메뉴 건너뛰기




Volumn 10, Issue 3, 2007, Pages 158-164

Development of a miniature motor-driven pulsatile LVAD driven by a fuzzy controller

Author keywords

Active filling; Artificial heart; Ball screw; Fuzzy; LVAD

Indexed keywords

BORON; IRON; NEODYMIUM; SILASTIC;

EID: 34548573519     PISSN: 14347229     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10047-007-0380-5     Document Type: Article
Times cited : (7)

References (12)
  • 3
    • 0037296007 scopus 로고    scopus 로고
    • Non-invasive flow estimation in an implantable rotary blood pump: A study considering non-pulsatile and pulsatile flows
    • PJ Ayre NH Lovell JC Woodard 2003 Non-invasive flow estimation in an implantable rotary blood pump: a study considering non-pulsatile and pulsatile flows Physiol Meas 24 179 189
    • (2003) Physiol Meas , vol.24 , pp. 179-189
    • Ayre, P.J.1    Lovell, N.H.2    Woodard, J.C.3
  • 5
    • 0036630618 scopus 로고    scopus 로고
    • Sensorless estimation of pressure head and flow of a continuous flow artificial heart based on input power and rotational speed
    • 4
    • M Yoshizawa T Sato A Tanaka K Abe H Takeda T Yambe S Nitta Y Nose 2002 Sensorless estimation of pressure head and flow of a continuous flow artificial heart based on input power and rotational speed ASAIO J 48 4 443 448
    • (2002) ASAIO J , vol.48 , pp. 443-448
    • Yoshizawa, M.1    Sato, T.2    Tanaka, A.3    Abe, K.4    Takeda, H.5    Yambe, T.6    Nitta, S.7    Nose, Y.8
  • 6
    • 0028561834 scopus 로고
    • Development of a compact, highly efficient totally implantable motor-driven assist pump system
    • E Okamoto K Tomoda K Yamamoto Y Mitamura T Mikami 1994 Development of a compact, highly efficient totally implantable motor-driven assist pump system Artif Organs 18 911 917
    • (1994) Artif Organs , vol.18 , pp. 911-917
    • Okamoto, E.1    Tomoda, K.2    Yamamoto, K.3    Mitamura, Y.4    Mikami, T.5
  • 7
    • 0141926542 scopus 로고    scopus 로고
    • Design of a miniature implantable left ventricular assist device using CAD/CAM technology
    • E Okamoto T Hashimoto Y Mitamura 2003 Design of a miniature implantable left ventricular assist device using CAD/CAM technology J Artif Organs 6 162 167
    • (2003) J Artif Organs , vol.6 , pp. 162-167
    • Okamoto, E.1    Hashimoto, T.2    Mitamura, Y.3
  • 12
    • 0037880474 scopus 로고    scopus 로고
    • Newly developed ventricular assist device with linear oscillatory actuator
    • K Fukunaga A Funakubo Y Fukui 2003 Newly developed ventricular assist device with linear oscillatory actuator ASAIO J 49 333 339
    • (2003) ASAIO J , vol.49 , pp. 333-339
    • Fukunaga, K.1    Funakubo, A.2    Fukui, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.