메뉴 건너뛰기




Volumn 85, Issue 1, 2007, Pages 32-40

Finite element-based probabilistic analysis tool for orthopaedic applications

Author keywords

Finite element modeling; Orthopaedic implants; Probabilistic modeling; Reliability; Sensitivity; Variability

Indexed keywords

COMPUTATION THEORY; FINITE ELEMENT METHOD; IMPLANTS (SURGICAL); MATHEMATICAL MODELS; RELIABILITY THEORY;

EID: 34548510074     PISSN: 01692607     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cmpb.2006.09.013     Document Type: Article
Times cited : (85)

References (35)
  • 1
    • 0026993874 scopus 로고
    • Probabilistic damage tolerant analysis for fatigue critical aircraft components
    • Kurth R.E., and Woods K.S. Probabilistic damage tolerant analysis for fatigue critical aircraft components. ASME Aerospace Div. 28 (1992) 89-97
    • (1992) ASME Aerospace Div. , vol.28 , pp. 89-97
    • Kurth, R.E.1    Woods, K.S.2
  • 2
    • 0032660969 scopus 로고    scopus 로고
    • Probabilistic analysis of aircraft gas turbine disk life and reliability
    • Melis M.E., Zaretsky E.V., and August R. Probabilistic analysis of aircraft gas turbine disk life and reliability. J. Propul. Power 15 5 (1999) 658-666
    • (1999) J. Propul. Power , vol.15 , Issue.5 , pp. 658-666
    • Melis, M.E.1    Zaretsky, E.V.2    August, R.3
  • 4
    • 0033167967 scopus 로고    scopus 로고
    • Reliability theory for load bearing biomedical implants
    • Browne M., Langley R.S., and Gregson P.J. Reliability theory for load bearing biomedical implants. Biomaterials 20 (1999) 1285-1292
    • (1999) Biomaterials , vol.20 , pp. 1285-1292
    • Browne, M.1    Langley, R.S.2    Gregson, P.J.3
  • 5
    • 0036348012 scopus 로고    scopus 로고
    • Statistical methods in finite element analysis
    • Dar F.H., Meakin J.R., and Aspden R.M. Statistical methods in finite element analysis. J. Biomech. 35 9 (2002) 1155-1161
    • (2002) J. Biomech. , vol.35 , Issue.9 , pp. 1155-1161
    • Dar, F.H.1    Meakin, J.R.2    Aspden, R.M.3
  • 6
    • 1842635577 scopus 로고    scopus 로고
    • Probabilistic design analysis of the influence of material property on the human cervical spine
    • Ng H.W., and Teo E.C. Probabilistic design analysis of the influence of material property on the human cervical spine. J. Spinal Disord. Tech. 17 2 (2004) 123-133
    • (2004) J. Spinal Disord. Tech. , vol.17 , Issue.2 , pp. 123-133
    • Ng, H.W.1    Teo, E.C.2
  • 8
    • 33646051267 scopus 로고    scopus 로고
    • The effect of three-dimensional shape optimization on the probabilistic response of a cemented femoral hip prosthesis
    • Nicolella D.P., Thacker B.H., Katoozian H., and Davy D.T. The effect of three-dimensional shape optimization on the probabilistic response of a cemented femoral hip prosthesis. J. Biomech. 39 7 (2006) 1265-1278
    • (2006) J. Biomech. , vol.39 , Issue.7 , pp. 1265-1278
    • Nicolella, D.P.1    Thacker, B.H.2    Katoozian, H.3    Davy, D.T.4
  • 16
    • 0025488619 scopus 로고
    • An advanced probabilistic structural analysis method for implicit performance functions
    • Wu Y.T., Millwater H., and Cruse T. An advanced probabilistic structural analysis method for implicit performance functions. AIAA J. 28 9 (1990) 1663-1669
    • (1990) AIAA J. , vol.28 , Issue.9 , pp. 1663-1669
    • Wu, Y.T.1    Millwater, H.2    Cruse, T.3
  • 17
    • 37949011853 scopus 로고    scopus 로고
    • ASTM Standard F 1440-92, Cyclic fatigue testing of metallic stemmed hip arthroplasty femoral components without torsion, Annual Book of ASTM Standards 13.01, ASTM International, West Conshohocken, PA, 2001.
  • 18
    • 37949053089 scopus 로고    scopus 로고
    • ISO 7206-3, Determination of endurance properties of stemmed femoral components without application of torsion, International Organization for Standardization, New York, NY, 1988.
  • 19
    • 0020841489 scopus 로고
    • Ten years of experience with test criteria for fracture-proof anchorage of stems of artificial hip joints
    • Semlitsch M., and Panic B. Ten years of experience with test criteria for fracture-proof anchorage of stems of artificial hip joints. Eng. Med. 12 4 (1983) 185-198
    • (1983) Eng. Med. , vol.12 , Issue.4 , pp. 185-198
    • Semlitsch, M.1    Panic, B.2
  • 21
    • 0022791255 scopus 로고
    • Metallurgical analysis of five failed cast cobalt-chromium-molybdenum alloy hip prostheses
    • Cook S.D., Kester M.A., Harding A.F., Brown T.D., and Sandborn P.M. Metallurgical analysis of five failed cast cobalt-chromium-molybdenum alloy hip prostheses. J. Rehabil. Res. Dev. 23 4 (1986) 27-36
    • (1986) J. Rehabil. Res. Dev. , vol.23 , Issue.4 , pp. 27-36
    • Cook, S.D.1    Kester, M.A.2    Harding, A.F.3    Brown, T.D.4    Sandborn, P.M.5
  • 22
    • 37949048656 scopus 로고    scopus 로고
    • ASTM Standard F 75-98, Cobalt-28 chromium-6 molybdenum casting alloy and cast product for surgical implants, Annual Book of ASTM Standards 13.01, ASTM International, West Conshohocken, PA, 2001.
  • 23
    • 0003855525 scopus 로고    scopus 로고
    • Davis J.R. (Ed), ASM International, Materials Park, OH
    • In: Davis J.R. (Ed). Metals Handbook, Desk Edition. 2nd ed. (1998), ASM International, Materials Park, OH
    • (1998) Metals Handbook, Desk Edition. 2nd ed.
  • 25
    • 0033378144 scopus 로고    scopus 로고
    • Fatigue strength testing of hip stems with statistical analysis
    • Ploeg H., Wevers H.W., Wyss U.P., and Burgi M. Fatigue strength testing of hip stems with statistical analysis. Bio-Med. Mater. Eng. 9 (1999) 243-263
    • (1999) Bio-Med. Mater. Eng. , vol.9 , pp. 243-263
    • Ploeg, H.1    Wevers, H.W.2    Wyss, U.P.3    Burgi, M.4
  • 26
    • 0020700015 scopus 로고
    • Fatigue properties of implant materials in hip prosthesis form: a standardized test
    • Ducheyne P., Wevers M., and De Meester P. Fatigue properties of implant materials in hip prosthesis form: a standardized test. J. Biomed. Mater. Res. 17 (1983) 45-57
    • (1983) J. Biomed. Mater. Res. , vol.17 , pp. 45-57
    • Ducheyne, P.1    Wevers, M.2    De Meester, P.3
  • 28
    • 0034308356 scopus 로고    scopus 로고
    • The use of a force-controlled dynamic knee simulator to quantify the mechanical performance of total knee replacement designs during functional activity
    • DesJardins J.D., Walker P.S., Haider H., and Perry J. The use of a force-controlled dynamic knee simulator to quantify the mechanical performance of total knee replacement designs during functional activity. J. Biomech. 33 (2000) 1231-1242
    • (2000) J. Biomech. , vol.33 , pp. 1231-1242
    • DesJardins, J.D.1    Walker, P.S.2    Haider, H.3    Perry, J.4
  • 29
    • 10444255467 scopus 로고    scopus 로고
    • Explicit finite element modeling of total knee replacement mechanics
    • Halloran J.P., Petrella A.J., and Rullkoetter P.J. Explicit finite element modeling of total knee replacement mechanics. J. Biomech. 38 (2005) 323-331
    • (2005) J. Biomech. , vol.38 , pp. 323-331
    • Halloran, J.P.1    Petrella, A.J.2    Rullkoetter, P.J.3
  • 30
    • 25444453812 scopus 로고    scopus 로고
    • Finite element analysis of knee replacement mechanics during simulated gait using elastic foundation and deformable representations
    • Halloran J.P., Easley S.K., Petrella A.J., and Rullkoetter P.J. Finite element analysis of knee replacement mechanics during simulated gait using elastic foundation and deformable representations. J. Biomech. Eng. 127 (2005) 813-818
    • (2005) J. Biomech. Eng. , vol.127 , pp. 813-818
    • Halloran, J.P.1    Easley, S.K.2    Petrella, A.J.3    Rullkoetter, P.J.4
  • 31
    • 37949057225 scopus 로고    scopus 로고
    • ISO 14243-3, Loading and displacement parameters for wear-testing machines with displacement control and corresponding environmental conditions for test, International Organization for Standardization, New York, NY, 2004.
  • 32
    • 0026131325 scopus 로고
    • Influence of material properties on the mechanical behaviour of the L5-S1 intervertebral disc in compression: a nonlinear finite element study
    • Rao A.A., and Dumas G.A. Influence of material properties on the mechanical behaviour of the L5-S1 intervertebral disc in compression: a nonlinear finite element study. J. Biomed. Eng. 13 2 (1991) 139-151
    • (1991) J. Biomed. Eng. , vol.13 , Issue.2 , pp. 139-151
    • Rao, A.A.1    Dumas, G.A.2
  • 33
    • 0036368219 scopus 로고    scopus 로고
    • Patient-specific spine models. Part 1. Finite element analysis of the lumbar intervertebral disc-a material sensitivity study
    • Fagan M.J., Julian S., Siddall D.J., and Mohsen A.M. Patient-specific spine models. Part 1. Finite element analysis of the lumbar intervertebral disc-a material sensitivity study. Proc. Inst. Mech. Eng. [H] 216 5 (2002) 299-314
    • (2002) Proc. Inst. Mech. Eng. [H] , vol.216 , Issue.5 , pp. 299-314
    • Fagan, M.J.1    Julian, S.2    Siddall, D.J.3    Mohsen, A.M.4
  • 34
    • 0037212118 scopus 로고    scopus 로고
    • How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint
    • Haut Donahue T.L., Hull M.L., Rashid M.M., and Jacobs C.R. How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint. J. Biomech. 36 (2003) 19-34
    • (2003) J. Biomech. , vol.36 , pp. 19-34
    • Haut Donahue, T.L.1    Hull, M.L.2    Rashid, M.M.3    Jacobs, C.R.4
  • 35
    • 2942598190 scopus 로고    scopus 로고
    • The sensitivity of tibiofemoral contact pressure to the size and shape of the lateral and medial menisci
    • Haut Donahue T.L., Hull M.L., Rashid M.M., and Jacobs C.R. The sensitivity of tibiofemoral contact pressure to the size and shape of the lateral and medial menisci. J. Orthopaed. Res. 22 (2004) 807-814
    • (2004) J. Orthopaed. Res. , vol.22 , pp. 807-814
    • Haut Donahue, T.L.1    Hull, M.L.2    Rashid, M.M.3    Jacobs, C.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.