메뉴 건너뛰기




Volumn 110, Issue 2 II, 2007, Pages 487-490

Alopecia associated with birth injury

Author keywords

[No Author keywords available]

Indexed keywords

ALOPECIA; ARTICLE; BIRTH INJURY; CASE REPORT; CEPHALOMETRY; DISEASE ASSOCIATION; HUMAN; INFANT; NECROSIS; NEWBORN; NEWBORN CARE; OCCIPITAL BONE; PEDIATRIC HOSPITAL; PLASTIC SURGERY; PRESCHOOL CHILD; PRIORITY JOURNAL; SKULL; TERTIARY HEALTH CARE; TISSUE EXPANSION; VACUUM EXTRACTION; ADULT; EDEMA; FEMALE; HAIR; MALE; PREGNANCY; SCALP; TRANSPLANTATION;

EID: 34548395411     PISSN: 00297844     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.AOG.0000259909.77042.ec     Document Type: Article
Times cited : (11)

References (21)
  • 1
    • 0033015719 scopus 로고    scopus 로고
    • Prenatal pressure necrosis of the scalp
    • Matthews M. Prenatal pressure necrosis of the scalp. Ann Plast Surg 1999;43:74-6.
    • (1999) Ann Plast Surg , vol.43 , pp. 74-76
    • Matthews, M.1
  • 2
    • 0015515957 scopus 로고
    • Cicatricial alopecia: A complication of vacuum extraction
    • Aron R, Gordon W. Cicatricial alopecia: a complication of vacuum extraction. S Afr Med J 1972;45:671.
    • (1972) S Afr Med J , vol.45 , pp. 671
    • Aron, R.1    Gordon, W.2
  • 3
    • 25144479034 scopus 로고    scopus 로고
    • Ischaemic gangrene of the scalp in the neonate: A complication of obstructed labour
    • Kulshrestha S, Kulshrestha M, Sarkar B, Chandra M, Singh P, Agarwal N, et al. Ischaemic gangrene of the scalp in the neonate: a complication of obstructed labour. BJOG 2005;112:1334-5.
    • (2005) BJOG , vol.112 , pp. 1334-1335
    • Kulshrestha, S.1    Kulshrestha, M.2    Sarkar, B.3    Chandra, M.4    Singh, P.5    Agarwal, N.6
  • 4
    • 0021465493 scopus 로고
    • Halo scalp ring: A form of localized scalp injury associated with caput succedaneum
    • Neal P, Merk P, Norins A. Halo scalp ring: a form of localized scalp injury associated with caput succedaneum. Pediatr Dermatol 1984;2:52-4.
    • (1984) Pediatr Dermatol , vol.2 , pp. 52-54
    • Neal, P.1    Merk, P.2    Norins, A.3
  • 5
    • 34548681403 scopus 로고
    • A new type of cicatricial alopecia: Alopecia caused by obstetrical vacuum extractor [in French]
    • Vilanova X. A new type of cicatricial alopecia: alopecia caused by obstetrical vacuum extractor [in French]. Bull Soc Fr Dermatol Syphiligr 1961;68:202-3.
    • (1961) Bull Soc Fr Dermatol Syphiligr , vol.68 , pp. 202-203
    • Vilanova, X.1
  • 6
    • 0017249624 scopus 로고
    • Cicatricial alopecia and reduced pigmentation following vacuum extraction [in German]
    • Broese I. Cicatricial alopecia and reduced pigmentation following vacuum extraction [in German]. Dermatol Monatsschr 1976;162:254-7.
    • (1976) Dermatol Monatsschr , vol.162 , pp. 254-257
    • Broese, I.1
  • 7
    • 34548682766 scopus 로고
    • Traumatic cicatricial alopecia in an infant girl. Result of the use of a vacuum extractor (ventouse)
    • Hall-Smith P, Foulkes JF. Traumatic cicatricial alopecia in an infant girl. Result of the use of a vacuum extractor (ventouse). Arch Dermatol 1964;89:473-4.
    • (1964) Arch Dermatol , vol.89 , pp. 473-474
    • Hall-Smith, P.1    Foulkes, J.F.2
  • 8
    • 0019041027 scopus 로고
    • Permanent baldness following caput succedaneum
    • Das S. Permanent baldness following caput succedaneum. J R Coll Gen Pract 1980;30:428-9.
    • (1980) J R Coll Gen Pract , vol.30 , pp. 428-429
    • Das, S.1
  • 9
    • 0022154176 scopus 로고
    • Halo ring scalp associated with caput succedaneum
    • Beutner KR. Halo ring scalp associated with caput succedaneum. Pediatr Dermatol 1985;3:83.
    • (1985) Pediatr Dermatol , vol.3 , pp. 83
    • Beutner, K.R.1
  • 10
    • 0023391455 scopus 로고
    • Halo scalp ring: A cause of scarring alopecia
    • Prendiville JS, Esterly NB. Halo scalp ring: a cause of scarring alopecia. Arch Dermatol 1987;123:992-3.
    • (1987) Arch Dermatol , vol.123 , pp. 992-993
    • Prendiville, J.S.1    Esterly, N.B.2
  • 12
    • 0026093122 scopus 로고
    • Scalp necrosis in a neonate treated with cultured autologous keratinocytes
    • Morykwas MJ, Beason ES, Argenta LC. Scalp necrosis in a neonate treated with cultured autologous keratinocytes. Plast Reconstr Surg 1991;87:549-52.
    • (1991) Plast Reconstr Surg , vol.87 , pp. 549-552
    • Morykwas, M.J.1    Beason, E.S.2    Argenta, L.C.3
  • 13
    • 33744754089 scopus 로고    scopus 로고
    • An incomplete circle of alopecia: A new case of halo scalp ring?
    • Patrizi A, Savoia F, Neri I, Bardazzi F. An incomplete circle of alopecia: a new case of halo scalp ring? Acta Derm Venereol 2006;86:65-6.
    • (2006) Acta Derm Venereol , vol.86 , pp. 65-66
    • Patrizi, A.1    Savoia, F.2    Neri, I.3    Bardazzi, F.4
  • 14
    • 34548701339 scopus 로고
    • Cicatricial alopecia following vacuum extraction of the fetus
    • Byanov B. Cicatricial alopecia following vacuum extraction of the fetus. Derm Vener (Sofia) 1970;9:134.
    • (1970) Derm Vener (Sofia) , vol.9 , pp. 134
    • Byanov, B.1
  • 15
    • 34548664584 scopus 로고
    • Traumatic alopecia following vacuum extraction
    • Glavanakova V, Vulov V. Traumatic alopecia following vacuum extraction. Derm Vener (Sofia) 1965;4:262.
    • (1965) Derm Vener (Sofia) , vol.4 , pp. 262
    • Glavanakova, V.1    Vulov, V.2
  • 16
    • 0344013542 scopus 로고    scopus 로고
    • Instrumental extraction in 2002 in the "AURORE" hospital network: Incidence and serious neonatal complications [in French]
    • Dupuis O, Silveira R, Redarce T, Dittmar A, Rodrigoz RC. Instrumental extraction in 2002 in the "AURORE" hospital network: incidence and serious neonatal complications [in French]. Gynecol Obstet Fertil 2003;31:920-6.
    • (2003) Gynecol Obstet Fertil , vol.31 , pp. 920-926
    • Dupuis, O.1    Silveira, R.2    Redarce, T.3    Dittmar, A.4    Rodrigoz, R.C.5
  • 17
    • 0031080834 scopus 로고    scopus 로고
    • Vacuum extraction: Does duration predict scalp injury?
    • Teng FY, Sayre JW. Vacuum extraction: does duration predict scalp injury? Obstet Gynecol 1997;89:281-5.
    • (1997) Obstet Gynecol , vol.89 , pp. 281-285
    • Teng, F.Y.1    Sayre, J.W.2
  • 18
    • 10044247892 scopus 로고
    • The importance of flexion in vacuum extraction delivery
    • Bird GC. The importance of flexion in vacuum extraction delivery. Br J Obstet Gynaecol 1976;83:194-200.
    • (1976) Br J Obstet Gynaecol , vol.83 , pp. 194-200
    • Bird, G.C.1
  • 19
    • 0027309376 scopus 로고
    • A randomised prospective study comparing the new vacuum extractor policy with forceps delivery
    • Johanson RB, Rice C, Doyle M, Arthur J, Anyanwu L, Ibrahim J, et al. A randomised prospective study comparing the new vacuum extractor policy with forceps delivery. Br J Obstet Gynaecol 1993;100:524-30.
    • (1993) Br J Obstet Gynaecol , vol.100 , pp. 524-530
    • Johanson, R.B.1    Rice, C.2    Doyle, M.3    Arthur, J.4    Anyanwu, L.5    Ibrahim, J.6
  • 20
    • 0020348935 scopus 로고
    • The use of vacuum extractor
    • Bird GC. The use of vacuum extractor. Clin Obstet Gynaecol 1982;9:641-61.
    • (1982) Clin Obstet Gynaecol , vol.9 , pp. 641-661
    • Bird, G.C.1
  • 21
    • 0018345473 scopus 로고
    • Fetal cranial injuries related to delivery with the Malmstrom vacuum extractor
    • Plauche WC. Fetal cranial injuries related to delivery with the Malmstrom vacuum extractor. Obstet Gynecol 1979;53:750-7.
    • (1979) Obstet Gynecol , vol.53 , pp. 750-757
    • Plauche, W.C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.