메뉴 건너뛰기




Volumn 42, Issue 4-5, 2007, Pages 621-624

Synthesis and physical characteristics of radiophotoluminescent glass dosimeters

Author keywords

Laser; Radiation dose; Radiophotoluminescent glass dosimeter

Indexed keywords

DOSIMETRY; GLASS; LASER EXCITATION; LUMINESCENT DEVICES; PHOTOLUMINESCENCE; READOUT SYSTEMS;

EID: 34548281692     PISSN: 13504487     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radmeas.2007.01.053     Document Type: Article
Times cited : (39)

References (8)
  • 1
    • 0041387395 scopus 로고    scopus 로고
    • Measurements of gamma-knife helmet output factors using a radiophotoluminescent glass rod dosimeter and a diode detector
    • Araki F., Ikegami T., Ishidoya T., and Kubo H.D. Measurements of gamma-knife helmet output factors using a radiophotoluminescent glass rod dosimeter and a diode detector. Med. Phys. 30 (2004) 1976-1981
    • (2004) Med. Phys. , vol.30 , pp. 1976-1981
    • Araki, F.1    Ikegami, T.2    Ishidoya, T.3    Kubo, H.D.4
  • 2
    • 34548234290 scopus 로고    scopus 로고
    • Asahi Techno Glass Corporation, 2004. RPL glass dosemeter-small element system, Tokyo, Japan.
  • 3
    • 84937665088 scopus 로고
    • Stability of radiophotoluminescence in metaphosphate glass
    • Cheka J.S. Stability of radiophotoluminescence in metaphosphate glass. Health Phys. 10 (1964) 363-368
    • (1964) Health Phys. , vol.10 , pp. 363-368
    • Cheka, J.S.1
  • 4
    • 0030189313 scopus 로고    scopus 로고
    • The influence of glass composition on properties of silver-doped radiophotoluminescent phosphate glasses
    • Dmitryuk A.V., Paramzina S.E., Perminov A.S., Solov'eva N.D., and Timofeev N.T. The influence of glass composition on properties of silver-doped radiophotoluminescent phosphate glasses. J. Non-cryst. Solids 202 (1996) 173-177
    • (1996) J. Non-cryst. Solids , vol.202 , pp. 173-177
    • Dmitryuk, A.V.1    Paramzina, S.E.2    Perminov, A.S.3    Solov'eva, N.D.4    Timofeev, N.T.5
  • 5
    • 0022881597 scopus 로고
    • Properties of radiophotoluminescencent glass dosemeter systems using pulsed laser UV excitation
    • Piesch E., Burgkhardt B., Fischer M., Rober H.G., and Ugi S. Properties of radiophotoluminescencent glass dosemeter systems using pulsed laser UV excitation. Radiat. Prot. Dosim. 17 (1986) 293-297
    • (1986) Radiat. Prot. Dosim. , vol.17 , pp. 293-297
    • Piesch, E.1    Burgkhardt, B.2    Fischer, M.3    Rober, H.G.4    Ugi, S.5
  • 7
    • 13844294381 scopus 로고    scopus 로고
    • In vivo dosimetry of high-dose-rate brachytherapy: study on 61 head-and-neck cancer patients using radiophotoluminescence glass dosimeter
    • Takayuki N., Masahiko K., Ken Y., Kinji N., Junichi S., Takeshi O., and Didier P. In vivo dosimetry of high-dose-rate brachytherapy: study on 61 head-and-neck cancer patients using radiophotoluminescence glass dosimeter. Int. J. Radiat. Oncol. Biol. Phys. 61 (2005) 945-953
    • (2005) Int. J. Radiat. Oncol. Biol. Phys. , vol.61 , pp. 945-953
    • Takayuki, N.1    Masahiko, K.2    Ken, Y.3    Kinji, N.4    Junichi, S.5    Takeshi, O.6    Didier, P.7
  • 8
    • 0015072974 scopus 로고
    • Silver-activated phosphate dosimeter glasses with low energy dependence and higher sensitivity
    • Yokota R., and Muto Y. Silver-activated phosphate dosimeter glasses with low energy dependence and higher sensitivity. Health Phys. 20 (1971) 662-663
    • (1971) Health Phys. , vol.20 , pp. 662-663
    • Yokota, R.1    Muto, Y.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.