메뉴 건너뛰기




Volumn 21, Issue 7, 2007, Pages 427-434

The effect of C-arm malrotation on iliosacral screw placement

Author keywords

Fluoroscopic guidance; Pelvic ring; Percutaneous fixation; Sacral screw

Indexed keywords

ARM; ARTICLE; AUDIOVISUAL EQUIPMENT; CADAVER; FLUOROSCOPY; GUIDE WIRE; HUMAN; PELVIS; POSITION; PRIORITY JOURNAL; ROTATION; SACROILIAC JOINT; SACRUM; WIRE FIXATION;

EID: 34548379900     PISSN: 08905339     EISSN: None     Source Type: Journal    
DOI: 10.1097/BOT.0b013e318137948d     Document Type: Article
Times cited : (31)

References (13)
  • 1
    • 0032455890 scopus 로고    scopus 로고
    • Iliosacral screw insertion using computer-assisted CT image guidance: A laboratory study
    • Barrick EF, O'Mara JW, Lane HE. Iliosacral screw insertion using computer-assisted CT image guidance: a laboratory study. Computer Aided Surgery. 1998:3:289-296.
    • (1998) Computer Aided Surgery , vol.3 , pp. 289-296
    • Barrick, E.F.1    O'Mara, J.W.2    Lane, H.E.3
  • 2
    • 0034183944 scopus 로고    scopus 로고
    • Safe placement of S1 and S2 screws: The "vestibule" concept
    • Carlson DA, Scheid KD, Marr DC, et al. Safe placement of S1 and S2 screws: the "vestibule" concept. J Orthop Trauma. 2000;14:264-269.
    • (2000) J Orthop Trauma , vol.14 , pp. 264-269
    • Carlson, D.A.1    Scheid, K.D.2    Marr, D.C.3
  • 3
    • 0029880263 scopus 로고    scopus 로고
    • Projection of the S2 pedicle onto the posterolateral surface of the ilium
    • Cecil ML, Rollins JR, Ebraheim NA, et al. Projection of the S2 pedicle onto the posterolateral surface of the ilium. Spine. 1996;21:875-878.
    • (1996) Spine , vol.21 , pp. 875-878
    • Cecil, M.L.1    Rollins, J.R.2    Ebraheim, N.A.3
  • 4
    • 0032033101 scopus 로고    scopus 로고
    • Imaging assessment of sacroiliac screw placement relative to the neuroforamen
    • Goldberg BA, Lindsey RW, Folgar C, et al. Imaging assessment of sacroiliac screw placement relative to the neuroforamen. Spine. 1998;23:585-589.
    • (1998) Spine , vol.23 , pp. 585-589
    • Goldberg, B.A.1    Lindsey, R.W.2    Folgar, C.3
  • 5
    • 0027727671 scopus 로고
    • Posterior sacroiliac fixation using a sacral pedicle targeting device: An anatomical study
    • Miller MD, Cain JE, Lauerman WC, et al. Posterior sacroiliac fixation using a sacral pedicle targeting device: an anatomical study. J Orthop Trauma. 1993;7:514-520.
    • (1993) J Orthop Trauma , vol.7 , pp. 514-520
    • Miller, M.D.1    Cain, J.E.2    Lauerman, W.C.3
  • 6
    • 0036172601 scopus 로고    scopus 로고
    • Fluoroscopy-based multiplanar image guidance for insertion of sacroiliac screws
    • Hinsche AF, Giannoudis PV, Smith RM. Fluoroscopy-based multiplanar image guidance for insertion of sacroiliac screws. CORR. 2001;395:135-144.
    • (2001) CORR , vol.395 , pp. 135-144
    • Hinsche, A.F.1    Giannoudis, P.V.2    Smith, R.M.3
  • 7
    • 0037323047 scopus 로고    scopus 로고
    • The effect of sacral fracture malreduction on the safe placement of iliosacral screws
    • Reilly MC, Bono CM, Litkouhi B, et al. The effect of sacral fracture malreduction on the safe placement of iliosacral screws. J Orthop Trauma. 2003;17:88-94.
    • (2003) J Orthop Trauma , vol.17 , pp. 88-94
    • Reilly, M.C.1    Bono, C.M.2    Litkouhi, B.3
  • 8
    • 0029689344 scopus 로고    scopus 로고
    • Radiographic recognition of the sacral alar slope for optimal placement of iliosacral screws: A cadaveric and clinical study
    • Routt ML, Simonian PT, Agnew SG, et al. Radiographic recognition of the sacral alar slope for optimal placement of iliosacral screws: a cadaveric and clinical study. J Orthop Trauma. 1996;10:171-177.
    • (1996) J Orthop Trauma , vol.10 , pp. 171-177
    • Routt, M.L.1    Simonian, P.T.2    Agnew, S.G.3
  • 9
    • 0343239081 scopus 로고    scopus 로고
    • Percutaneous fixation of pelvic ring disruptions
    • Routt MLC, Nork SE, Mills WJ. Percutaneous fixation of pelvic ring disruptions. CORR. 2000;375:15-29.
    • (2000) CORR , vol.375 , pp. 15-29
    • Routt, M.L.C.1    Nork, S.E.2    Mills, W.J.3
  • 10
    • 0029918309 scopus 로고    scopus 로고
    • Radiologic evaluation of iliosacral screw placement
    • Xu R, Ebraheim N, Robke J, et al. Radiologic evaluation of iliosacral screw placement. Spine. 1996;21:582-588.
    • (1996) Spine , vol.21 , pp. 582-588
    • Xu, R.1    Ebraheim, N.2    Robke, J.3
  • 11
    • 0036633039 scopus 로고    scopus 로고
    • Fluoroscopic positioning of sacroiliac screws in 88 patients
    • Van den Bosch EW, van Zwienen MA, van Vugt AB. Fluoroscopic positioning of sacroiliac screws in 88 patients. J Trauma. 2002;53:44-48.
    • (2002) J Trauma , vol.53 , pp. 44-48
    • Van den Bosch, E.W.1    van Zwienen, M.A.2    van Vugt, A.B.3
  • 12
    • 0003902447 scopus 로고    scopus 로고
    • Tile M, ed, 3rd ed. Philadelphia: Williams and Wilkins;
    • Tile M, ed. Fractures of the pelvis and acetabulum. 3rd ed. Philadelphia: Williams and Wilkins; 2003:231-243.
    • (2003) Fractures of the pelvis and acetabulum , pp. 231-243
  • 13
    • 14844336330 scopus 로고    scopus 로고
    • Inadvertent intraforaminal iliosacral screw placement despite apparent appropriate positioning on intraoperative fluoroscopy
    • Sagi HC, Lindvall EM. Inadvertent intraforaminal iliosacral screw placement despite apparent appropriate positioning on intraoperative fluoroscopy. J Orthop Trauma. 2005:19:190-193.
    • (2005) J Orthop Trauma , vol.19 , pp. 190-193
    • Sagi, H.C.1    Lindvall, E.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.