메뉴 건너뛰기




Volumn 10, Issue 3, 2007, Pages 34-39

Microwave measurements Part II: Non-linear measurements

Author keywords

[No Author keywords available]

Indexed keywords

DIRECTIONAL COUPLERS; ERROR CORRECTION; MULTIPLEXING EQUIPMENT; NONLINEAR ANALYSIS;

EID: 34548273073     PISSN: 10946969     EISSN: None     Source Type: Journal    
DOI: 10.1109/MIM.2007.4284255     Document Type: Article
Times cited : (42)

References (11)
  • 1
    • 34249887376 scopus 로고    scopus 로고
    • Microwave Measurements. Part I - Linear Measurements
    • Apr
    • M. Pirola, V. Teppati, and V. Camarchia, "Microwave Measurements. Part I - Linear Measurements," IEEE Instrum. Meas. Mag., vol. 10, (no. 2), pp. 26-38, Apr. 2007.
    • (2007) IEEE Instrum. Meas. Mag , vol.10 , Issue.2 , pp. 26-38
    • Pirola, M.1    Teppati, V.2    Camarchia, V.3
  • 4
    • 0020907442 scopus 로고
    • A computer controlled microwave tuner for automated load-pull
    • Dec
    • F. Sechi, R. Paglione, B. Perlman, and J. Brown, "A computer controlled microwave tuner for automated load-pull," RCA Review, vol. 44, pp. 566-572, Dec. 1983.
    • (1983) RCA Review , vol.44 , pp. 566-572
    • Sechi, F.1    Paglione, R.2    Perlman, B.3    Brown, J.4
  • 5
    • 85024343374 scopus 로고
    • A new load-pull characterization method for microwave power transistor
    • Y. Takayama, "A new load-pull characterization method for microwave power transistor," in IEEE MTT-S Intl. Microwave Symp. Dig., 1976, pp. 218-220.
    • (1976) IEEE MTT-S Intl. Microwave Symp. Dig , pp. 218-220
    • Takayama, Y.1
  • 6
    • 0020091250 scopus 로고
    • Active load technique for load-pull characterization at microwave frequencies
    • Feb
    • G.P. Bava, U. Pisani, and V. Pozzolo, "Active load technique for load-pull characterization at microwave frequencies," Electronic Lett., vol. 18, pp. 178-179, Feb. 1982.
    • (1982) Electronic Lett , vol.18 , pp. 178-179
    • Bava, G.P.1    Pisani, U.2    Pozzolo, V.3
  • 7
    • 34548215130 scopus 로고
    • Accuracy and verification of load-pull measurements, St. Regis Dollard-des-Ormeaux, Quebec, Canada
    • Focus Microwaves Inc, September
    • Focus Microwaves Inc., "Accuracy and verification of load-pull measurements," St. Regis Dollard-des-Ormeaux, Quebec, Canada, Application Note n. 18, September 1994.
    • (1994) Application Note , Issue.18
  • 8
    • 0027585391 scopus 로고
    • An improved calibration technique for on-wafer large-signal transistor characterization
    • Apr
    • A. Ferrero and U. Pisani, "An improved calibration technique for on-wafer large-signal transistor characterization," IEEE Trans. Instrum. Meas., vol. 47, pp. 360-364, Apr. 1993.
    • (1993) IEEE Trans. Instrum. Meas , vol.47 , pp. 360-364
    • Ferrero, A.1    Pisani, U.2
  • 9
    • 0034818003 scopus 로고    scopus 로고
    • Accuracy evaluation of on-wafer load-pull measurements
    • Jan
    • A. Ferrero, V. Teppati, and A. Carullo, "Accuracy evaluation of on-wafer load-pull measurements," IEEE Trans. Microwave Theory Tech. vol. 49, (no. 1), pp. 39-43, Jan. 2001.
    • (2001) IEEE Trans. Microwave Theory Tech , vol.49 , Issue.1 , pp. 39-43
    • Ferrero, A.1    Teppati, V.2    Carullo, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.