메뉴 건너뛰기




Volumn 38, Issue 8, 2007, Pages 2254-2256

Diagnosis of right-to-left shunt with transcranial Doppler and vertebrobasilar recording

Author keywords

Middle cerebral artery; Patent foramen ovale; Right to left shunt; Stroke; Temporal bone window; Transcranial Doppler; Vertebrobasilar circulation

Indexed keywords

ADULT; ARTICLE; CONTROLLED STUDY; DOPPLER ECHOGRAPHY; HEART RIGHT LEFT SHUNT; HUMAN; MAJOR CLINICAL STUDY; MIDDLE CEREBRAL ARTERY; PRIORITY JOURNAL; SENSITIVITY AND SPECIFICITY; VALSALVA MANEUVER; VERTEBRAL ARTERY; BASILAR ARTERY; BRAIN CIRCULATION; CEREBRAL ARTERY DISEASE; COMPARATIVE STUDY; ECHOGRAPHY; EVALUATION; HEART SEPTUM DEFECT; HISTOLOGY; METHODOLOGY; MIDDLE AGED; OCCIPITAL BONE; PATHOPHYSIOLOGY; PREDICTION AND FORECASTING; TEMPORAL BONE; VERTEBROBASILAR INSUFFICIENCY;

EID: 34548266583     PISSN: 00392499     EISSN: None     Source Type: Journal    
DOI: 10.1161/STROKEAHA.106.479485     Document Type: Article
Times cited : (43)

References (23)
  • 3
    • 0026639871 scopus 로고    scopus 로고
    • Di Tullio M, Sacco RL, Gopal A, Mohr JP, Homma S. Patent foramen ovale as a risk factor for cryptogenic stroke. Ann Intern Med. 1992;117:461-465
    • Di Tullio M, Sacco RL, Gopal A, Mohr JP, Homma S. Patent foramen ovale as a risk factor for cryptogenic stroke. Ann Intern Med. 1992;117:461-465.
  • 4
    • 0027371189 scopus 로고
    • Atrial septal aneurysm and patent foramen ovale as risk factors for cryptogenic stroke in patients less than 55 years of age: A study using transesophageal echocardiography
    • Cabanes L, Mas JL, Cohen A, Amarenco P, Cabanes PA, Oubary P, Chedru F, Guérin F, Bousser MG, de Recondo J. Atrial septal aneurysm and patent foramen ovale as risk factors for cryptogenic stroke in patients less than 55 years of age: a study using transesophageal echocardiography. Stroke. 1993;24:1865-1873.
    • (1993) Stroke , vol.24 , pp. 1865-1873
    • Cabanes, L.1    Mas, J.L.2    Cohen, A.3    Amarenco, P.4    Cabanes, P.A.5    Oubary, P.6    Chedru, F.7    Guérin, F.8    Bousser, M.G.9    de Recondo, J.10
  • 5
  • 6
    • 0028059955 scopus 로고
    • Transesophageal echocardiography and contrast-TCD in the detection of a patent foramen ovale: Experiences with 111 patients
    • Klotzsch C, Janssen G, Berlit P. Transesophageal echocardiography and contrast-TCD in the detection of a patent foramen ovale: experiences with 111 patients. Neurology. 1994;44:1603-1606.
    • (1994) Neurology , vol.44 , pp. 1603-1606
    • Klotzsch, C.1    Janssen, G.2    Berlit, P.3
  • 8
    • 0033549030 scopus 로고    scopus 로고
    • Potential source of cerebral embolism in migraine with aura: A transcranial Doppler study
    • Anzola GP, Magoni M, Guindani M, Rozzini L, Dalla Volta G. Potential source of cerebral embolism in migraine with aura: a transcranial Doppler study. Neurology. 1999;52:1622-1625.
    • (1999) Neurology , vol.52 , pp. 1622-1625
    • Anzola, G.P.1    Magoni, M.2    Guindani, M.3    Rozzini, L.4    Dalla Volta, G.5
  • 9
    • 5344248659 scopus 로고    scopus 로고
    • Cluster headache and right-to-left shunt on contrast transcranial Doppler: A case-control study
    • Finocchi C, Del Sette M, Angeli S, Rizzi D, Gandolfo C. Cluster headache and right-to-left shunt on contrast transcranial Doppler: a case-control study. Neurology. 2004;63:1309-1310.
    • (2004) Neurology , vol.63 , pp. 1309-1310
    • Finocchi, C.1    Del Sette, M.2    Angeli, S.3    Rizzi, D.4    Gandolfo, C.5
  • 11
    • 0031963545 scopus 로고    scopus 로고
    • Prevalence of patent foramen ovale and its contribution to hypoxemia in patients with obstructive sleep apnea
    • Shanoudy H, Soliman A, Raggi P, Liu JW, Russell DC, Jarmukli NF. Prevalence of patent foramen ovale and its contribution to hypoxemia in patients with obstructive sleep apnea. Chest. 1998;113:91-96.
    • (1998) Chest , vol.113 , pp. 91-96
    • Shanoudy, H.1    Soliman, A.2    Raggi, P.3    Liu, J.W.4    Russell, D.C.5    Jarmukli, N.F.6
  • 12
    • 0038338404 scopus 로고    scopus 로고
    • Prevalence of patent foramen ovale in subjects with obstructive sleep apnea: A transcranial Doppler ultrasound study
    • Beelke M, Angeli S, Del Sette M, Gandolfo C, Cabano ME, Canovaro P, Nobili L, Ferrillo F. Prevalence of patent foramen ovale in subjects with obstructive sleep apnea: a transcranial Doppler ultrasound study. Sleep Med. 2003;4:219-223.
    • (2003) Sleep Med , vol.4 , pp. 219-223
    • Beelke, M.1    Angeli, S.2    Del Sette, M.3    Gandolfo, C.4    Cabano, M.E.5    Canovaro, P.6    Nobili, L.7    Ferrillo, F.8
  • 13
    • 0024388819 scopus 로고
    • Relation between interatrial shunts and decompression sickness in divers
    • Wilmshurst PT, Byrne JC, Webb-Peploe MM. Relation between interatrial shunts and decompression sickness in divers. Lancet. 1989;2:1302-1306.
    • (1989) Lancet , vol.2 , pp. 1302-1306
    • Wilmshurst, P.T.1    Byrne, J.C.2    Webb-Peploe, M.M.3
  • 15
    • 0030481612 scopus 로고    scopus 로고
    • Patent foramen ovale and transcranial Doppler: comparison of different procedures. Stroke. 1996;27:2251-2255
    • Zanette EM, Mancini G, De Castro S, Solaro M, Cartoni D, Chiarotti F. Patent foramen ovale and transcranial Doppler: comparison of different procedures. Stroke. 1996;27:2251-2255.
    • Zanette, E.M.1    Mancini, G.2    De Castro, S.3    Solaro, M.4    Cartoni, D.5    Chiarotti, F.6
  • 16
    • 0032899810 scopus 로고    scopus 로고
    • Contrast transcranial Doppler ultrasound in the detection of right-to-left shunt: Reproducibility, comparison of two agents, and distribution of microemboli
    • Droste DW, Reisener M, Kemeny V, Dittrich R, Shulte-Altedorneburg G, Stypman J, Widimsky P, Wichter T, Ringelstein EB. Contrast transcranial Doppler ultrasound in the detection of right-to-left shunt: reproducibility, comparison of two agents, and distribution of microemboli. Stroke. 1999;30:1014-1018.
    • (1999) Stroke , vol.30 , pp. 1014-1018
    • Droste, D.W.1    Reisener, M.2    Kemeny, V.3    Dittrich, R.4    Shulte-Altedorneburg, G.5    Stypman, J.6    Widimsky, P.7    Wichter, T.8    Ringelstein, E.B.9
  • 17
    • 0033773515 scopus 로고    scopus 로고
    • Detection of right-to-left shunt with ultrasound contrast agent and transcranial Doppler sonography
    • Jauss M, Zanette E. Detection of right-to-left shunt with ultrasound contrast agent and transcranial Doppler sonography. Cerebrovasc Dis. 2000;10:490-496.
    • (2000) Cerebrovasc Dis , vol.10 , pp. 490-496
    • Jauss, M.1    Zanette, E.2
  • 18
    • 0036129532 scopus 로고    scopus 로고
    • Transcranial Doppler in the diagnosis of cardiac patent foramen ovale
    • Angeli S, Del Sette M, Beelke M, Anzola GP, Zanette E. Transcranial Doppler in the diagnosis of cardiac patent foramen ovale. Neurol Sci. 2001;22:353-356.
    • (2001) Neurol Sci , vol.22 , pp. 353-356
    • Angeli, S.1    Del Sette, M.2    Beelke, M.3    Anzola, G.P.4    Zanette, E.5
  • 19
    • 0031861858 scopus 로고    scopus 로고
    • The need to quantify right-to-left shunt in acute ischemic stroke: A case-control study
    • Serena J, Segura T, Perez-Ayuso MJ, Bassaganyas J, Molins A, Davalos A. The need to quantify right-to-left shunt in acute ischemic stroke: a case-control study. Stroke. 1998;29:1322-1328.
    • (1998) Stroke , vol.29 , pp. 1322-1328
    • Serena, J.1    Segura, T.2    Perez-Ayuso, M.J.3    Bassaganyas, J.4    Molins, A.5    Davalos, A.6
  • 20
    • 0742271307 scopus 로고    scopus 로고
    • Image quality of the temporal bone window examined by transcranial Doppler sonography and correlation with postmortem computed tomography measurements
    • Kollar J, Schulte-Altedorneburg G, Sikula J, Fulesdi B, Ringelstein EB, Mehta V, Csiba L, Droste DW. Image quality of the temporal bone window examined by transcranial Doppler sonography and correlation with postmortem computed tomography measurements. Cerebrovasc Dis. 2004;17:61-65.
    • (2004) Cerebrovasc Dis , vol.17 , pp. 61-65
    • Kollar, J.1    Schulte-Altedorneburg, G.2    Sikula, J.3    Fulesdi, B.4    Ringelstein, E.B.5    Mehta, V.6    Csiba, L.7    Droste, D.W.8
  • 21
    • 0028203282 scopus 로고
    • The effect of velocity on the appearance of embolic signals studied in transcranial Doppler models
    • May;
    • Droste DW, Markus HS, Nassiri D, Brown MM. The effect of velocity on the appearance of embolic signals studied in transcranial Doppler models. Stroke. 1994 May;25:986-991.
    • (1994) Stroke , vol.25 , pp. 986-991
    • Droste, D.W.1    Markus, H.S.2    Nassiri, D.3    Brown, M.M.4
  • 22
    • 30344432442 scopus 로고    scopus 로고
    • Meissner I, Khandheria BK, Heit JA, Petty GW, Sheps SG, Schwartz GL, Whisnant JP, Wiebers DO, Covalt JL, Petterson TM, Christianson TJ, Agmon Y. Patent foramen ovale: innocent or guilty? evidence from a prospective population-based study. J Am Coll Cardiol. 2006;47:440-445
    • Meissner I, Khandheria BK, Heit JA, Petty GW, Sheps SG, Schwartz GL, Whisnant JP, Wiebers DO, Covalt JL, Petterson TM, Christianson TJ, Agmon Y. Patent foramen ovale: innocent or guilty? evidence from a prospective population-based study. J Am Coll Cardiol. 2006;47:440-445.
  • 23
    • 33645859339 scopus 로고    scopus 로고
    • Different degrees of right-to-left shunting predict migraine and stroke: Data from 420 patients
    • Anzola GP, Morandi E, Casilli F, Onorato E. Different degrees of right-to-left shunting predict migraine and stroke: data from 420 patients. Neurology. 2006;66:765-767.
    • (2006) Neurology , vol.66 , pp. 765-767
    • Anzola, G.P.1    Morandi, E.2    Casilli, F.3    Onorato, E.4