메뉴 건너뛰기




Volumn 21, Issue 9, 2007, Pages 1212-1219

Spectral characteristics of longitudinal corneal apex velocities and their relation to the cardiopulmonary system

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; BLOOD FLOW VELOCITY; CARDIOPULMONARY HEMODYNAMICS; CORNEA REFLEX; CORRELATION ANALYSIS; ELECTROCARDIOGRAPHY; EYE MOVEMENT; FREQUENCY ANALYSIS; HUMAN; INTRAOCULAR PRESSURE; KERATOSCOPY; NON INVASIVE MEASUREMENT;

EID: 34548541760     PISSN: 0950222X     EISSN: 14765454     Source Type: Journal    
DOI: 10.1038/sj.eye.6702578     Document Type: Article
Times cited : (32)

References (39)
  • 3
    • 0018816537 scopus 로고
    • Noninvasive evaluation of the carotid bruit
    • Barnes RW. Noninvasive evaluation of the carotid bruit. Annu Rev Med 1980; 31: 201-218.
    • (1980) Annu Rev Med , vol.31 , pp. 201-218
    • Barnes, R.W.1
  • 4
    • 0022368547 scopus 로고
    • The ocular pulse and intraocular pressure as a screening test for carotid artery stenosis
    • Perkins ES. The ocular pulse and intraocular pressure as a screening test for carotid artery stenosis. Br J Ophthalmol 1985; 69: 676-680.
    • (1985) Br J Ophthalmol , vol.69 , pp. 676-680
    • Perkins, E.S.1
  • 5
    • 0028346236 scopus 로고
    • Ocular pulse measurements to assess pulsatile blood flow in carotid artery disease
    • Claridge KG, James CB. Ocular pulse measurements to assess pulsatile blood flow in carotid artery disease. Br J Ophthalmol 1994; 78 321-323.
    • (1994) Br J Ophthalmol , vol.78 , pp. 321-323
    • Claridge, K.G.1    James, C.B.2
  • 7
    • 0015611017 scopus 로고
    • Noninvasive detection and evaluation of carotid occlusive disease
    • Kartchner MM, McRae LP, Morrison FD. Noninvasive detection and evaluation of carotid occlusive disease. Arch Surg 1973; 106 528-535.
    • (1973) Arch Surg , vol.106 , pp. 528-535
    • Kartchner, M.M.1    McRae, L.P.2    Morrison, F.D.3
  • 8
    • 2942596237 scopus 로고    scopus 로고
    • Intraocular pressure and ocular pulse amplitude using dynamic contour tonometry and contact lens tonometry
    • Hoffmann EM, Grus F-H, Pfeiffer N. Intraocular pressure and ocular pulse amplitude using dynamic contour tonometry and contact lens tonometry. BMC Ophthalmol 2004; 4: 1:4.
    • (2004) BMC Ophthalmol , vol.4 , Issue.1 , pp. 4
    • Hoffmann, E.M.1    Grus, F.-H.2    Pfeiffer, N.3
  • 9
    • 0034777901 scopus 로고    scopus 로고
    • Reproducibility of measurement of ocular pulse amplitude and intraocular pressure using Smartlens
    • Vogel A, Beck S, Schwenn O, Grus F, Krummenauer F, Pfeiffer N. Reproducibility of measurement of ocular pulse amplitude and intraocular pressure using Smartlens. Der Ophthalmol 2001; 98: 944-949.
    • (2001) Der Ophthalmol , vol.98 , pp. 944-949
    • Vogel, A.1    Beck, S.2    Schwenn, O.3    Grus, F.4    Krummenauer, F.5    Pfeiffer, N.6
  • 10
    • 0017368306 scopus 로고
    • A no-touch ocular pulse measurement system for the diagnosis of carotid occlusions
    • Northrop RB, Nitakhe SS. A no-touch ocular pulse measurement system for the diagnosis of carotid occlusions. IEEE Trans Biomed Eng 1977; 24: 139-148.
    • (1977) IEEE Trans Biomed Eng , vol.24 , pp. 139-148
    • Northrop, R.B.1    Nitakhe, S.S.2
  • 12
    • 0027438364 scopus 로고
    • Orbital color Doppler imaging
    • Aburn NS. Orbital color Doppler imaging. Eye 1993; 7: 639-647.
    • (1993) Eye , vol.7 , pp. 639-647
    • Aburn, N.S.1
  • 16
    • 0027389405 scopus 로고
    • Amplitude of the ocular pneumoplethysmography waveform is correlated with cardiac output
    • Bosley TM, Cohen MS, Gee W, Reed III J, Sergott RC, Savino PJ. Amplitude of the ocular pneumoplethysmography waveform is correlated with cardiac output. Stroke 1993; 24: 6-9.
    • (1993) Stroke , vol.24 , pp. 6-9
    • Bosley, T.M.1    Cohen, M.S.2    Gee, W.3    Reed III, J.4    Sergott, R.C.5    Savino, P.J.6
  • 17
    • 0001988351 scopus 로고
    • The relationship between pressure and volume changes in living and dead rabbit eyes
    • Eisenlohr JE, Langham ME. The relationship between pressure and volume changes in living and dead rabbit eyes. Invest Ophthalmol 1962; 1: 63-77.
    • (1962) Invest Ophthalmol , vol.1 , pp. 63-77
    • Eisenlohr, J.E.1    Langham, M.E.2
  • 18
    • 0027320151 scopus 로고
    • Measurement of elastic modulus of the bovine cornea by means of holographic interferometry. Part 1. Method and experiment
    • Kasprzak H, Forster W, von Bally G. Measurement of elastic modulus of the bovine cornea by means of holographic interferometry. Part 1. Method and experiment. Opt Vision Sci 1993; 70: 535-544.
    • (1993) Opt Vision Sci , vol.70 , pp. 535-544
    • Kasprzak, H.1    Forster, W.2    von Bally, G.3
  • 19
    • 0028014575 scopus 로고
    • Measurement of elastic modulus of the central bovine cornea by means of holographic interferometry. Part II. Results
    • Forster W, Kasprzak H, von Bally G. Measurement of elastic modulus of the central bovine cornea by means of holographic interferometry. Part II. Results. Optometry Vision Sci 1994; 71: 27-32.
    • (1994) Optometry Vision Sci , vol.71 , pp. 27-32
    • Forster, W.1    Kasprzak, H.2    von Bally, G.3
  • 20
    • 0030199985 scopus 로고    scopus 로고
    • Regional elastic performance of the human cornea
    • Hjortdal J. Regional elastic performance of the human cornea. J Biomech 1996; 29: 931-942.
    • (1996) J Biomech , vol.29 , pp. 931-942
    • Hjortdal, J.1
  • 21
    • 0030969365 scopus 로고    scopus 로고
    • Relationship between ocular pulse pressures and retinal vessel velocities
    • Michelson G, Harazny J. Relationship between ocular pulse pressures and retinal vessel velocities. Ophthalmology 1997; 104: 664-671.
    • (1997) Ophthalmology , vol.104 , pp. 664-671
    • Michelson, G.1    Harazny, J.2
  • 22
    • 27744472941 scopus 로고    scopus 로고
    • Applications of high speed videokeratoscopy
    • Iskander DR, Collins MJ. Applications of high speed videokeratoscopy. Clin Exp Opt 2005; 88: 223-231.
    • (2005) Clin Exp Opt , vol.88 , pp. 223-231
    • Iskander, D.R.1    Collins, M.J.2
  • 23
    • 34248357799 scopus 로고    scopus 로고
    • Zhu M, Collins MJ, Iskander DR. Dynamics of ocular surface topography. Eye 2006 (advance online publication, April 21; doi:10.1038/ sj.eye.6702293).
    • Zhu M, Collins MJ, Iskander DR. Dynamics of ocular surface topography. Eye 2006 (advance online publication, April 21; doi:10.1038/ sj.eye.6702293).
  • 24
    • 33750125374 scopus 로고    scopus 로고
    • Dynamics in longitudinal eye movements and corneal shape
    • in press
    • Iskander DR, Kasprzak HT. Dynamics in longitudinal eye movements and corneal shape. Ophthal Physiol Opt 2006; (in press).
    • (2006) Ophthal Physiol Opt
    • Iskander, D.R.1    Kasprzak, H.T.2
  • 26
    • 27644520022 scopus 로고    scopus 로고
    • Evaluating tear film stability in the human eye with high speed videokeratoscopy
    • Iskander DR, Collins MJ, Davis B. Evaluating tear film stability in the human eye with high speed videokeratoscopy IEEE Trans Biomed Eng 2005; 52: 1939-1949.
    • (2005) IEEE Trans Biomed Eng , vol.52 , pp. 1939-1949
    • Iskander, D.R.1    Collins, M.J.2    Davis, B.3
  • 27
    • 0035919978 scopus 로고    scopus 로고
    • Use of time frequency analysis to follow transitory modulation of the cardiac autonomic system in clinical studies
    • Baillard C, Gonçalves P, Mangin L, Swynghedauw B, Mansier P. Use of time frequency analysis to follow transitory modulation of the cardiac autonomic system in clinical studies. Auton Neurosci Basic Clin 2001; 90: 24-28.
    • (2001) Auton Neurosci Basic Clin , vol.90 , pp. 24-28
    • Baillard, C.1    Gonçalves, P.2    Mangin, L.3    Swynghedauw, B.4    Mansier, P.5
  • 30
    • 0025463449 scopus 로고
    • The use of cone-shaped kernels for generalized time-frequency representations of nonstationary signals
    • Zhao Y, Atlas LE, Marks RJ. The use of cone-shaped kernels for generalized time-frequency representations of nonstationary signals. IEEE Trans Acoust Speech Signal Process 1990; 38: 1084-1091.
    • (1990) IEEE Trans Acoust Speech Signal Process , vol.38 , pp. 1084-1091
    • Zhao, Y.1    Atlas, L.E.2    Marks, R.J.3
  • 31
    • 0025084562 scopus 로고
    • Arterial pulse modulates steady-state ocular accommodation
    • Winn B, Pugh JR, Gilmartin B, Owens B. Arterial pulse modulates steady-state ocular accommodation. Curr Eye Res 1990; 9: 971-975.
    • (1990) Curr Eye Res , vol.9 , pp. 971-975
    • Winn, B.1    Pugh, J.R.2    Gilmartin, B.3    Owens, B.4
  • 32
    • 0029134658 scopus 로고
    • Microfluctuations of steady-state accommodation and the cardiopulmonary system
    • Collins MJ, Davis B, Wood J. Microfluctuations of steady-state accommodation and the cardiopulmonary system. Vision Res 1995; 35: 2491-2502.
    • (1995) Vision Res , vol.35 , pp. 2491-2502
    • Collins, M.J.1    Davis, B.2    Wood, J.3
  • 33
    • 0034760169 scopus 로고    scopus 로고
    • Consideration of three types of spontaneous eye blink activity in normal humans: During reading and video display terminal use, in primary gaze, and while in conversations
    • Doughty MJ. Consideration of three types of spontaneous eye blink activity in normal humans: During reading and video display terminal use, in primary gaze, and while in conversations. Opt Vision Sci 2001; 78: 712-725.
    • (2001) Opt Vision Sci , vol.78 , pp. 712-725
    • Doughty, M.J.1
  • 34
    • 0042553279 scopus 로고
    • Smoothing and differentiation of data by simplified least squares procedures
    • Savitzky A, Golay MJE. Smoothing and differentiation of data by simplified least squares procedures. Anal Chem 1964; 36: 1627-1639.
    • (1964) Anal Chem , vol.36 , pp. 1627-1639
    • Savitzky, A.1    Golay, M.J.E.2
  • 35
    • 0029095897 scopus 로고
    • The use of coherence functions in the study of ocular mechanism
    • Eadie AS, Pugh JR, Winn B. The use of coherence functions in the study of ocular mechanism. Ophthal Physiol Opt 1995; 15: 311-317.
    • (1995) Ophthal Physiol Opt , vol.15 , pp. 311-317
    • Eadie, A.S.1    Pugh, J.R.2    Winn, B.3
  • 37
    • 0029239598 scopus 로고
    • An advanced signal processing technique for impedance cardiography
    • Wang X, Sun HH, Van De Water JM. An advanced signal processing technique for impedance cardiography. IEEE Trans Biomed Eng 1995; 42: 224-230.
    • (1995) IEEE Trans Biomed Eng , vol.42 , pp. 224-230
    • Wang, X.1    Sun, H.H.2    Van De Water, J.M.3
  • 39
    • 0024836610 scopus 로고
    • Abnormal ocular pneumoplethysmographic results in unilateral neovascular glaucoma
    • Shakin EP, Bosley TM, Gee W, Reed III J, Brown GC, Sergott RC et al. Abnormal ocular pneumoplethysmographic results in unilateral neovascular glaucoma. Arch Neurol 1989; 46: 1308-1310.
    • (1989) Arch Neurol , vol.46 , pp. 1308-1310
    • Shakin, E.P.1    Bosley, T.M.2    Gee, W.3    Reed III, J.4    Brown, G.C.5    Sergott, R.C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.