Volumn 23, Issue 18, 2007, Pages 9125-9127

A commercially available perfectly hydrophobic material (θA/θR = 180°/180°)

Author keywords

[No Author keywords available]

Indexed keywords

CONTACT ANGLE; HYDROPHOBICITY; NUCLEAR MAGNETIC RESONANCE; SCANNING ELECTRON MICROSCOPY; X RAY PHOTOELECTRON SPECTROSCOPY;

EID: 34548526748     PISSN: 07437463     EISSN: None     Source Type: Journal    
DOI: 10.1021/la701097k     Document Type: Article
Times cited : (76)

References (14)
  • 4
    • 34548535525 scopus 로고    scopus 로고
    • Contact angle measurements were made with a Ramè-Hart telescopic goniometer equipped with a Gilmont syringe and a 24 gauge flat-tipped needle
    • Contact angle measurements were made with a Ramè-Hart telescopic goniometer equipped with a Gilmont syringe and a 24 gauge flat-tipped needle.
  • 5
    • 34548527872 scopus 로고    scopus 로고
    • 19F frequency of 282.38 MHz. The sample spinning speed was 9 kHz. Two recycle delays (2 and 10 s) were used to confirm that quantitative integration could be made.
    • 19F frequency of 282.38 MHz. The sample spinning speed was 9 kHz. Two recycle delays (2 and 10 s) were used to confirm that quantitative integration could be made.
  • 7
    • 34548528636 scopus 로고    scopus 로고
    • XPS spectra were recorded using a Physical Electronics Quantum 2000 spectrometer with a 200 μm spot size, monochromatic Al Kα excitation (50 W), and a takeoff angle of 75°.
    • XPS spectra were recorded using a Physical Electronics Quantum 2000 spectrometer with a 200 μm spot size, monochromatic Al Kα excitation (50 W), and a takeoff angle of 75°.
  • 8
    • 34548525596 scopus 로고    scopus 로고
    • Scanning electron micrographs were obtained using gold-coated samples and a JEOL 6320A field emission scanning electron microscope.
    • Scanning electron micrographs were obtained using gold-coated samples and a JEOL 6320A field emission scanning electron microscope.
  • 11
    • 34548525965 scopus 로고    scopus 로고
    • 13 with UV/ozone through a mask containing an ∼1 mm diameter hole.
    • 13 with UV/ozone through a mask containing an ∼1 mm diameter hole.
  • 12
    • 34548537610 scopus 로고    scopus 로고
    • 1,3-Dimethylimidazolium methyl sulfate and 1 -ethyl-3-methylimidazolium tetrafluoroborate were purchased from Sigma-Aldrich; bis(hydroxyethyl) dimethylammonium methane sulfonate and 1 -ethyl-3-methylimidazolium ethylsulfate were gifts from Degussa. We recently reported the use of ionic liquids as probe fluids for contact angle analysis.14
    • 14