Volumn 30, Issue 7, 2007, Pages 1143-1152

Experimental thermal performance study of an inclined heat pipe heat exchanger operating in high humid tropical HVAC systems

Author keywords

Air conditioning; Air cooler; Condensation; Efficiency; Experiment; Geometry; Heat exchanger; Heat pipe; Relative humidity

Indexed keywords

AIR CONDITIONING; ATMOSPHERIC HUMIDITY; CONDENSATION; COOLING SYSTEMS; EVAPORATORS; VENTILATION;

EID: 34548595588     PISSN: 01407007     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrefrig.2007.03.002     Document Type: Article
Times cited : (29)

References (13)
  • 1
    • 33751181655 scopus 로고    scopus 로고
    • Application of a heat pipe heat exchanger to dehumidification enhancement in tropical HVAC systems - a baseline performance characteristics study
    • (Elsevier Science Ltd.)
    • Yau Y.H. Application of a heat pipe heat exchanger to dehumidification enhancement in tropical HVAC systems - a baseline performance characteristics study. International Journal of Thermal Sciences 46 2 (2007) 164-171 (Elsevier Science Ltd.)
    • (2007) International Journal of Thermal Sciences , vol.46 , Issue.2 , pp. 164-171
    • Yau, Y.H.1
  • 2
    • 0025994555 scopus 로고
    • Characteristics of a gravity-assisted heat pipe-based heat exchanger
    • (Pergamon Press Ltd., Great Britain)
    • Wadowski T., Akbarzadeh A., and Johnson P. Characteristics of a gravity-assisted heat pipe-based heat exchanger. Heat Recovery Systems & CHP 11 1 (1991) 69-77 (Pergamon Press Ltd., Great Britain)
    • (1991) Heat Recovery Systems & CHP , vol.11 , Issue.1 , pp. 69-77
    • Wadowski, T.1    Akbarzadeh, A.2    Johnson, P.3
  • 3
    • 0028695804 scopus 로고
    • The use of heat pipe heat exchangers for enhanced dehumidification
    • Proceedings of the ASHRAE Winter Meeting, January 23-26 1994, New Orleans, LA, USA
    • Hill J.M., and Jeter S.M. The use of heat pipe heat exchangers for enhanced dehumidification. Proceedings of the ASHRAE Winter Meeting, January 23-26 1994, New Orleans, LA, USA. ASHRAE Transactions 100 1 (1994) 91-102
    • (1994) ASHRAE Transactions , vol.100 , Issue.1 , pp. 91-102
    • Hill, J.M.1    Jeter, S.M.2
  • 4
    • 0031699376 scopus 로고    scopus 로고
    • A testing and HVAC design methodology for air-to-air heat pipe heat exchangers
    • Guo P., Ciepliski D.L., and Besant R.W. A testing and HVAC design methodology for air-to-air heat pipe heat exchangers. International Journal of HVAC&R Research 4 1 (January 1998) 3-26
    • (1998) International Journal of HVAC&R Research , vol.4 , Issue.1 , pp. 3-26
    • Guo, P.1    Ciepliski, D.L.2    Besant, R.W.3
  • 5
    • 0030408496 scopus 로고    scopus 로고
    • K. Beckert, H. Herwig, Inclined air-to-air heat exchangers with heat pipes: comparing experimental data with theoretical results, in: Proceedings of the 31st Intersociety Energy Conversion Engineering Conference, IECEC 96, August 11-16, Washington, DC, USA, Part 2 (of 4), vol. 2, 1996, pp. 1441-1446.
  • 6
    • 34548596717 scopus 로고    scopus 로고
    • N.W. Foot, K.L. Wallace, A.G. Williamson, A flat plate heat pipe solar panel, in: Proceedings of Chemica'81 - the Nineth Aust. Conf. on Chem. Eng., Christchurch, 1981, pp. 699-705.
  • 7
    • 34548583285 scopus 로고    scopus 로고
    • L.H. Hua, A Flat Plate Heat Pipe Solar Panel, Master thesis Research, Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand, 2003.
  • 10
    • 34548552709 scopus 로고    scopus 로고
    • A.S. Tucker, On screen psychrometric chart, Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand.
  • 11
    • 34548585156 scopus 로고    scopus 로고
    • ASHRAE, ASHRAE Handbook Fundamentals SI Edition. Atlanta, GA 30329, USA, 2005, pp. 6.1-6.17.
  • 12
    • 34548570072 scopus 로고    scopus 로고
    • R.C. Prager, T.H. Sun, The analysis of heat transfer with and without condensation in a heat pipe heat exchanger, in: Heat Transfer Division, ASME, Winter Annual Meeting, San Francisco, CA, New York, USA, December 10-15, 1978, pp. 1-7.
  • 13
    • 34548577011 scopus 로고    scopus 로고
    • Y.H. Yau, Energy Savings in Tropical HVAC Systems using Heat Pipe Heat Exchangers, Ph.D. in Mechanical Engineering thesis, Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand, 2004.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.