메뉴 건너뛰기




Volumn 32, Issue 4, 2007, Pages 604-610

A three-dimensional echocardiographic comparison of a deep pericardial stitch versus an apical suction device for heart positioning during beating heart surgery

Author keywords

Apical suction device; Beating heart surgery; Deep pericardial stitch; Three dimensional echo

Indexed keywords

ADULT; ANALYSIS OF VARIANCE; APICAL SUCTION DEVICE; APPARATUS; ARTICLE; CALCULATION; CENTRAL VENOUS PRESSURE; CLINICAL ARTICLE; COMPUTER PROGRAM; DEEP PERICARDIAL STITCH; FEMALE; GEOMETRY; HEART DISEASE; HEART EJECTION FRACTION; HEART LEFT ATRIUM PRESSURE; HEART LEFT VENTRICLE FUNCTION; HEART STROKE VOLUME; HEART VENTRICLE VOLUME; HEMODYNAMICS; HUMAN; IMAGE RECONSTRUCTION; INTERMETHOD COMPARISON; LUNG ARTERY PRESSURE; MALE; MEASUREMENT; MITRAL VALVE; OFF PUMP SURGERY; PERICARDIUM; PRIORITY JOURNAL; ROTATION; SUCTION; SURGICAL TECHNIQUE; SUTURING METHOD; THREE DIMENSIONAL ECHOCARDIOGRAPHY; TRANSESOPHAGEAL ECHOCARDIOGRAPHY;

EID: 34548424055     PISSN: 10107940     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejcts.2007.07.009     Document Type: Article
Times cited : (5)

References (18)
  • 1
    • 0032717765 scopus 로고    scopus 로고
    • Single suture for circumflex exposure in off-pump coronary artery bypass grafting
    • Bergsland J., Karamanoukian H.L., Soltoski P.R., and Salerno T.A. Single suture for circumflex exposure in off-pump coronary artery bypass grafting. Ann Thorac Surg 68 (1999) 1428-1430
    • (1999) Ann Thorac Surg , vol.68 , pp. 1428-1430
    • Bergsland, J.1    Karamanoukian, H.L.2    Soltoski, P.R.3    Salerno, T.A.4
  • 4
    • 9344257286 scopus 로고    scopus 로고
    • Hemodynamic changes during posterior vessel off-pump coronary artery bypass: comparison between deep pericardial sutures and vacuum-assisted apical suction device
    • Chang W.I., Kim K.B., Kim J.H., Ham B.M., and Kim Y.L. Hemodynamic changes during posterior vessel off-pump coronary artery bypass: comparison between deep pericardial sutures and vacuum-assisted apical suction device. Ann Thorac Surg 78 (2004) 2057-2062
    • (2004) Ann Thorac Surg , vol.78 , pp. 2057-2062
    • Chang, W.I.1    Kim, K.B.2    Kim, J.H.3    Ham, B.M.4    Kim, Y.L.5
  • 5
    • 0036266220 scopus 로고    scopus 로고
    • Mitral annulus distortion during beating heart surgery: a potential cause for hemodynamic disturbance - a three-dimensional echocardiography reconstruction study
    • George S.J., Al Ruzzeh S., and Amrani M. Mitral annulus distortion during beating heart surgery: a potential cause for hemodynamic disturbance - a three-dimensional echocardiography reconstruction study. Ann Thorac Surg 73 (2002) 1424-1430
    • (2002) Ann Thorac Surg , vol.73 , pp. 1424-1430
    • George, S.J.1    Al Ruzzeh, S.2    Amrani, M.3
  • 6
    • 2442625806 scopus 로고    scopus 로고
    • Evaluation of serial haemodynamic changes during coronary artery anastomoses in patients undergoing off-pump coronary artery bypass graft surgery: initial experiences using two deep pericardial stay sutures and octopus tissue stabilizer
    • Shinn H.K., Oh Y.J., Kim S.H., Lee J.H., Lee C.S., and Kwak Y.L. Evaluation of serial haemodynamic changes during coronary artery anastomoses in patients undergoing off-pump coronary artery bypass graft surgery: initial experiences using two deep pericardial stay sutures and octopus tissue stabilizer. Eur J Cardiothorac Surg 25 (2004) 978-984
    • (2004) Eur J Cardiothorac Surg , vol.25 , pp. 978-984
    • Shinn, H.K.1    Oh, Y.J.2    Kim, S.H.3    Lee, J.H.4    Lee, C.S.5    Kwak, Y.L.6
  • 7
    • 0036674560 scopus 로고    scopus 로고
    • Multi-vessel off-pump coronary aortic bypass grafting with an impaired and severely dilated left ventricle using the starfish heart positioner
    • Niinami H., Takeuchi Y., Ichikawa S., Ban T., Higashita R., Suda Y., and Yamamoto M. Multi-vessel off-pump coronary aortic bypass grafting with an impaired and severely dilated left ventricle using the starfish heart positioner. Kyobu Geka 55 (2002) 773-777
    • (2002) Kyobu Geka , vol.55 , pp. 773-777
    • Niinami, H.1    Takeuchi, Y.2    Ichikawa, S.3    Ban, T.4    Higashita, R.5    Suda, Y.6    Yamamoto, M.7
  • 8
    • 0027280792 scopus 로고
    • Left ventricular volume and endocardial surface area by three-dimensional echocardiography: comparison with two-dimensional echocardiography and nuclear magnetic resonance imaging in normal subjects
    • Gopal A.S., Keller A.M., Rigling R., King D.L., and King D.L. Left ventricular volume and endocardial surface area by three-dimensional echocardiography: comparison with two-dimensional echocardiography and nuclear magnetic resonance imaging in normal subjects. J Am Coll Cardiol 22 (1993) 258-270
    • (1993) J Am Coll Cardiol , vol.22 , pp. 258-270
    • Gopal, A.S.1    Keller, A.M.2    Rigling, R.3    King, D.L.4    King, D.L.5
  • 9
    • 0029884190 scopus 로고    scopus 로고
    • Evaluation of left ventricular volume and ejection fraction using three dimensional transesophageal echocardiography
    • Yagi T., Yoshida K., Hozumi T., Akasaka T., Takagi T., Honda Y., Ohkura H., Yamamuro A., and Yoshikawa J. Evaluation of left ventricular volume and ejection fraction using three dimensional transesophageal echocardiography. J Cardiol 27 (1996) 207-210
    • (1996) J Cardiol , vol.27 , pp. 207-210
    • Yagi, T.1    Yoshida, K.2    Hozumi, T.3    Akasaka, T.4    Takagi, T.5    Honda, Y.6    Ohkura, H.7    Yamamuro, A.8    Yoshikawa, J.9
  • 10
    • 0030292333 scopus 로고    scopus 로고
    • Three-dimensional echocardiographic measurement of left ventricular volumes and ejection fraction using a multiplane transesophageal probe in patients
    • Hozumi T., Yoshikawa J., Yoshida K., Akasaka T., Takagi T., and Yamamuro A. Three-dimensional echocardiographic measurement of left ventricular volumes and ejection fraction using a multiplane transesophageal probe in patients. Am J Cardiol 78 (1996) 1077-1080
    • (1996) Am J Cardiol , vol.78 , pp. 1077-1080
    • Hozumi, T.1    Yoshikawa, J.2    Yoshida, K.3    Akasaka, T.4    Takagi, T.5    Yamamuro, A.6
  • 11
    • 0035985815 scopus 로고    scopus 로고
    • Three-dimensional echocardiographic measurement of left and right ventricular mass and volume: in vitro validation
    • Hubka M., Bolson E.L., McDonald J.A., Martin R.W., Munt B., and Sheehan F.H. Three-dimensional echocardiographic measurement of left and right ventricular mass and volume: in vitro validation. Int J Cardiovasc Imaging 18 (2002) 111-118
    • (2002) Int J Cardiovasc Imaging , vol.18 , pp. 111-118
    • Hubka, M.1    Bolson, E.L.2    McDonald, J.A.3    Martin, R.W.4    Munt, B.5    Sheehan, F.H.6
  • 13
    • 0029851616 scopus 로고    scopus 로고
    • Three-dimensional echocardiographic reconstruction of the left ventricle by a transesophageal tomographic technique: in vitro and in vivo validation of its volume measurement
    • Pai R.G., Jintapakorn W., Tanimoto M., Cao Q.L., Pandian N., and Shah P.M. Three-dimensional echocardiographic reconstruction of the left ventricle by a transesophageal tomographic technique: in vitro and in vivo validation of its volume measurement. Echocardiography 3 (1996) 613-622
    • (1996) Echocardiography , vol.3 , pp. 613-622
    • Pai, R.G.1    Jintapakorn, W.2    Tanimoto, M.3    Cao, Q.L.4    Pandian, N.5    Shah, P.M.6
  • 14


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.