Volumn 304, Issue 1-2, 2007, Pages 181-189

Observation of flow characteristics in a hollow fiber lumen using non-invasive X-ray microimaging (XMI)

Author keywords

Bubbles; Hollow fiber membrane; Lumen flow; Non invasive observation; X ray microimaging

Indexed keywords

CAVITATION; CONTACT ANGLE; FILTRATION; PRESSURE REGULATION; TWO PHASE FLOW;

EID: 34548481086     PISSN: 03767388     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.memsci.2007.07.037     Document Type: Article
Times cited : (20)

References (19)
  • 1
    • 0035882786 scopus 로고    scopus 로고
    • The effect of cake and fiber properties on flux declines in hollow-fiber microfiltration membranes
    • Carroll T. The effect of cake and fiber properties on flux declines in hollow-fiber microfiltration membranes. J. Membr. Sci. 189 (2001) 167-178
    • (2001) J. Membr. Sci. , vol.189 , pp. 167-178
    • Carroll, T.1
  • 2
    • 0032496911 scopus 로고    scopus 로고
    • Dead-end ultrafiltration in hollow fiber modules: module design and process simulation
    • Serra C., Clifton M.J., Moulin P., and Rouch J.-C. Dead-end ultrafiltration in hollow fiber modules: module design and process simulation. J. Membr. Sci. 145 (1998) 159-172
    • (1998) J. Membr. Sci. , vol.145 , pp. 159-172
    • Serra, C.1    Clifton, M.J.2    Moulin, P.3    Rouch, J.-C.4
  • 3
    • 29244443372 scopus 로고    scopus 로고
    • Analysis of constant permeate flow filtration using dead-end hollow fiber membranes
    • Chang S., Fane A.G., and Waite T.D. Analysis of constant permeate flow filtration using dead-end hollow fiber membranes. J. Membr. Sci. 268 2 (2006) 132-141
    • (2006) J. Membr. Sci. , vol.268 , Issue.2 , pp. 132-141
    • Chang, S.1    Fane, A.G.2    Waite, T.D.3
  • 4
    • 0036727168 scopus 로고    scopus 로고
    • Filtration of biomass with laboratory-scale submerged hollow fibre modules-effect of operating conditions and module configuration
    • Chang S., and Fane A.G. Filtration of biomass with laboratory-scale submerged hollow fibre modules-effect of operating conditions and module configuration. J. Chem. Biotechnol. 77 (2002) 1030-1038
    • (2002) J. Chem. Biotechnol. , vol.77 , pp. 1030-1038
    • Chang, S.1    Fane, A.G.2
  • 5
    • 30944458582 scopus 로고    scopus 로고
    • Fibre movement induced by bubbling using submerged hollow fibres
    • Wicaksana F., Fane A.G., and Chen V. Fibre movement induced by bubbling using submerged hollow fibres. J. Membr. Sci. 271 1-2 (2006) 186-195
    • (2006) J. Membr. Sci. , vol.271 , Issue.1-2 , pp. 186-195
    • Wicaksana, F.1    Fane, A.G.2    Chen, V.3
  • 6
    • 14644400449 scopus 로고    scopus 로고
    • Non-invasive observation of external and internal deposition during membrane filtration by X-ray microimaging (XMI)
    • Yeo A., Yang P., Fane A.G., White T., and Moser H. Non-invasive observation of external and internal deposition during membrane filtration by X-ray microimaging (XMI). J. Membr. Sci. 250 (2005) 189-193
    • (2005) J. Membr. Sci. , vol.250 , pp. 189-193
    • Yeo, A.1    Yang, P.2    Fane, A.G.3    White, T.4    Moser, H.5
  • 7
    • 0025217464 scopus 로고
    • Quantitative flow measurement in bioreactors by NRM imaging
    • Hammer B.E., Heath C.A., Mire S.D., and Belfort G. Quantitative flow measurement in bioreactors by NRM imaging. Biotechnology 8 (1990) 327-330
    • (1990) Biotechnology , vol.8 , pp. 327-330
    • Hammer, B.E.1    Heath, C.A.2    Mire, S.D.3    Belfort, G.4
  • 8
    • 0034234651 scopus 로고    scopus 로고
    • Characteristics of microfiltration of suspensions with inter-fiber two-phase flow
    • Chang S., and Fane A.G. Characteristics of microfiltration of suspensions with inter-fiber two-phase flow. J. Chem. Technol. Biotechnol. 75 (2000) 533-540
    • (2000) J. Chem. Technol. Biotechnol. , vol.75 , pp. 533-540
    • Chang, S.1    Fane, A.G.2
  • 9
    • 0029055322 scopus 로고
    • Non-invasive observation of flow profiles and polarization layers in hollow fiber membrane filtration modules using NMR micro-imaging
    • Yao S., Costello M., Fane A.G., and Pope J.M. Non-invasive observation of flow profiles and polarization layers in hollow fiber membrane filtration modules using NMR micro-imaging. J. Membr. Sci. 99 (1995) 207-216
    • (1995) J. Membr. Sci. , vol.99 , pp. 207-216
    • Yao, S.1    Costello, M.2    Fane, A.G.3    Pope, J.M.4
  • 10
    • 0042164483 scopus 로고    scopus 로고
    • The use of gas bubbling to enhance membrane processes
    • (Review)
    • Cui Z.F., Chang S., and Fane A.G. The use of gas bubbling to enhance membrane processes. J. Membr. Sci. 221 (2003) 1-35 (Review)
    • (2003) J. Membr. Sci. , vol.221 , pp. 1-35
    • Cui, Z.F.1    Chang, S.2    Fane, A.G.3
  • 11
    • 0345687930 scopus 로고    scopus 로고
    • Critical flux determination by the flux-step method in a submerged membrane bioreactor
    • Le-Clech P., Jefferson B., Chang I.S., and Judd S.J. Critical flux determination by the flux-step method in a submerged membrane bioreactor. J. Membr. Sci. 227 (2003) 81-93
    • (2003) J. Membr. Sci. , vol.227 , pp. 81-93
    • Le-Clech, P.1    Jefferson, B.2    Chang, I.S.3    Judd, S.J.4
  • 12
    • 0036824291 scopus 로고    scopus 로고
    • Modeling and optimizing submerged hollow fiber membrane modules
    • Chang S., Fane A.G., and Vigneswaran S. Modeling and optimizing submerged hollow fiber membrane modules. AIChE. J. 48 10 (2002) 2203-2212
    • (2002) AIChE. J. , vol.48 , Issue.10 , pp. 2203-2212
    • Chang, S.1    Fane, A.G.2    Vigneswaran, S.3
  • 13
    • 21244505853 scopus 로고    scopus 로고
    • Performance of individual fiber in a submerged hollow fiber bundles
    • Yeo A., and Fane A.G. Performance of individual fiber in a submerged hollow fiber bundles. Water Sci. Technol. 51 6-7 (2005) 165-172
    • (2005) Water Sci. Technol. , vol.51 , Issue.6-7 , pp. 165-172
    • Yeo, A.1    Fane, A.G.2
  • 14
    • 0035970912 scopus 로고    scopus 로고
    • The effect of fibre diameter on filtration and flux distribution-relevance to submerged hollow fibre modules
    • Chang S., and Fane A.G. The effect of fibre diameter on filtration and flux distribution-relevance to submerged hollow fibre modules. J. Membr. Sci. 184 2 (2001) 221-231
    • (2001) J. Membr. Sci. , vol.184 , Issue.2 , pp. 221-231
    • Chang, S.1    Fane, A.G.2
  • 15
    • 0037188307 scopus 로고    scopus 로고
    • Experimental assessment of filtration of biomass with transverse and axial fibers
    • Chang S., Fane A.G., and Vigneswaran S. Experimental assessment of filtration of biomass with transverse and axial fibers. Chem. Eng. J. 87 1 (2002) 121-127
    • (2002) Chem. Eng. J. , vol.87 , Issue.1 , pp. 121-127
    • Chang, S.1    Fane, A.G.2    Vigneswaran, S.3
  • 16
    • 27644593498 scopus 로고    scopus 로고
    • Mechanical analysis of hollow fiber membrane integrity in water reuse application
    • Childress A.E., Le-Clech P., Daugherty J.L., Chen C., and Leslie G.L. Mechanical analysis of hollow fiber membrane integrity in water reuse application. Desalination 180 1-3 (2005) 5-14
    • (2005) Desalination , vol.180 , Issue.1-3 , pp. 5-14
    • Childress, A.E.1    Le-Clech, P.2    Daugherty, J.L.3    Chen, C.4    Leslie, G.L.5
  • 17
    • 34548490427 scopus 로고    scopus 로고
    • S. Chang, A.G. Fane, T.D. Waite, A. Yeo, Unstable filtration behavior with submerged hollow fiber membrane, J. Membr. Sci., submitted for publication.
  • 18
    • 0000402361 scopus 로고
    • The crevice model of bubble nucleation
    • Atchley A.A., and Prosperetti A. The crevice model of bubble nucleation. J. Acoust. Soc. Am. 86 3 (1989) 1065-1084
    • (1989) J. Acoust. Soc. Am. , vol.86 , Issue.3 , pp. 1065-1084
    • Atchley, A.A.1    Prosperetti, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.