-
2
-
-
0001193195
-
A preliminary report on the use of prefabricated nylon weave in the repair of ventral hernia
-
Cumberland V.H. A preliminary report on the use of prefabricated nylon weave in the repair of ventral hernia. Med J Aust 1 (1952) 143
-
(1952)
Med J Aust
, vol.1
, pp. 143
-
-
Cumberland, V.H.1
-
3
-
-
0005455357
-
Materials for hernia repair
-
Scales J.T. Materials for hernia repair. Proc R Soc Med 46 (1953) 647
-
(1953)
Proc R Soc Med
, vol.46
, pp. 647
-
-
Scales, J.T.1
-
4
-
-
18144432436
-
Mechanical properties of synthetic implants used in the repair of prolapse and urinary incontinence in women: which is the ideal material?
-
Cosson M., Debodinance P., Boukerrou M., Chauvet M.P., Lobry P., Crepin G., et al. Mechanical properties of synthetic implants used in the repair of prolapse and urinary incontinence in women: which is the ideal material?. Int Urogynecol J Pelvic Floor Dysfunct 14 (2003) 169
-
(2003)
Int Urogynecol J Pelvic Floor Dysfunct
, vol.14
, pp. 169
-
-
Cosson, M.1
Debodinance, P.2
Boukerrou, M.3
Chauvet, M.P.4
Lobry, P.5
Crepin, G.6
-
5
-
-
34548456200
-
Use of nylon sling in urinary incontinence
-
Kraatz H. Use of nylon sling in urinary incontinence. Zentralbl Gynakol 75 (1953) 1486
-
(1953)
Zentralbl Gynakol
, vol.75
, pp. 1486
-
-
Kraatz, H.1
-
6
-
-
0027034084
-
Physical and biological characteristics of the main biomaterials used in pelvic surgery
-
Brun J.L., Bordenave L., Lefebvre F., Bareille R., Barbie C., Rouais F., et al. Physical and biological characteristics of the main biomaterials used in pelvic surgery. Biomed Mater Eng 2 (1992) 203
-
(1992)
Biomed Mater Eng
, vol.2
, pp. 203
-
-
Brun, J.L.1
Bordenave, L.2
Lefebvre, F.3
Bareille, R.4
Barbie, C.5
Rouais, F.6
-
7
-
-
0001945339
-
Classification of biomaterials and their related complications in abdominal wall hernia surgery
-
Amid P.K. Classification of biomaterials and their related complications in abdominal wall hernia surgery. Hernia 1 (1997) 15
-
(1997)
Hernia
, vol.1
, pp. 15
-
-
Amid, P.K.1
-
8
-
-
73049140175
-
Zur operativen Behandlung der weiblichen stress inkontinenz
-
Zoedler D. Zur operativen Behandlung der weiblichen stress inkontinenz. Z Urol 54 (1961) 355
-
(1961)
Z Urol
, vol.54
, pp. 355
-
-
Zoedler, D.1
-
9
-
-
0013931081
-
Appraisal of the Goebell-Frangenheim-Stoeckel sling procedure
-
Ridley J.H. Appraisal of the Goebell-Frangenheim-Stoeckel sling procedure. Am J Obstet Gynecol 95 (1966) 714
-
(1966)
Am J Obstet Gynecol
, vol.95
, pp. 714
-
-
Ridley, J.H.1
-
10
-
-
0018394603
-
Comparison of Marlex mesh and microporous teflon sheets when used for hernia repair in the experimental animal
-
Elliott M.P., and Juler G.L. Comparison of Marlex mesh and microporous teflon sheets when used for hernia repair in the experimental animal. Am J Surg 137 (1979) 342
-
(1979)
Am J Surg
, vol.137
, pp. 342
-
-
Elliott, M.P.1
Juler, G.L.2
-
11
-
-
0026528430
-
Inflammatory response to subcutaneously implanted Marlex and GORE-TEX in massively obese patients
-
Stockeld D., Granstrom L., Backman L., and Dahlgren S. Inflammatory response to subcutaneously implanted Marlex and GORE-TEX in massively obese patients. Biomaterials 13 (1992) 261
-
(1992)
Biomaterials
, vol.13
, pp. 261
-
-
Stockeld, D.1
Granstrom, L.2
Backman, L.3
Dahlgren, S.4
-
12
-
-
0020545865
-
A comparison of prosthetic materials used to repair abdominal wall defects
-
Jenkins S.D., Klamer T.W., Parteka J.J., and Condon R.E. A comparison of prosthetic materials used to repair abdominal wall defects. Surgery 94 (1983) 392
-
(1983)
Surgery
, vol.94
, pp. 392
-
-
Jenkins, S.D.1
Klamer, T.W.2
Parteka, J.J.3
Condon, R.E.4
-
13
-
-
0032802092
-
Foreign body reaction to meshes used for the repair of abdominal wall hernias
-
Klinge U., Klosterhalfen B., Muller M., and Schumpelick V. Foreign body reaction to meshes used for the repair of abdominal wall hernias. Eur J Surg 165 (1999) 665
-
(1999)
Eur J Surg
, vol.165
, pp. 665
-
-
Klinge, U.1
Klosterhalfen, B.2
Muller, M.3
Schumpelick, V.4
-
14
-
-
0034950473
-
Influence of different sling materials on connective tissue metabolism in stress incontinent women
-
Falconer C., Soderberg M., Blomgren B., and Ulmsten U. Influence of different sling materials on connective tissue metabolism in stress incontinent women. Int Urogynecol J Pelvic Floor Dysfunct, suppl. 12 (2001) S19
-
(2001)
Int Urogynecol J Pelvic Floor Dysfunct, suppl.
, vol.12
-
-
Falconer, C.1
Soderberg, M.2
Blomgren, B.3
Ulmsten, U.4
-
15
-
-
0242690087
-
Mechanical properties of urogynecologic implant materials
-
Dietz H.P., Vancaillie P., Svehla M., Walsh W., Steensma A.B., and Vancaillie T.G. Mechanical properties of urogynecologic implant materials. Int Urogynecol J Pelvic Floor Dysfunct 14 (2003) 239
-
(2003)
Int Urogynecol J Pelvic Floor Dysfunct
, vol.14
, pp. 239
-
-
Dietz, H.P.1
Vancaillie, P.2
Svehla, M.3
Walsh, W.4
Steensma, A.B.5
Vancaillie, T.G.6
-
16
-
-
13744260298
-
In vivo tension sustained by fascial sling in pubovaginal sling surgery for female stress urinary incontinence
-
Lin A.T., Wang S.J., Chen K.K., and Chang L.S. In vivo tension sustained by fascial sling in pubovaginal sling surgery for female stress urinary incontinence. J Urol 173 (2005) 894
-
(2005)
J Urol
, vol.173
, pp. 894
-
-
Lin, A.T.1
Wang, S.J.2
Chen, K.K.3
Chang, L.S.4
-
17
-
-
0023758623
-
A further assessment of the gauze hammock sling operation in the treatment of stress incontinence
-
Kersey J., Martin M.R., and Mishra P. A further assessment of the gauze hammock sling operation in the treatment of stress incontinence. Br J Obstet Gynaecol 95 (1988) 382
-
(1988)
Br J Obstet Gynaecol
, vol.95
, pp. 382
-
-
Kersey, J.1
Martin, M.R.2
Mishra, P.3
-
18
-
-
0028069727
-
Surgical treatment of urinary stress incontinence by a suburethral sling procedure using a Mersilene mesh graft
-
Guner H., Yildiz A., Erdem A., Erdem M., Tiftik Z., and Yildirim M. Surgical treatment of urinary stress incontinence by a suburethral sling procedure using a Mersilene mesh graft. Gynecol Obstet Invest 37 (1994) 52
-
(1994)
Gynecol Obstet Invest
, vol.37
, pp. 52
-
-
Guner, H.1
Yildiz, A.2
Erdem, A.3
Erdem, M.4
Tiftik, Z.5
Yildirim, M.6
-
19
-
-
0034914343
-
Mersilene mesh sling: short- and long-term clinical and urodynamic outcomes
-
Young S.B., Howard A.E., and Baker S.P. Mersilene mesh sling: short- and long-term clinical and urodynamic outcomes. Am J Obstet Gynecol 185 (2001) 32
-
(2001)
Am J Obstet Gynecol
, vol.185
, pp. 32
-
-
Young, S.B.1
Howard, A.E.2
Baker, S.P.3
-
20
-
-
0035154547
-
"Sandwich technique" for suburethral placement of Mersilene mesh sling during pubovaginal suspension surgery: preliminary results
-
Sousa-Escandon A. "Sandwich technique" for suburethral placement of Mersilene mesh sling during pubovaginal suspension surgery: preliminary results. Urology 57 (2001) 49
-
(2001)
Urology
, vol.57
, pp. 49
-
-
Sousa-Escandon, A.1
-
22
-
-
0028962208
-
A follow up of Silastic sling for genuine stress incontinence
-
Chin Y.K., and Stanton S.L. A follow up of Silastic sling for genuine stress incontinence. Br J Obstet Gynaecol 102 (1995) 143
-
(1995)
Br J Obstet Gynaecol
, vol.102
, pp. 143
-
-
Chin, Y.K.1
Stanton, S.L.2
-
23
-
-
1942510404
-
Experience with a bone anchor sling for treating female stress urinary incontinence: outcome at 30 months
-
Carbone A., Palleschi G., Ciavarella S., Morello P., Tomiselli G., Parascani R., et al. Experience with a bone anchor sling for treating female stress urinary incontinence: outcome at 30 months. BJU Int 93 (2004) 780
-
(2004)
BJU Int
, vol.93
, pp. 780
-
-
Carbone, A.1
Palleschi, G.2
Ciavarella, S.3
Morello, P.4
Tomiselli, G.5
Parascani, R.6
-
24
-
-
2942609820
-
High rate of vaginal extrusion of silicone-coated polyester sling
-
Comiter C.V., and Colegrove P.M. High rate of vaginal extrusion of silicone-coated polyester sling. Urology 63 (2004) 1066
-
(2004)
Urology
, vol.63
, pp. 1066
-
-
Comiter, C.V.1
Colegrove, P.M.2
-
25
-
-
84929336187
-
Multi-center prospective study of the long-term effectiveness of a silicone coated synthetic mesh sling
-
abstract 353
-
Govier F.E., Kobashi K.C., Comiter C., Jones P., Dakil S.E., James R., et al. Multi-center prospective study of the long-term effectiveness of a silicone coated synthetic mesh sling. J Urol, suppl. 171 (2004) 92. abstract 353
-
(2004)
J Urol, suppl.
, vol.171
, pp. 92
-
-
Govier, F.E.1
Kobashi, K.C.2
Comiter, C.3
Jones, P.4
Dakil, S.E.5
James, R.6
-
26
-
-
0032702975
-
Erosion of woven polyester pubovaginal sling
-
Kobashi K.C., Dmochowski R.R., Mee S.L., Mostwin J., Nitti V.W., Zimmern P.E., et al. Erosion of woven polyester pubovaginal sling. J Urol 162 (1999) 2070
-
(1999)
J Urol
, vol.162
, pp. 2070
-
-
Kobashi, K.C.1
Dmochowski, R.R.2
Mee, S.L.3
Mostwin, J.4
Nitti, V.W.5
Zimmern, P.E.6
-
27
-
-
0030064748
-
Postoperative catheterization, urinary retention, and permanent voiding dysfunction after polytetrafluoroethylene suburethral sling placement
-
Weinberger M.W., and Ostergard D.R. Postoperative catheterization, urinary retention, and permanent voiding dysfunction after polytetrafluoroethylene suburethral sling placement. Obstet Gynecol 87 (1996) 50
-
(1996)
Obstet Gynecol
, vol.87
, pp. 50
-
-
Weinberger, M.W.1
Ostergard, D.R.2
-
28
-
-
0032818815
-
Gore-Tex patch sling: 7 years later
-
Choe J.M., and Staskin D.R. Gore-Tex patch sling: 7 years later. Urology 54 (1999) 641
-
(1999)
Urology
, vol.54
, pp. 641
-
-
Choe, J.M.1
Staskin, D.R.2
-
29
-
-
0035702504
-
Polytetrafluoroethylene patch sling for type 2 or type 3 stress urinary incontinence
-
Yamada T., Kamata S., Nagahama K., Ichiyanagi N., Horiuchi S., and Saitoh H. Polytetrafluoroethylene patch sling for type 2 or type 3 stress urinary incontinence. Int J Urol 8 (2001) 675
-
(2001)
Int J Urol
, vol.8
, pp. 675
-
-
Yamada, T.1
Kamata, S.2
Nagahama, K.3
Ichiyanagi, N.4
Horiuchi, S.5
Saitoh, H.6
-
30
-
-
0036783609
-
Vaginal erosion caused by antibacterial mesh sling
-
Choe J.M. Vaginal erosion caused by antibacterial mesh sling. J Urol 168 (2002) 1504
-
(2002)
J Urol
, vol.168
, pp. 1504
-
-
Choe, J.M.1
-
31
-
-
0029117241
-
The polypropylene pubovaginal sling for the treatment of recurrent stress urinary incontinence
-
Morgan J.E., Heritz D.M., Stewart F.E., Connoly J.C., and Farrow G.A. The polypropylene pubovaginal sling for the treatment of recurrent stress urinary incontinence. J Urol 154 (1995) 1013
-
(1995)
J Urol
, vol.154
, pp. 1013
-
-
Morgan, J.E.1
Heritz, D.M.2
Stewart, F.E.3
Connoly, J.C.4
Farrow, G.A.5
-
32
-
-
0042738769
-
Broad based tension-free synthetic cling for stress urinary incontinence: 5-year outcome
-
Shah D.K., Paul E.M., Amukele S., Eisenberg E.R., and Badlani G.H. Broad based tension-free synthetic cling for stress urinary incontinence: 5-year outcome. J Urol 170 (2003) 849
-
(2003)
J Urol
, vol.170
, pp. 849
-
-
Shah, D.K.1
Paul, E.M.2
Amukele, S.3
Eisenberg, E.R.4
Badlani, G.H.5
-
33
-
-
0025616666
-
An integral theory of female urinary incontinence
-
Petros P.E., and Ulmsten U. An integral theory of female urinary incontinence. Acta Obstet Gynecol Scand 153 (1990) 7
-
(1990)
Acta Obstet Gynecol Scand
, vol.153
, pp. 7
-
-
Petros, P.E.1
Ulmsten, U.2
-
34
-
-
0028961579
-
Intravaginal slingplasty (IVS): an ambulatory surgical procedure for treatment of female urinary incontinence
-
Ulmsten U., and Petros P. Intravaginal slingplasty (IVS): an ambulatory surgical procedure for treatment of female urinary incontinence. Scand J Urol Nephrol 29 (1995) 75
-
(1995)
Scand J Urol Nephrol
, vol.29
, pp. 75
-
-
Ulmsten, U.1
Petros, P.2
-
35
-
-
33645072985
-
Biocompatible properties of surgical mesh using an animal model
-
Krause H.G., Galloway S.J., Khoo S.K., Lourie R., and Goh J.T. Biocompatible properties of surgical mesh using an animal model. Aust N Z J Obstet Gynaecol 46 (2006) 42
-
(2006)
Aust N Z J Obstet Gynaecol
, vol.46
, pp. 42
-
-
Krause, H.G.1
Galloway, S.J.2
Khoo, S.K.3
Lourie, R.4
Goh, J.T.5
-
36
-
-
0036186533
-
A nationwide analysis of complications associated with the tension-free vaginal tape (TVT) procedure
-
Kuuva N., and Nilsson C.G. A nationwide analysis of complications associated with the tension-free vaginal tape (TVT) procedure. Acta Obstet Gynecol Scand 81 (2002) 72
-
(2002)
Acta Obstet Gynecol Scand
, vol.81
, pp. 72
-
-
Kuuva, N.1
Nilsson, C.G.2
-
37
-
-
0034755971
-
Tension-free vaginal tape operation: results of the Austrian registry
-
Austrian Urogynecology Working Group
-
Tamussino K.F., Hanzal E., Kolle D., Ralph G., Riss P.A.a., and Austrian Urogynecology Working Group. Tension-free vaginal tape operation: results of the Austrian registry. Obstet Gynecol 98 (2001) 732
-
(2001)
Obstet Gynecol
, vol.98
, pp. 732
-
-
Tamussino, K.F.1
Hanzal, E.2
Kolle, D.3
Ralph, G.4
Riss, P.A.a.5
-
38
-
-
17144401489
-
Erosions and urinary retention following polypropylene synthetic sling: Australasian survey
-
Hammad F.T., Kennedy-Smith A., and Robinson R.G. Erosions and urinary retention following polypropylene synthetic sling: Australasian survey. Eur Urol 47 (2005) 641
-
(2005)
Eur Urol
, vol.47
, pp. 641
-
-
Hammad, F.T.1
Kennedy-Smith, A.2
Robinson, R.G.3
-
39
-
-
10044285238
-
A histologic and immunohistochemical analysis of defective vaginal healing after continence taping procedures: a prospective case-controlled pilot study
-
Wang A.C., Lee L.Y., Lin C.T., and Chen J.R. A histologic and immunohistochemical analysis of defective vaginal healing after continence taping procedures: a prospective case-controlled pilot study. Am J Obstet Gynecol 191 (2004) 1868
-
(2004)
Am J Obstet Gynecol
, vol.191
, pp. 1868
-
-
Wang, A.C.1
Lee, L.Y.2
Lin, C.T.3
Chen, J.R.4
-
40
-
-
27244445037
-
Tension-free vaginal tape exposure presenting as a recurrent sterile paraurethral abscess
-
Tate S.B., Franco A.V., and Fynes M.M. Tension-free vaginal tape exposure presenting as a recurrent sterile paraurethral abscess. Int Urogynecol J Pelvic Floor Dysfunct 16 (2005) 420
-
(2005)
Int Urogynecol J Pelvic Floor Dysfunct
, vol.16
, pp. 420
-
-
Tate, S.B.1
Franco, A.V.2
Fynes, M.M.3
-
41
-
-
1342326622
-
Suburethral vaginal erosion and pyogenic granuloma formation: an unusual complication of intravaginal slingplasty (IVS)
-
Lim Y.N., and Rane A. Suburethral vaginal erosion and pyogenic granuloma formation: an unusual complication of intravaginal slingplasty (IVS). Int Urogynecol J Pelvic Floor Dysfunct 15 (2004) 56
-
(2004)
Int Urogynecol J Pelvic Floor Dysfunct
, vol.15
, pp. 56
-
-
Lim, Y.N.1
Rane, A.2
-
42
-
-
2942748310
-
Erosion, defective healing and extrusion after tension-free urethropexy for the treatment of stress urinary incontinence
-
Glavind K., and Sander P. Erosion, defective healing and extrusion after tension-free urethropexy for the treatment of stress urinary incontinence. Int Urogynecol J Pelvic Floor Dysfunct 15 (2004) 179
-
(2004)
Int Urogynecol J Pelvic Floor Dysfunct
, vol.15
, pp. 179
-
-
Glavind, K.1
Sander, P.2
-
43
-
-
33750307227
-
Tension-free vaginal tape (TVT) and intravaginal slingplasty (IVS) for stress urinary incontinence: a multicenter randomized trial
-
Meschia M., Pifarotti P., Bernasconi F., Magatti F., Vigano R., Bertozzi R., et al. Tension-free vaginal tape (TVT) and intravaginal slingplasty (IVS) for stress urinary incontinence: a multicenter randomized trial. Am J Obstet Gynecol 195 (2006) 1338
-
(2006)
Am J Obstet Gynecol
, vol.195
, pp. 1338
-
-
Meschia, M.1
Pifarotti, P.2
Bernasconi, F.3
Magatti, F.4
Vigano, R.5
Bertozzi, R.6
-
44
-
-
33746910203
-
How common are tape erosions?. A comparison of two versions of the transobturator tension-free vaginal tape procedure
-
Abdel-Fattah M., Sivanesan K., Ramsay I., Pringle S., and Bjornsson S. How common are tape erosions?. A comparison of two versions of the transobturator tension-free vaginal tape procedure. BJU Int 98 (2006) 594
-
(2006)
BJU Int
, vol.98
, pp. 594
-
-
Abdel-Fattah, M.1
Sivanesan, K.2
Ramsay, I.3
Pringle, S.4
Bjornsson, S.5
-
45
-
-
33745233049
-
High rate of vaginal erosions associated with the Mentor ObTape
-
Yamada B.S., Govier F.E., Stefanovic K.B., and Kobashi K.C. High rate of vaginal erosions associated with the Mentor ObTape. J Urol 176 (2006) 651
-
(2006)
J Urol
, vol.176
, pp. 651
-
-
Yamada, B.S.1
Govier, F.E.2
Stefanovic, K.B.3
Kobashi, K.C.4
-
46
-
-
32044459338
-
Objective and subjective cure rates after trans-obturator tape (ObTape) treatment of female urinary incontinence
-
Deval B., Ferchaux J., Berry R., Gambino S., Ciofu C., Rafii A., et al. Objective and subjective cure rates after trans-obturator tape (ObTape) treatment of female urinary incontinence. Eur Urol 49 (2006) 373
-
(2006)
Eur Urol
, vol.49
, pp. 373
-
-
Deval, B.1
Ferchaux, J.2
Berry, R.3
Gambino, S.4
Ciofu, C.5
Rafii, A.6
-
47
-
-
33846566758
-
Transobturator tape (TOT): two years follow-up
-
Juma S., and Brito C.G. Transobturator tape (TOT): two years follow-up. Neurourol Urodyn 26 (2007) 37
-
(2007)
Neurourol Urodyn
, vol.26
, pp. 37
-
-
Juma, S.1
Brito, C.G.2
-
48
-
-
33748104715
-
Obturator abscess after transobturator tape for stress urinary incontinence
-
Rafii A., Jacob D., and Deval B. Obturator abscess after transobturator tape for stress urinary incontinence. Obstet Gynecol 108 (2006) 720
-
(2006)
Obstet Gynecol
, vol.108
, pp. 720
-
-
Rafii, A.1
Jacob, D.2
Deval, B.3
-
49
-
-
33845940888
-
Severe soft tissue infection of the thigh after vaginal erosion of transobturator tape for stress urinary incontinence
-
Karsenty G., Boman J., Elzayat E., Lemieux M.C., and Corcos J. Severe soft tissue infection of the thigh after vaginal erosion of transobturator tape for stress urinary incontinence. Int Urogynecol J Pelvic Floor Dysfunct 18 (2007) 207
-
(2007)
Int Urogynecol J Pelvic Floor Dysfunct
, vol.18
, pp. 207
-
-
Karsenty, G.1
Boman, J.2
Elzayat, E.3
Lemieux, M.C.4
Corcos, J.5
-
50
-
-
33744791451
-
Vaginal erosion, sinus formation, and ischiorectal abscess following transobturator tape: ObTape implantation
-
Babalola E.O., Famuyide A.O., McGuire L.J., Gebhart J.B., and Klingele C.J. Vaginal erosion, sinus formation, and ischiorectal abscess following transobturator tape: ObTape implantation. Int Urogynecol J Pelvic Floor Dysfunct 17 (2006) 418
-
(2006)
Int Urogynecol J Pelvic Floor Dysfunct
, vol.17
, pp. 418
-
-
Babalola, E.O.1
Famuyide, A.O.2
McGuire, L.J.3
Gebhart, J.B.4
Klingele, C.J.5
|