메뉴 건너뛰기




Volumn 212, Issue 2, 2007, Pages 223-230

A detailed 3D model of the guinea pig cochlea

Author keywords

3D modeling; Cochlea; Reconstruction; Registration; Segmentation; Virtual endoscope; Visualization

Indexed keywords

ANIMAL EXPERIMENT; ARTICLE; COCHLEA; COCHLEA DUCT; COCHLEA PROSTHESIS; COCHLEAR NERVE; COMPUTER PROGRAM; CONTROLLED STUDY; FUNCTIONAL ANATOMY; GUINEA PIG; HAIR CELL; HISTOCHEMISTRY; HISTOLOGY; MODEL; NEUROANATOMY; NEUROIMAGING; NONHUMAN; PHOTOGRAPHY; PRIORITY JOURNAL; SIMULATION; SPIRAL GANGLION; THREE DIMENSIONAL IMAGING;

EID: 34548567818     PISSN: 18632653     EISSN: 18632661     Source Type: Journal    
DOI: 10.1007/s00429-007-0146-0     Document Type: Article
Times cited : (15)

References (26)
  • 1
    • 0029813674 scopus 로고    scopus 로고
    • Visualization of inner ear structures by three-dimensional high-resolution magnetic resonance imaging
    • 3
    • Barbara A, Lorenz J, Gerd G (1996) Visualization of inner ear structures by three-dimensional high-resolution magnetic resonance imaging. Am J Otol 17(3):480-485
    • (1996) Am J Otol , vol.17 , pp. 480-485
    • Barbara, A.1    Lorenz, J.2    Gerd, G.3
  • 2
    • 0030815317 scopus 로고    scopus 로고
    • Submillimeter imaging and reconstruction of the inner ear
    • 6 suppl
    • Dahm MC, Mack MG, Tykocinski M et al (1997) Submillimeter imaging and reconstruction of the inner ear. Am J Otol 18(6 suppl):S54-S56
    • (1997) Am J Otol , vol.18
    • Dahm, M.C.1    MacK, M.G.2    Tykocinski, M.3
  • 3
    • 0033031565 scopus 로고    scopus 로고
    • Three-dimensional computational reconstruction of mixed anatomical tissues following histological preparation
    • 2
    • Ferguson SJ, Bryant JT, Ito K (1999) Three-dimensional computational reconstruction of mixed anatomical tissues following histological preparation. Med Eng Phys 21(2):111-117
    • (1999) Med Eng Phys , vol.21 , pp. 111-117
    • Ferguson, S.J.1    Bryant, J.T.2    Ito, K.3
  • 4
    • 0036801687 scopus 로고    scopus 로고
    • Limits to magnetic resonance microscopy
    • Glover P, Mansfield SP (2002) Limits to magnetic resonance microscopy. Rep Prog Phys 65:1489-1511
    • (2002) Rep Prog Phys , vol.65 , pp. 1489-1511
    • Glover, P.1    Mansfield, S.P.2
  • 5
    • 0023839359 scopus 로고
    • Computer-aided three-dimensional reconstruction and morphometry of the outer hair cells of the guinea pig cochlea
    • 1-2
    • Hashimoto S, Kimura RS (1988) Computer-aided three-dimensional reconstruction and morphometry of the outer hair cells of the guinea pig cochlea. Acta Otolaryngol 105(1-2):64-74
    • (1988) Acta Otolaryngol , vol.105 , pp. 64-74
    • Hashimoto, S.1    Kimura, R.S.2
  • 6
    • 0025058243 scopus 로고
    • Computer-aided three-dimensional reconstruction of the inner hair cells and their nerve endings in the guinea pig cochlea
    • 3-4
    • Hashimoto S, Kimura RS, Takasaka T (1990) Computer-aided three-dimensional reconstruction of the inner hair cells and their nerve endings in the guinea pig cochlea. Acta Otolaryngol 109(3-4):228-234
    • (1990) Acta Otolaryngol , vol.109 , pp. 228-234
    • Hashimoto, S.1    Kimura, R.S.2    Takasaka, T.3
  • 7
    • 0028816624 scopus 로고
    • Spiral CT of the temporal bone: Value of image reconstruction at submillimetric table increments
    • Hermans R, Marchal G, Feenstra L et al (1995) Spiral CT of the temporal bone: value of image reconstruction at submillimetric table increments. Neuroradiology 37:150-154
    • (1995) Neuroradiology , vol.37 , pp. 150-154
    • Hermans, R.1    Marchal, G.2    Feenstra, L.3
  • 8
    • 0029804846 scopus 로고    scopus 로고
    • Three-dimensional imaging of temporal bone using a helical CT scan and its application in patients with cochlear implantation
    • 6
    • Himi T, Kataura A, Sakata M et al (1996) Three-dimensional imaging of temporal bone using a helical CT scan and its application in patients with cochlear implantation. J Otorhinolaryngol Relat Spec 58(6):298-300
    • (1996) J Otorhinolaryngol Relat Spec , vol.58 , pp. 298-300
    • Himi, T.1    Kataura, A.2    Sakata, M.3
  • 9
    • 0031805893 scopus 로고    scopus 로고
    • Measurement of guinea pig basilar membrane using computer-aided three-dimensional reconstruction system
    • 1-2
    • Hiroshi W, Sugawara M, Kobayashi T et al (1998) Measurement of guinea pig basilar membrane using computer-aided three-dimensional reconstruction system. Hear Res 120(1-2):1-6
    • (1998) Hear Res , vol.120 , pp. 1-6
    • Hiroshi, W.1    Sugawara, M.2    Kobayashi, T.3
  • 10
    • 0032924568 scopus 로고    scopus 로고
    • Multi-slice helical CT scan and reconstruction
    • Hu H (1999) Multi-slice helical CT scan and reconstruction. Med Phys 26:5-18
    • (1999) Med Phys , vol.26 , pp. 5-18
    • Hu, H.1
  • 11
    • 0030727436 scopus 로고    scopus 로고
    • Minute findings of inner ear anomalies by three-dimensional CT scanning
    • Isono M, Murata K, Aiba K et al (1997) Minute findings of inner ear anomalies by three-dimensional CT scanning. Int J Pediatr Otorhinolaryngol 42:41-53
    • (1997) Int J Pediatr Otorhinolaryngol , vol.42 , pp. 41-53
    • Isono, M.1    Murata, K.2    Aiba, K.3
  • 13
    • 0024539207 scopus 로고
    • Computer-generated three-dimensional reconstruction of the cochlea
    • 2
    • Laurence A, Frank R, Raymond H et al (1989) Computer-generated three-dimensional reconstruction of the cochlea. Otolaryngol Head Neck Surg 100(2):87-91
    • (1989) Otolaryngol Head Neck Surg , vol.100 , pp. 87-91
    • Laurence, A.1    Frank, R.2    Raymond, H.3
  • 14
    • 0036834177 scopus 로고    scopus 로고
    • Three-dimensional fast recovery fast spin-echo imaging of the inner ear and the vestibulocochlear nerve
    • 11
    • Nakashima K, Morikawa M, Ishimaru H et al (2002) Three-dimensional fast recovery fast spin-echo imaging of the inner ear and the vestibulocochlear nerve. Eur Radiol 12(11):2776-2780
    • (2002) Eur Radiol , vol.12 , pp. 2776-2780
    • Nakashima, K.1    Morikawa, M.2    Ishimaru, H.3
  • 15
    • 1842557805 scopus 로고    scopus 로고
    • A new method for imaging and 3D reconstruction of mammalian cochlea by fluorescent confocal microscopy
    • Natalie A, Glen, Edwin W (2004) A new method for imaging and 3D reconstruction of mammalian cochlea by fluorescent confocal microscopy. Brain Res 1000:200-210
    • (2004) Brain Res , vol.1000 , pp. 200-210
    • Natalie, A.1    Glen2    Edwin, W.3
  • 16
    • 0034088757 scopus 로고    scopus 로고
    • High-resolution magnetic resonance and volume rendering of the labyrinth
    • Neri E, Caramella D, Cosottini M et al (2000) High-resolution magnetic resonance and volume rendering of the labyrinth. Eur Radiol 10:114-118
    • (2000) Eur Radiol , vol.10 , pp. 114-118
    • Neri, E.1    Caramella, D.2    Cosottini, M.3
  • 17
    • 0036935624 scopus 로고    scopus 로고
    • 3D visualisation of the middle ear and adjacent structures using reconstructed multi-slice CT datasets, correlating 3D images and virtual endoscopy to the 2D cross-sectional images
    • Ratiu P, Becker H, Bartling S et al (2002) 3D visualisation of the middle ear and adjacent structures using reconstructed multi-slice CT datasets, correlating 3D images and virtual endoscopy to the 2D cross-sectional images. Head Neck Radiol 44:783-790
    • (2002) Head Neck Radiol , vol.44 , pp. 783-790
    • Ratiu, P.1    Becker, H.2    Bartling, S.3
  • 18
    • 0029816182 scopus 로고    scopus 로고
    • Anatomy of the temporal bone: Detailed three-dimensional display based on image data from high-resolution helical CT: A preliminary report
    • 3
    • Reisser C, Schubert O, Forsting M et al (1996) Anatomy of the temporal bone: detailed three-dimensional display based on image data from high-resolution helical CT: a preliminary report. Am J Otol 17(3):473-479
    • (1996) Am J Otol , vol.17 , pp. 473-479
    • Reisser, C.1    Schubert, O.2    Forsting, M.3
  • 19
    • 0029840469 scopus 로고    scopus 로고
    • Applying very high resolution microfocus X-ray CT and 3D reconstruction to the human auditory apparatus
    • Shibata T, Nagano T (1996) Applying very high resolution microfocus X-ray CT and 3D reconstruction to the human auditory apparatus. Nat Med 2:933-935
    • (1996) Nat Med , vol.2 , pp. 933-935
    • Shibata, T.1    Nagano, T.2
  • 20
    • 0031700544 scopus 로고    scopus 로고
    • The visible human dataset: The anatomical platform for human simulation
    • 2
    • Spitzer VM, Whitlock DG (1998) The visible human dataset: the anatomical platform for human simulation. Anat Rec 253(2):49-57
    • (1998) Anat Rec , vol.253 , pp. 49-57
    • Spitzer, V.M.1    Whitlock, D.G.2
  • 21
    • 0025342416 scopus 로고
    • Computer-aided 3d temporal bone anatomy for cochlea implant surgery
    • 4
    • Takahashi H, Isamu S (1990) Computer-aided 3d temporal bone anatomy for cochlea implant surgery. Laryngoscope 100(4):417-421
    • (1990) Laryngoscope , vol.100 , pp. 417-421
    • Takahashi, H.1    Isamu, S.2
  • 22
    • 0025221992 scopus 로고
    • Computer-aided three-dimensional reconstruction and measurement for multiple-electrode cochlear implant
    • 12
    • Takahashi H, Isamu S, Akira T (1990) Computer-aided three-dimensional reconstruction and measurement for multiple-electrode cochlear implant. Laryngoscope 100(12):1319-1322
    • (1990) Laryngoscope , vol.100 , pp. 1319-1322
    • Takahashi, H.1    Isamu, S.2    Akira, T.3
  • 23
    • 0032879483 scopus 로고    scopus 로고
    • Cochlear fluid space dimensions for six species derived from reconstructions of 3D magnetic resonance images
    • Thorne M, Salt AN, DeMott JE et al (1999) Cochlear fluid space dimensions for six species derived from reconstructions of 3D magnetic resonance images. Laryngoscope 109:1661-1668
    • (1999) Laryngoscope , vol.109 , pp. 1661-1668
    • Thorne, M.1    Salt, A.N.2    Demott, J.E.3
  • 24
    • 0141453612 scopus 로고    scopus 로고
    • Growth curves, measurement and three-dimensional reconstruction in the histopathology of temporal bones
    • 12
    • Viktor, Chroboka, Milan et al (2002) Growth curves, measurement and three-dimensional reconstruction in the histopathology of temporal bones. Otorhinolaryngol Nova 3(12):109-118
    • (2002) Otorhinolaryngol Nova , vol.3 , pp. 109-118
    • Viktor1    Chroboka2    Milan3
  • 25
    • 0027665215 scopus 로고
    • A three-dimensional reconstruction of the temporal bone by the helical scanning CT and its clinical application
    • 9
    • Yonekawa H, Ohashi M, Miyashita S et al (1993) A three-dimensional reconstruction of the temporal bone by the helical scanning CT and its clinical application. Nippon Jibiinkoka Gakkai Kaiho 96(9):1465-1470
    • (1993) Nippon Jibiinkoka Gakkai Kaiho , vol.96 , pp. 1465-1470
    • Yonekawa, H.1    Ohashi, M.2    Miyashita, S.3
  • 26
    • 34548564529 scopus 로고    scopus 로고
    • The research of vital technology for VCH
    • 3
    • Yuan L, Huang WH, Tang L et al (2003) The research of vital technology for VCH. Acta Anatomica Sinica 34(3):225-230
    • (2003) Acta Anatomica Sinica , vol.34 , pp. 225-230
    • Yuan, L.1    Huang, W.H.2    Tang, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.