메뉴 건너뛰기




Volumn 16, Issue 5, 2007, Pages 343-351

Surface quality and long-term dimensional stability of current elastomeric ipression materials after disinfection: Basic science research

Author keywords

Dimensional accuracy; Disinfection; Hydrophilic; Polyether; Surface detail; Vinylpolysiloxane

Indexed keywords

AQUASIL; BIOMEDICAL AND DENTAL MATERIALS; DISINFECTANT AGENT; HYPOCHLORITE SODIUM; POLYVINYL DERIVATIVE; RESIN; SILOXANE; UNCLASSIFIED DRUG;

EID: 34548358981     PISSN: 1059941X     EISSN: 1532849X     Source Type: Journal    
DOI: 10.1111/j.1532-849X.2007.00206.x     Document Type: Article
Times cited : (43)

References (37)
  • 1
    • 0027925324 scopus 로고
    • Recommended infection-control practices for dentistry
    • Centers for Disease Control and Prevention:
    • Centers for Disease Control and Prevention : Recommended infection-control practices for dentistry. MMWR Morb Mortal Wkly Rpt 1993 42 (RR-8 1 12
    • (1993) MMWR Morb Mortal Wkly Rpt , vol.42 , Issue.8 , pp. 1-12
  • 2
    • 0030140087 scopus 로고    scopus 로고
    • Infection control recommendations for the dental office and the dental laboratory
    • ADA Council on Scientific Affairs and ADA Council on Dental Practice:
    • ADA Council on Scientific Affairs and ADA Council on Dental Practice : Infection control recommendations for the dental office and the dental laboratory. J Am Dent Assoc 1996 127 : 672 680
    • (1996) J Am Dent Assoc , vol.127 , pp. 672-680
  • 3
    • 0023957649 scopus 로고
    • Infection control recommendations for the dental office and the dental laboratory
    • Council on Dental Materials, Instruments, and Equipment, Council on Dental Practice, and Council on Dental Therapeutics:
    • Council on Dental Materials, Instruments, and Equipment, Council on Dental Practice, and Council on Dental Therapeutics : Infection control recommendations for the dental office and the dental laboratory. J Am Dent Assoc 1988 116 : 241 248
    • (1988) J Am Dent Assoc , vol.116 , pp. 241-248
  • 4
    • 0026904905 scopus 로고
    • Infection control recommendations for the dental office and the dental laboratory
    • Council on Dental Materials, Instruments, and Equipment, and Council on Dental Therapeutics:
    • Council on Dental Materials, Instruments, and Equipment, and Council on Dental Therapeutics : Infection control recommendations for the dental office and the dental laboratory. J Am Dent Assoc 1992 Aug Suppl) : 1 8
    • (1992) J Am Dent Assoc , pp. 1-8
  • 5
    • 0025462819 scopus 로고
    • Disinfection/sterilization protocols recommended by manufacturers of impression materials
    • Cottone JA, Young JM, Dinyarian P : Disinfection/sterilization protocols recommended by manufacturers of impression materials. Int J Prosthodont 1990 3 : 379 383
    • (1990) Int J Prosthodont , vol.3 , pp. 379-383
    • Cottone, J.A.1    Young, J.M.2    Dinyarian, P.3
  • 6
    • 34548351836 scopus 로고    scopus 로고
    • Organization for Safety and Asepsis Procedures: Annapolis, MD, OSAP
    • Organization for Safety and Asepsis Procedures : Chemical Agents for Surface Disinfection. Annapolis, MD, OSAP, 1998
    • (1998) Chemical Agents for Surface Disinfection.
  • 7
    • 0029348748 scopus 로고
    • Surface characteristics of polyether and addition silicone impression materials after long-term disinfection
    • Lepe X, Johnson GH, Berg JC : Surface characteristics of polyether and addition silicone impression materials after long-term disinfection. J Prosthet Dent 1995 74 : 181 186
    • (1995) J Prosthet Dent , vol.74 , pp. 181-186
    • Lepe, X.1    Johnson, G.H.2    Berg, J.C.3
  • 8
    • 0019294450 scopus 로고
    • Elastomeric impression materials. Dimensional stability and surface detail sharpness following treatment with disinfection solutions
    • Bergman M, Olsson S, Bergman B : Elastomeric impression materials. Dimensional stability and surface detail sharpness following treatment with disinfection solutions. Swed Dent J 1980 4 : 161 167
    • (1980) Swed Dent J , vol.4 , pp. 161-167
    • Bergman, M.1    Olsson, S.2    Bergman, B.3
  • 9
    • 0029241017 scopus 로고
    • Evaluation of dimensional stability of elastomeric impression materials during disinfection
    • Oda Y, Matsumoto T, Sumii T : Evaluation of dimensional stability of elastomeric impression materials during disinfection. Bull Tokyo Dent Coll 1995 36 : 1 7
    • (1995) Bull Tokyo Dent Coll , vol.36 , pp. 1-7
    • Oda, Y.1    Matsumoto, T.2    Sumii, T.3
  • 10
    • 0036725770 scopus 로고    scopus 로고
    • Wettability, imbibition, and mass change of disinfected low-viscosity impression materials
    • Lepe X, Johnson GH, Berg JC, et al : Wettability, imbibition, and mass change of disinfected low-viscosity impression materials. J Prosthet Dent 2002 88 : 268 276
    • (2002) J Prosthet Dent , vol.88 , pp. 268-276
    • Lepe, X.1    Johnson, G.H.2    Berg, J.C.3    Al, E.4
  • 11
    • 0031226790 scopus 로고    scopus 로고
    • Accuracy of polyether and addition silicone after long-term immersion disinfection
    • Lepe X, Johnson GH : Accuracy of polyether and addition silicone after long-term immersion disinfection. J Prosthet Dent 1997 78 : 245 249
    • (1997) J Prosthet Dent , vol.78 , pp. 245-249
    • Lepe, X.1    Johnson, G.H.2
  • 12
    • 0025391509 scopus 로고
    • The dimensional stability of elastomeric impression materials following disinfection
    • Langenwalter EM, Aquilino SA, Turner KA : The dimensional stability of elastomeric impression materials following disinfection. J Prosthet Dent 1990 63 : 270 276
    • (1990) J Prosthet Dent , vol.63 , pp. 270-276
    • Langenwalter, E.M.1    Aquilino, S.A.2    Turner, K.A.3
  • 13
    • 0033124328 scopus 로고    scopus 로고
    • Effect of disinfectant agents on dimensional stability of elastomeric impression materials
    • Adabo GL, Zanarotti E, Fonseca RG, et al : Effect of disinfectant agents on dimensional stability of elastomeric impression materials. J Prosthet Dent 1999 81 : 621 624
    • (1999) J Prosthet Dent , vol.81 , pp. 621-624
    • Adabo, G.L.1    Zanarotti, E.2    Fonseca, R.G.3    Al, E.4
  • 14
    • 0032150856 scopus 로고    scopus 로고
    • The effect of disinfecting alginate and addition cured silicone rubber impression materials on the physical properties of impressions and resultant casts
    • al-Omari WM, Jones JC, Wood DJ : The effect of disinfecting alginate and addition cured silicone rubber impression materials on the physical properties of impressions and resultant casts. Eur J Prosthodont Restor Dent 1998 6 : 103 110
    • (1998) Eur J Prosthodont Restor Dent , vol.6 , pp. 103-110
    • Al-Omari, W.M.1    Jones, J.C.2    Wood, D.J.3
  • 15
    • 0028399289 scopus 로고
    • Effect of immersion disinfection on properties of impression materials
    • Davis BA, Powers JM : Effect of immersion disinfection on properties of impression materials. J Prosthodont 1994 3 : 31 34
    • (1994) J Prosthodont , vol.3 , pp. 31-34
    • Davis, B.A.1    Powers, J.M.2
  • 16
    • 0024985509 scopus 로고
    • Dimensional stability of impression materials immersed in an iodophor disinfectant
    • Giblin J, Podesta R, White J : Dimensional stability of impression materials immersed in an iodophor disinfectant. Int J Prosthodont 1990 3 : 72 77
    • (1990) Int J Prosthodont , vol.3 , pp. 72-77
    • Giblin, J.1    Podesta, R.2    White, J.3
  • 17
    • 0022779611 scopus 로고
    • Dimensional stability of dental impressions after immersion disinfection
    • Herrera SP, Merchant VA : Dimensional stability of dental impressions after immersion disinfection. J Am Dent Assoc 1986 113 : 419 422
    • (1986) J Am Dent Assoc , vol.113 , pp. 419-422
    • Herrera, S.P.1    Merchant, V.A.2
  • 18
    • 14544291628 scopus 로고    scopus 로고
    • The effect of a range of disinfectants on the dimensional accuracy of some impression materials
    • Jagger DC, Al Jabra O, Harrison A, et al : The effect of a range of disinfectants on the dimensional accuracy of some impression materials. Eur J Prosthodont Restor Dent 2004 12 : 154 160
    • (2004) Eur J Prosthodont Restor Dent , vol.12 , pp. 154-160
    • Jagger, D.C.1    Al Jabra, O.2    Harrison, A.3    Al, E.4
  • 19
    • 0032044384 scopus 로고    scopus 로고
    • Dimensional stability and detail reproduction of irreversible hydrocolloid and elastomeric impressions disinfected by immersion
    • Johnson GH, Chellis KD, Gordon GE, et al : Dimensional stability and detail reproduction of irreversible hydrocolloid and elastomeric impressions disinfected by immersion. J Prosthet Dent 1998 79 : 446 453
    • (1998) J Prosthet Dent , vol.79 , pp. 446-453
    • Johnson, G.H.1    Chellis, K.D.2    Gordon, G.E.3    Al, E.4
  • 20
    • 0023991221 scopus 로고
    • Accuracy of elastomeric impressions disinfected by immersion
    • Johnson GH, Drennon DG, Powell GL : Accuracy of elastomeric impressions disinfected by immersion. J Am Dent Assoc 1988 116 : 525 530
    • (1988) J Am Dent Assoc , vol.116 , pp. 525-530
    • Johnson, G.H.1    Drennon, D.G.2    Powell, G.L.3
  • 21
    • 27744495442 scopus 로고    scopus 로고
    • Moisture effect on polyether and polyvinylsiloxane dimensional accuracy and detail reproduction
    • Walker MP, Petrie CS, Haj-Ali R, et al : Moisture effect on polyether and polyvinylsiloxane dimensional accuracy and detail reproduction. J Prosthodont 2005 14 : 158 163
    • (2005) J Prosthodont , vol.14 , pp. 158-163
    • Walker, M.P.1    Petrie, C.S.2    Haj-Ali, R.3    Al, E.4
  • 22
    • 0026253217 scopus 로고
    • Wettability of nonaqueous elastomeric impression materials
    • Chai JY, Yeung TC : Wettability of nonaqueous elastomeric impression materials. Int J Prosthodont 1991 4 : 555 560
    • (1991) Int J Prosthodont , vol.4 , pp. 555-560
    • Chai, J.Y.1    Yeung, T.C.2
  • 25
    • 4143144368 scopus 로고    scopus 로고
    • Mechanical properties of 3 hydrophilic addition silicone and polyether elastomeric impression materials
    • Lu H, Nguyen B, Powers JM : Mechanical properties of 3 hydrophilic addition silicone and polyether elastomeric impression materials. J Prosthet Dent 2004 92 : 151 154
    • (2004) J Prosthet Dent , vol.92 , pp. 151-154
    • Lu, H.1    Nguyen, B.2    Powers, J.M.3
  • 29
    • 34548361295 scopus 로고    scopus 로고
    • Coltene Whaledent Inc: Impression materials. cited. Available at
    • Coltene Whaledent Inc: Impression materials cited 2005 Dec 20 Available at http://www.coltenewhaledent.com
    • (2005)
  • 30
    • 34548369688 scopus 로고    scopus 로고
    • GC America, Inc: Impression materials. cited. Available at
    • GC America, Inc: Impression materials cited 2005 Dec 20 Available at http://www.gcamerica.com
    • (2005)
  • 31
    • 0017484453 scopus 로고
    • ANSI/ADA: American National Standards Institute/American Dental Association: Specification No. 19 for non-aqueous, elastomeric dental impressions. addendum 1982;1105:1686
    • ANSI/ADA: American National Standards Institute/American Dental Association: Specification No. 19 for non-aqueous, elastomeric dental impressions. J Am Dent Assoc 1977 94 : 733 741 addendum 1982;1105:1686
    • (1977) J Am Dent Assoc , vol.94 , pp. 733-741
  • 32
    • 0024692196 scopus 로고
    • Interaction of gloves and rubber dam with a poly(vinyl siloxane) impression material: A screening test
    • Kahn RL, Donovan TE, Chee WW : Interaction of gloves and rubber dam with a poly(vinyl siloxane) impression material: a screening test. Int J Prosthodont 1989 2 : 342 346
    • (1989) Int J Prosthodont , vol.2 , pp. 342-346
    • Kahn, R.L.1    Donovan, T.E.2    Chee, W.W.3
  • 34
    • 0023972613 scopus 로고
    • The dimensional accuracy of improved dental stone, silverplated, and epoxy resin die materials
    • Bailey JH, Donovan TE, Preston JD : The dimensional accuracy of improved dental stone, silverplated, and epoxy resin die materials. J Prosthet Dent 1988 59 : 307 310
    • (1988) J Prosthet Dent , vol.59 , pp. 307-310
    • Bailey, J.H.1    Donovan, T.E.2    Preston, J.D.3
  • 35
    • 20444364152 scopus 로고    scopus 로고
    • Accuracy of newly formulated fast-setting elastomeric impression materials
    • Wadhwani CP, Johnson GH, Lepe X, et al : Accuracy of newly formulated fast-setting elastomeric impression materials. J Prosthet Dent 2005 93 : 530 539
    • (2005) J Prosthet Dent , vol.93 , pp. 530-539
    • Wadhwani, C.P.1    Johnson, G.H.2    Lepe, X.3    Al, E.4
  • 36
    • 0032488231 scopus 로고    scopus 로고
    • In vitro aging of dental composites in water-effect of degree of conversion, filler volume, and filler/matrix coupling
    • Ferracane JL, Berge HX, Condon JR : In vitro aging of dental composites in water-effect of degree of conversion, filler volume, and filler/matrix coupling. J Biomed Mater Res 1998 42 : 465 472
    • (1998) J Biomed Mater Res , vol.42 , pp. 465-472
    • Ferracane, J.L.1    Berge, H.X.2    Condon, J.R.3
  • 37
    • 84972698582 scopus 로고
    • Effect of filler content and size on properties of composites
    • Li Y, Swartz ML, Phillips RW, et al : Effect of filler content and size on properties of composites. J Dent Res 1985 64 : 1396 1401.
    • (1985) J Dent Res , vol.64 , pp. 1396-1401
    • Li, Y.1    Swartz, M.L.2    Phillips, R.W.3    Al, E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.