메뉴 건너뛰기




Volumn 12, Issue 5, 2007, Pages 303-310

Use of a Novel Fluidics Microbead Trap/Flow-Cell Enhances Speed and Sensitivity of Bead-Based Bioassays

Author keywords

bioassay; flow cell; fluidics; microbeads; sequential injection

Indexed keywords

CELLS; ESCHERICHIA COLI; FLOW CYTOMETRY; FLUIDIC DEVICES; MASS TRANSFER; NUCLEIC ACIDS; OLIGONUCLEOTIDES; POLYSTYRENES; PROTEINS; TRACE ANALYSIS;

EID: 34548528971     PISSN: 22110682     EISSN: 15402452     Source Type: Journal    
DOI: 10.1016/j.jala.2007.05.002     Document Type: Article
Times cited : (7)

References (12)
  • 1
    • 0344026334 scopus 로고    scopus 로고
    • Use of magnetic techniques for the isolation of cells
    • Šafařík I. Šafaříková M. Use of magnetic techniques for the isolation of cells. J. Chromatogr. B 1999, 722, 33.
    • (1999) J. Chromatogr. B , vol.722 , pp. 33
    • Šafařík, I.1    Šafaříková, M.2
  • 2
    • 13844256692 scopus 로고    scopus 로고
    • Rapid detection of Escherichia coli 0157:H7 by immunomagnetic separation and real-time PCR
    • Fu Z. Rogelj S. Kieft T. L. Rapid detection of Escherichia coli 0157:H7 by immunomagnetic separation and real-time PCR. Int. J. Food Microbiol. 2005, 99, 47.
    • (2005) Int. J. Food Microbiol. , vol.99 , pp. 47
    • Fu, Z.1    Rogelj, S.2    Kieft, T.L.3
  • 3
    • 28544446736 scopus 로고    scopus 로고
    • Applications of Luminex® xMAP™technology for rapid, high-throughput multiplexed nucleic acid detection
    • Dunbar S. A. Applications of Luminex® xMAP™technology for rapid, high-throughput multiplexed nucleic acid detection. Clin. Chim. Acta. 2006, 363, 71.
    • (2006) Clin. Chim. Acta. , vol.363 , pp. 71
    • Dunbar, S.A.1
  • 4
    • 33644952039 scopus 로고    scopus 로고
    • Solid-phase and bead-based cytokine immunoassay: A comparison
    • de Jager W. Rijkers G. T. Solid-phase and bead-based cytokine immunoassay: A comparison. Methods 2006, 38, 294.
    • (2006) Methods , vol.38 , pp. 294
    • de Jager, W.1    Rijkers, G.T.2
  • 5
    • 11144319404 scopus 로고    scopus 로고
    • Development, validation, and implementation of a multiplex immunoassay for the simultaneous determination of five cytokines in human serum
    • Ray D. A. Bowsher R. R. Smith W. C. Devanarayan V. Willey M. B. Brandt J. T. Dean R. A. Development, validation, and implementation of a multiplex immunoassay for the simultaneous determination of five cytokines in human serum. J. Pharm. Biomed. Anal. 2005, 36, 1037.
    • (2005) J. Pharm. Biomed. Anal. , vol.36 , pp. 1037
    • Ray, D.A.1    Bowsher, R.R.2    Smith, W.C.3    Devanarayan, V.4    Willey, M.B.5    Brandt, J.T.6    Dean, R.A.7
  • 6
    • 0142124329 scopus 로고    scopus 로고
    • Multiplexed microsphere-based flow cytometric immunoassays for human cytokines
    • Kellar K. L. Douglass J. P. Multiplexed microsphere-based flow cytometric immunoassays for human cytokines. J. Immunol. Methods 2003, 279, 277.
    • (2003) J. Immunol. Methods , vol.279 , pp. 277
    • Kellar, K.L.1    Douglass, J.P.2
  • 9
    • 0037439367 scopus 로고    scopus 로고
    • Enhanced nucleic acid capture and flow cytometry detection with peptide nucleic acid probes and tunable-surface microparticles
    • Chandler D. P. Jarrell A. E. Enhanced nucleic acid capture and flow cytometry detection with peptide nucleic acid probes and tunable-surface microparticles. Anal. Biochem. 2003, 312, 182.
    • (2003) Anal. Biochem. , vol.312 , pp. 182
    • Chandler, D.P.1    Jarrell, A.E.2
  • 10
    • 0342424716 scopus 로고    scopus 로고
    • Renewable microcolumns for solid-phase nucleic acid separations and analysis from environmental samples
    • Chandler D. P. Brockman F. J. Holman D. A. Grate J. W. Bruckner-Lea C. J. Renewable microcolumns for solid-phase nucleic acid separations and analysis from environmental samples. Trend. Anal. Chem. 2000, 19(5), 314.
    • (2000) Trend. Anal. Chem. , vol.19 , Issue.5 , pp. 314
    • Chandler, D.P.1    Brockman, F.J.2    Holman, D.A.3    Grate, J.W.4    Bruckner-Lea, C.J.5
  • 11
    • 0037433069 scopus 로고    scopus 로고
    • Automated sample preparation method for suspension arrays using renewable surface separations with multiplexed flow cytometry fluorescence detection
    • Grate J. W. Bruckner-Lea C. J. Jarrell A. E. Chandler D. P. Automated sample preparation method for suspension arrays using renewable surface separations with multiplexed flow cytometry fluorescence detection. Anal. Chim. Acta. 2003, 478(1), 85.
    • (2003) Anal. Chim. Acta. , vol.478 , Issue.1 , pp. 85
    • Grate, J.W.1    Bruckner-Lea, C.J.2    Jarrell, A.E.3    Chandler, D.P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.