메뉴 건너뛰기




Volumn 21, Issue 9, 2007, Pages 1508-1511

Evaluation of the mechanical strength and patency of functional end-to-end anastomoses

Author keywords

Bursting pressure; Functional end to end anastomosis; Patency

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL TISSUE; ARTICLE; CONTROLLED STUDY; END TO END ANASTOMOSIS; INTESTINE; NONHUMAN; PRIORITY JOURNAL; STAPLER; STATISTICAL SIGNIFICANCE; SWINE;

EID: 34548431732     PISSN: 09302794     EISSN: 14322218     Source Type: Journal    
DOI: 10.1007/s00464-006-9131-6     Document Type: Article
Times cited : (28)

References (16)
  • 1
    • 14644423266 scopus 로고    scopus 로고
    • A comparison of burst pressure between buttressed versus nonbuttressed staple-lines in an animal model
    • Arnold W, Shikora SA (2005) A comparison of burst pressure between buttressed versus nonbuttressed staple-lines in an animal model. Obes Surg 15: 164-171
    • (2005) Obes Surg , vol.15 , pp. 164-171
    • Arnold, W.1    Shikora, S.A.2
  • 5
    • 0025851051 scopus 로고
    • Anastomotic obstruction after stapled enteroanastomosis
    • Ostericher R, Lally KP, Barrett DM, Richey ML (1991) Anastomotic obstruction after stapled enteroanastomosis. Surgery 109: 799-801
    • (1991) Surgery , vol.109 , pp. 799-801
    • Ostericher, R.1    Lally, K.P.2    Barrett, D.M.3    Richey, M.L.4
  • 7
    • 0018755782 scopus 로고
    • A stapling instrument for end to end inverting anastomosis in the gastrointestinal tract
    • Ravitch MM, Steichen FM (1979) A stapling instrument for end to end inverting anastomosis in the gastrointestinal tract. Ann Surg 189: 791-797
    • (1979) Ann Surg , vol.189 , pp. 791-797
    • Ravitch, M.M.1    Steichen, F.M.2
  • 8
    • 0027442310 scopus 로고
    • Comparison of different techniques of stapled bowel anastomoses in a canine model
    • Ritchey ML, Lally KP, Ostericher R (1993) Comparison of different techniques of stapled bowel anastomoses in a canine model. Arch Surg 128:1365-1367
    • (1993) Arch Surg , vol.128 , pp. 1365-1367
    • Ritchey, M.L.1    Lally, K.P.2    Ostericher, R.3
  • 9
    • 0034005329 scopus 로고    scopus 로고
    • "dog ear" formation after double-stapled low anterior resection as a risk factor for anastomotic disruption
    • Roumen RMH, Rahusen FTG, Wijnen MHWA, Croiset van Uchelen GAAM (2000) "Dog ear" formation after double-stapled low anterior resection as a risk factor for anastomotic disruption. Dis Colon Rectum 43: 522-525
    • (2000) Dis Colon Rectum , vol.43 , pp. 522-525
    • Roumen, R.M.H.1    Rahusen, F.T.G.2    Mhwa, W.3    Croiset Uchelen Gaam, V.4
  • 10
    • 0031886633 scopus 로고    scopus 로고
    • Risk factors for anastomotic leakage after resection of rectal cancer
    • Rullier E, Laurent C, Garrelon JL, Michel P (1998) Risk factors for anastomotic leakage after resection of rectal cancer. Br J Surg 85: 355-358
    • (1998) Br J Surg , vol.85 , pp. 355-358
    • Rullier, E.1    Laurent, C.2    Garrelon, J.L.3    Michel, P.4
  • 11
    • 0032863466 scopus 로고    scopus 로고
    • Which technique, circular stapled anastomosis or double stapling anastomosis, provides the optimal size and shape of rectal anastomotic opening?
    • Sadahiro S, Kameya T, Iwase H, Ishhikawa K, Suzuki T, Tokunaga N, Tajima T, Makuuchi H (1999) Which technique, circular stapled anastomosis or double stapling anastomosis, provides the optimal size and shape of rectal anastomotic opening? J Surg Res 86: 162-166
    • (1999) J Surg Res , vol.86 , pp. 162-166
    • Sadahiro, S.1    Kameya, T.2    Iwase, H.3    Ishhikawa, K.4    Suzuki, T.5    Tokunaga, N.6    Tajima, T.7    Makuuchi, H.8
  • 13
    • 0036168285 scopus 로고    scopus 로고
    • Early bursting strength of human colon anastomoses: An in vitro study comparing current anastomotic techniques
    • Schwab R, Weşendorf S, Gutcke A, Becker HP (2002) Early bursting strength of human colon anastomoses: an in vitro study comparing current anastomotic techniques. Langenbeck Arch Surg 386: 507-511
    • (2002) Langenbeck Arch Surg , vol.386 , pp. 507-511
    • Schwab, R.1    Weşendorf, S.2    Gutcke, A.3    Becker, H.P.4
  • 14
    • 0014360507 scopus 로고
    • The use of staplers in anatomical side-to-side and functional end-to-end enteroanastomoses
    • Steichen FM (1968) The use of staplers in anatomical side-to-side and functional end-to-end enteroanastomoses. Surgery 64: 948-953
    • (1968) Surgery , vol.64 , pp. 948-953
    • Steichen, F.M.1
  • 15
    • 0015598522 scopus 로고
    • Mechanical sutures in surgery
    • Steichen FM, Ravitch MM (1973) Mechanical sutures in surgery. Br J Surg 60: 191-197
    • (1973) Br J Surg , vol.60 , pp. 191-197
    • Steichen, F.M.1    Ravitch, M.M.2
  • 16
    • 0033825385 scopus 로고    scopus 로고
    • Laparoscopic gastric bypass, Roux-en-Y-500 patients: Technique and results with 3-60 month follow-up
    • Wittgrove AC, Clark GW (2000) Laparoscopic gastric bypass, Roux-en-Y-500 patients: technique and results with 3-60 month follow-up. Obes Surg 10: 233-239
    • (2000) Obes Surg , vol.10 , pp. 233-239
    • Wittgrove, A.C.1    Clark, G.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.