메뉴 건너뛰기




Volumn 188, Issue 1, 2007, Pages 74-82

Operating nanoliter scale NMR microcoils in a 1 tesla field

Author keywords

Microcoil; Permanent magnet; SNR

Indexed keywords

ELECTRIC INDUCTORS; NUCLEAR MAGNETIC RESONANCE; PERMANENT MAGNETS; PROBES; SIGNAL TO NOISE RATIO; TUNING;

EID: 34548394118     PISSN: 10907807     EISSN: 10960856     Source Type: Journal    
DOI: 10.1016/j.jmr.2007.06.008     Document Type: Article
Times cited : (25)

References (31)
  • 1
    • 0029355413 scopus 로고
    • Design and analysis of microcoils for NMR microscopy
    • Peck T.L., Magin R.L., and Lauterbur P.C. Design and analysis of microcoils for NMR microscopy. J. Magn. Reson. B 108 (1995) 114-124
    • (1995) J. Magn. Reson. , vol.B 108 , pp. 114-124
    • Peck, T.L.1    Magin, R.L.2    Lauterbur, P.C.3
  • 3
    • 0030267495 scopus 로고    scopus 로고
    • Signal-to-noise and magnetic susceptibility trade-offs in solenoidal microcoils for NMR
    • Webb A.G., and Grant S.C. Signal-to-noise and magnetic susceptibility trade-offs in solenoidal microcoils for NMR. J. Magn. Reson. B 113 (1996) 83-87
    • (1996) J. Magn. Reson. , vol.B 113 , pp. 83-87
    • Webb, A.G.1    Grant, S.C.2
  • 4
    • 0031554189 scopus 로고    scopus 로고
    • Using microcontact printing to fabricate microcoils on capillaries for high resolution proton nuclear magnetic resonance on nanoliter volumes
    • Rogers J.A., Jackman R.J., Whitesides G.M., Olson D.L., and Sweedler J.V. Using microcontact printing to fabricate microcoils on capillaries for high resolution proton nuclear magnetic resonance on nanoliter volumes. Appl. Phys. Lett. 70 (1997) 2464-2466
    • (1997) Appl. Phys. Lett. , vol.70 , pp. 2464-2466
    • Rogers, J.A.1    Jackman, R.J.2    Whitesides, G.M.3    Olson, D.L.4    Sweedler, J.V.5
  • 5
    • 0031281736 scopus 로고    scopus 로고
    • Nanoliter volume high-resolution NMR microspectroscopv using a 60-um planer microcoil
    • Stocker J.E., Peck T.L., Webb A.G., Feng M., and Magin R.L. Nanoliter volume high-resolution NMR microspectroscopv using a 60-um planer microcoil. IEEE Trans. Biomed. Eng. 44 (1997) 1122-1127
    • (1997) IEEE Trans. Biomed. Eng. , vol.44 , pp. 1122-1127
    • Stocker, J.E.1    Peck, T.L.2    Webb, A.G.3    Feng, M.4    Magin, R.L.5
  • 6
    • 0032535627 scopus 로고    scopus 로고
    • Limited-sample NMR using solenoidal microcoils, perfluorocarbon plugs, and capillary spinning
    • Behnia B., and Webb A.G. Limited-sample NMR using solenoidal microcoils, perfluorocarbon plugs, and capillary spinning. Anal. Chem. 70 (1998) 5326-5331
    • (1998) Anal. Chem. , vol.70 , pp. 5326-5331
    • Behnia, B.1    Webb, A.G.2
  • 7
    • 0032109981 scopus 로고    scopus 로고
    • RF microcoil design for practical NMR of mass-limited samples
    • Subramanian R., Lam M.M., and Webb A.G. RF microcoil design for practical NMR of mass-limited samples. J. Magn. Reson. 133 (1998) 227-231
    • (1998) J. Magn. Reson. , vol.133 , pp. 227-231
    • Subramanian, R.1    Lam, M.M.2    Webb, A.G.3
  • 8
    • 0031989836 scopus 로고    scopus 로고
    • High-resolution microcoil NMR for analysis of mass-limited, nanoliter samples
    • Olson D.L., Lacey M.E., and Sweedler J.V. High-resolution microcoil NMR for analysis of mass-limited, nanoliter samples. Anal. Chem. 70 (1998) 645-650
    • (1998) Anal. Chem. , vol.70 , pp. 645-650
    • Olson, D.L.1    Lacey, M.E.2    Sweedler, J.V.3
  • 9
    • 0345742521 scopus 로고    scopus 로고
    • Laser-lathe lithography-a novel method for manufacturing nuclear magnetic resonance microcoils
    • Malba V., Maxwell R., Evans L.B., Bernhardt A.F., Cosman M., and Yan K. Laser-lathe lithography-a novel method for manufacturing nuclear magnetic resonance microcoils. Biomed. Microdev. 5 (2003) 21-27
    • (2003) Biomed. Microdev. , vol.5 , pp. 21-27
    • Malba, V.1    Maxwell, R.2    Evans, L.B.3    Bernhardt, A.F.4    Cosman, M.5    Yan, K.6
  • 10
    • 33750203807 scopus 로고    scopus 로고
    • Signal enhancement in HPLC/microcoil NMR using automated column trapping
    • Djukovic D., Liu S., Henry I., Tobias B., and Rafferty D. Signal enhancement in HPLC/microcoil NMR using automated column trapping. Anal. Chem. 78 (2006) 7154-7160
    • (2006) Anal. Chem. , vol.78 , pp. 7154-7160
    • Djukovic, D.1    Liu, S.2    Henry, I.3    Tobias, B.4    Rafferty, D.5
  • 17
    • 0035305997 scopus 로고    scopus 로고
    • Design and testing of high sensitivity microreceiver coil apparatus for nuclear magnetic resonance and imaging
    • Seeber D.A., Cooper R.L., Ciobanu L., and Pennington C.H. Design and testing of high sensitivity microreceiver coil apparatus for nuclear magnetic resonance and imaging. Rev. Sci. Inst. 72 (2001) 2171-2179
    • (2001) Rev. Sci. Inst. , vol.72 , pp. 2171-2179
    • Seeber, D.A.1    Cooper, R.L.2    Ciobanu, L.3    Pennington, C.H.4
  • 18
    • 0035386348 scopus 로고    scopus 로고
    • Analysis of multilayer radio frequency microcoils for nuclear magnetic resonance spectroscopy
    • Grant S.C., Murphy L.A., Magin R.L., and Friedman G. Analysis of multilayer radio frequency microcoils for nuclear magnetic resonance spectroscopy. IEEE Trans. Magn. 37 (2001) 2989-2998
    • (2001) IEEE Trans. Magn. , vol.37 , pp. 2989-2998
    • Grant, S.C.1    Murphy, L.A.2    Magin, R.L.3    Friedman, G.4
  • 20
    • 3042778580 scopus 로고    scopus 로고
    • High signal-to-noise-ratio in low-field NMR on a chip: simulations and experimental results
    • Wensink H., Hermes D.C., and van den Berg A. High signal-to-noise-ratio in low-field NMR on a chip: simulations and experimental results. 17th IEEE MEMS (2004) 407-410
    • (2004) 17th IEEE MEMS , pp. 407-410
    • Wensink, H.1    Hermes, D.C.2    van den Berg, A.3
  • 21
    • 17044439641 scopus 로고    scopus 로고
    • Miniature permanent magnet for table-top NMR
    • Moresi G., and Magin R.L. Miniature permanent magnet for table-top NMR. Concept. Magn. Res. 19B (2003) 35-43
    • (2003) Concept. Magn. Res. , vol.19 B , pp. 35-43
    • Moresi, G.1    Magin, R.L.2
  • 23
    • 33748747854 scopus 로고    scopus 로고
    • Single-sided mobile NMR with a Halbach magnet
    • Chang W.H., Chen J.H., and Hwang L.P. Single-sided mobile NMR with a Halbach magnet. Magn. Reson. Imag. 24 (2006) 1095-1102
    • (2006) Magn. Reson. Imag. , vol.24 , pp. 1095-1102
    • Chang, W.H.1    Chen, J.H.2    Hwang, L.P.3
  • 25
    • 13944253634 scopus 로고    scopus 로고
    • Integration of biaxial planar gradient coils and an RF microcoil for NMR flow imaging
    • Goloshevsky A.G., Walton J.H., Shutov M.V., and de Ropp J.S. Integration of biaxial planar gradient coils and an RF microcoil for NMR flow imaging. Meas. Sci. Technol. 16 (2005) 505-512
    • (2005) Meas. Sci. Technol. , vol.16 , pp. 505-512
    • Goloshevsky, A.G.1    Walton, J.H.2    Shutov, M.V.3    de Ropp, J.S.4
  • 26
    • 0018983463 scopus 로고
    • Design of permanent multipole magnets with oriented rare earth cobalt material
    • Halbach K. Design of permanent multipole magnets with oriented rare earth cobalt material. Nucl. Instrum. Method. 169 (1980) 1-10
    • (1980) Nucl. Instrum. Method. , vol.169 , pp. 1-10
    • Halbach, K.1
  • 29
    • 49549133678 scopus 로고
    • The signal-to-noise ratio of the nuclear magnetic resonance experiment
    • Hoult D.I., and Richards R.E. The signal-to-noise ratio of the nuclear magnetic resonance experiment. J. Magn. Reson. 24 (1976) 71-85
    • (1976) J. Magn. Reson. , vol.24 , pp. 71-85
    • Hoult, D.I.1    Richards, R.E.2
  • 30
    • 36149025974 scopus 로고
    • Thermal agitation of electricity in conductors
    • Johnson J.B. Thermal agitation of electricity in conductors. Phys. Rev. 32 (1928) 97-109
    • (1928) Phys. Rev. , vol.32 , pp. 97-109
    • Johnson, J.B.1
  • 31
    • 36149010109 scopus 로고
    • Thermal agitation of electric charge in conductors
    • Nyquist H. Thermal agitation of electric charge in conductors. Phys. Rev. 32 (1928) 110-113
    • (1928) Phys. Rev. , vol.32 , pp. 110-113
    • Nyquist, H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.