cable systems[C]. AIEE Summer General Meeting, Montreal, Canada, 1957: 57-660, 752-772.
    • (1957) AIEE Summer General Meeting
    • Neher, J.H.1    Mcgrath, M.H.2
  • 3
    • 34548637032 scopus 로고    scopus 로고
    • Calculation of the current rating - Part 1: Current rating equations (100% load factor) and calculation of losses
    • IEC 60287-1
    • IEC 60287-1. Calculation of the Current Rating-Part 1: Current Rating Equations (100% Load Factor) and Calculation of Losses[S]. 2001.
    • (2001)
  • 4
    • 34548646938 scopus 로고    scopus 로고
    • Calculation of the current rating - Part 2: Thermal resistance
    • IEC 60287-2
    • IEC 60287-2. Calculation of the Current Rating-Part 2: Thermal Resistance[S]. 2001.
    • (2001)
  • 5
    • 34548651751 scopus 로고    scopus 로고
    • Calculation of the current rating - Part 3: Sections on operating conditions
    • IEC 60287-3
    • IEC 60287-3. Calculation of the Current Rating-Part 3: Sections on Operating Conditions[S]. 1999.
    • (1999)
  • 7
    • 0043212275 scopus 로고    scopus 로고
    • Numerical computation of temperature distribution of underground cables and soil with combinatorial coordinates
    • Cao Huiling, Wang Zengqiang, Li Wenjing, et al. Numerical computation of temperature distribution of underground cables and soil with combinatorial coordinates[J]. Transactions of China Electrotechnical Society, 2003, 18(3): 59-63.
    • (2003) Transactions of China Electrotechnical Society , vol.18 , Issue.3 , pp. 59-63
    • Cao, H.1    Wang, Z.2    Li, W.3
  • 8
    • 0038749237 scopus 로고    scopus 로고
    • A study of transient thermal circuit model for the cable transformer coil based on finite element method
    • Fu Chenzhao, Ji Shengchang, Wang Shishan, et al. A study of transient thermal circuit model for the cable transformer coil based on finite element method[J]. Transactions of China Electrotechnical Society, 2003, 18(2): 77-82.
    • (2003) Transactions of China Electrotechnical Society , vol.18 , Issue.2 , pp. 77-82
    • Fu, C.1    Ji, S.2    Wang, S.3
  • 11
    • 0036706807 scopus 로고    scopus 로고
    • Calculation of nonlinear stator temperature field for generator based on hybrid boundary conditions
    • Cheng Shukang, Li Weili, Hou Yunpeng. Calculation of nonlinear stator temperature field for generator based on hybrid boundary conditions[J]. Transactions of China Electrotechnical Society, 2002, 17(4): 1-6.
    • (2002) Transactions of China Electrotechnical Society , vol.17 , Issue.4 , pp. 1-6
    • Cheng, S.1    Li, W.2    Hou, Y.3
  • 12
    • 3042739630 scopus 로고    scopus 로고
    • Design and analysis of new type air-core reactor based on coupled fluid-thermal field calculation
    • Liu Zhigang, Geng Yingsan, Wang Jianhua, et al. Design and analysis of new type air-core reactor based on coupled fluid-thermal field calculation[J]. Transactions of China Electrotechnical Society, 2003, 18(6): 59-63.
    • (2003) Transactions of China Electrotechnical Society , vol.18 , Issue.6 , pp. 59-63
    • Liu, Z.1    Geng, Y.2    Wang, J.3
  • 13
    • 34548639573 scopus 로고    scopus 로고
    • in Chinese
  • 14
    • 34548640495 scopus 로고    scopus 로고
    • in Chinese
  • 15
    • 0030189958 scopus 로고    scopus 로고
    • Proximity effect and eddy currency losses in insulated cables
    • Ferkal K, Poloujadoff M. Proximity effect and eddy currency losses in insulated cables[J]. IEEE Transactions on Power Delivery, 1996, 11(3): 1171-1178.
    • (1996) IEEE Transactions on Power Delivery , vol.11 , Issue.3 , pp. 1171-1178
    • Ferkal, K.1    Poloujadoff, M.2
  • 16
    • 2942525146 scopus 로고    scopus 로고
    • Numerical calculations of internal impedance of cylindrical conductors
    • Wu Mingli, Fan Yu. Numerical calculations of internal impedance of cylindrical conductors[J]. Transactions of China Electrotechnical Society, 2004, 19(3): 52-58.
    • (2004) Transactions of China Electrotechnical Society , vol.19 , Issue.3 , pp. 52-58
    • Wu, M.1    Fan, Y.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.