메뉴 건너뛰기




Volumn 7, Issue 2, 2006, Pages 38-49

PTV margin for dose escalated radiation therapy of prostate cancer with daily on-line realignment using internal fiducial markers: Monte Carlo approach and dose population histogram (DPH) analysis

Author keywords

Biological factors; Dose population histogram; Organ motion simulation; Patient realignment; Prostate cancer dose escalation

Indexed keywords

ARTICLE; COMPUTER SIMULATION; EVALUATION; HUMAN; MALE; MONTE CARLO METHOD; PATHOLOGY; PROSTATE TUMOR; RADIATION DOSE; RADIATION RESPONSE;

EID: 34548242211     PISSN: None     EISSN: 15269914     Source Type: Journal    
DOI: 10.1120/jacmp.v7i2.2210     Document Type: Article
Times cited : (9)

References (28)
  • 1
    • 10744230014 scopus 로고    scopus 로고
    • Impact of neoadjuvant androgen ablation and other factors on late toxicity after external beam prostate radiotherapy
    • Liu M, Pickles T, Agranovich A, et al. Impact of neoadjuvant androgen ablation and other factors on late toxicity after external beam prostate radiotherapy. Int J Radiat Oncol Biol Phys. 2004;58:59-67.
    • (2004) Int J Radiat Oncol Biol Phys , vol.58 , pp. 59-67
    • Liu, M.1    Pickles, T.2    Agranovich, A.3
  • 3
    • 0030936848 scopus 로고    scopus 로고
    • Optimization of conformal radiation treatment of prostate cancer: Report of a dose escalation study
    • Hanks GE, Schultheiss TE, Hanlon AL, et al. Optimization of conformal radiation treatment of prostate cancer: Report of a dose escalation study. Int J Radiat Oncol Biol Phys. 1997;37:543-550.
    • (1997) Int J Radiat Oncol Biol Phys , vol.37 , pp. 543-550
    • Hanks, G.E.1    Schultheiss, T.E.2    Hanlon, A.L.3
  • 4
    • 0032054090 scopus 로고    scopus 로고
    • Estimation of the incidence of late bladder and rectum complications after high-dose (70-78 Gy) conformal radiotherapy for prostate cancer, using dose-volume histograms
    • Boersma LJ, van den Brink M, Bruce AM. Estimation of the incidence of late bladder and rectum complications after high-dose (70-78 Gy) conformal radiotherapy for prostate cancer, using dose-volume histograms. Int J Radiat Oncol Biol Phys. 1998;41:83-92.
    • (1998) Int J Radiat Oncol Biol Phys , vol.41 , pp. 83-92
    • Boersma, L.J.1    van den Brink, M.2    Bruce, A.M.3
  • 5
    • 0028882448 scopus 로고
    • Three dimensional conformal radiotherapy for the treatment of prostate cancer: Low risk of chronic rectal morbidity observed in a large series of patients
    • Sandler HM, McLaughlin PW, Ten haken RK. Three dimensional conformal radiotherapy for the treatment of prostate cancer: Low risk of chronic rectal morbidity observed in a large series of patients. Int J Radiat Oncol Biol Phys. 1995;33:797-801.
    • (1995) Int J Radiat Oncol Biol Phys , vol.33 , pp. 797-801
    • Sandler, H.M.1    McLaughlin, P.W.2    Ten haken, R.K.3
  • 6
    • 0031779250 scopus 로고    scopus 로고
    • Dose escalation with three-dimensional conformal radiation therapy affects the outcome in prostate cancer
    • Zelefsky MJ, Leibel SA, Gaudin PB. Dose escalation with three-dimensional conformal radiation therapy affects the outcome in prostate cancer. Int J Radiat Oncol Biol Phys. 1998;41:491-500.
    • (1998) Int J Radiat Oncol Biol Phys , vol.41 , pp. 491-500
    • Zelefsky, M.J.1    Leibel, S.A.2    Gaudin, P.B.3
  • 7
    • 0034237797 scopus 로고    scopus 로고
    • The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy
    • van Herk M, Remeijer P, Rasch C, Lebesque JV. The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy. Int J Radiat Oncol Biol Phys. 2000;47:1121-1135.
    • (2000) Int J Radiat Oncol Biol Phys , vol.47 , pp. 1121-1135
    • van Herk, M.1    Remeijer, P.2    Rasch, C.3    Lebesque, J.V.4
  • 8
    • 4444285372 scopus 로고    scopus 로고
    • On-line aSi portal imaging of implanted fiducial markers for the reduction of interfraction error during conformal radiotherapy of prostate carcinoma
    • Chung PW, Haycocks T, Brown T, et al. On-line aSi portal imaging of implanted fiducial markers for the reduction of interfraction error during conformal radiotherapy of prostate carcinoma. Int J Radiat Oncol Biol Phys. 2004;60:329-334.
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , pp. 329-334
    • Chung, P.W.1    Haycocks, T.2    Brown, T.3
  • 9
    • 32544444126 scopus 로고    scopus 로고
    • Internal fiducial markers can assist dose escalation in treatment of prostate cancer: Result of organ motion simulations
    • Zhang M, Moiseenko VM, Liu M, Craig T. Internal fiducial markers can assist dose escalation in treatment of prostate cancer: Result of organ motion simulations. Phys Med Biol. 2006;51:269-285.
    • (2006) Phys Med Biol , vol.51 , pp. 269-285
    • Zhang, M.1    Moiseenko, V.M.2    Liu, M.3    Craig, T.4
  • 10
    • 1842528895 scopus 로고    scopus 로고
    • Characterization of rectal normal tissue complication probability after high-dose external beam radiotherapy for prostate cancer
    • Cheung R, Tucker SL, Ye JS, et al. Characterization of rectal normal tissue complication probability after high-dose external beam radiotherapy for prostate cancer. Int J Radiat Oncol Biol Phys. 2004;58:1513-1519.
    • (2004) Int J Radiat Oncol Biol Phys , vol.58 , pp. 1513-1519
    • Cheung, R.1    Tucker, S.L.2    Ye, J.S.3
  • 11
    • 4644296750 scopus 로고    scopus 로고
    • Fitting late rectal bleeding data using different NTCP models: Results from an Italian multi-centric study (AIROPROS0101)
    • Rancati T, Fiorino C, Gagliardi G, et al. Fitting late rectal bleeding data using different NTCP models: Results from an Italian multi-centric study (AIROPROS0101). Radiother Oncol. 2004;73:21-32.
    • (2004) Radiother Oncol , vol.73 , pp. 21-32
    • Rancati, T.1    Fiorino, C.2    Gagliardi, G.3
  • 12
    • 0025939587 scopus 로고
    • Tolerance of normal tissue to therapeutic irradiation
    • Emami B, Lyman J, Brown A, et al. Tolerance of normal tissue to therapeutic irradiation. Int J Radiat Oncol Biol Phys. 1991;21:109-122.
    • (1991) Int J Radiat Oncol Biol Phys , vol.21 , pp. 109-122
    • Emami, B.1    Lyman, J.2    Brown, A.3
  • 14
    • 0037572347 scopus 로고    scopus 로고
    • CERR: A computational environment for radiotherapy research
    • Deasy JO, Blanco AI, Clark VH. CERR: A computational environment for radiotherapy research. Med Phys. 2003;30:979-985.
    • (2003) Med Phys , vol.30 , pp. 979-985
    • Deasy, J.O.1    Blanco, A.I.2    Clark, V.H.3
  • 15
    • 0042890340 scopus 로고    scopus 로고
    • Limitations of a convolution method for modeling geometric uncertainties in radiation therapy. I. The effect of shift invariance
    • Craig T, Battista J, Van Dyk J. Limitations of a convolution method for modeling geometric uncertainties in radiation therapy. I. The effect of shift invariance. Med Phys. 2003;30:2001-2011.
    • (2003) Med Phys , vol.30 , pp. 2001-2011
    • Craig, T.1    Battista, J.2    Van Dyk, J.3
  • 16
    • 0041888229 scopus 로고    scopus 로고
    • Limitations of a convolution method for modeling geometric uncertainties in radiation therapy. II. The effect of a finite number of fractions
    • Craig T, Battista J, Van Dyk J. Limitations of a convolution method for modeling geometric uncertainties in radiation therapy. II. The effect of a finite number of fractions. Med Phys. 2003;30:2012-2020.
    • (2003) Med Phys , vol.30 , pp. 2012-2020
    • Craig, T.1    Battista, J.2    Van Dyk, J.3
  • 20
    • 0024317128 scopus 로고
    • Calculation of complication probability factors for non-uniform normal tissue irradiation: The effective volume method
    • Kutcher GJ, Burman C. Calculation of complication probability factors for non-uniform normal tissue irradiation: The effective volume method. Int J Radiat Oncol Biol Phys. 1989; 16:1623-1630.
    • (1989) Int J Radiat Oncol Biol Phys , vol.16 , pp. 1623-1630
    • Kutcher, G.J.1    Burman, C.2
  • 21
    • 0024339650 scopus 로고    scopus 로고
    • Lyman JT, Wolbarst AB. Optimization of radiation therapy, IV: A dose-histogram reduction algorithm. Int J Radiat Oncol Biol Phys. 1989;17:433-436.
    • Lyman JT, Wolbarst AB. Optimization of radiation therapy, IV: A dose-volume histogram reduction algorithm. Int J Radiat Oncol Biol Phys. 1989;17:433-436.
  • 22
    • 85024970432 scopus 로고    scopus 로고
    • Stereotactic IMRT for prostate cancer: Setup accuracy of a new stereotactic body localization system
    • Wang L, Jacob R, Chen L, et al. Stereotactic IMRT for prostate cancer: Setup accuracy of a new stereotactic body localization system. J Appl Clin Med Phys. 2004;5:18-28.
    • (2004) J Appl Clin Med Phys , vol.5 , pp. 18-28
    • Wang, L.1    Jacob, R.2    Chen, L.3
  • 23
    • 14844286440 scopus 로고    scopus 로고
    • Dose-response characteristics of low- and intermediate-risk prostate cancer treated with external beam radiotherapy
    • Cheung R, Tucker S, Lee AK, et al. Dose-response characteristics of low- and intermediate-risk prostate cancer treated with external beam radiotherapy. Int J Radiat Oncol Biol Phys. 2005;61:993-1002.
    • (2005) Int J Radiat Oncol Biol Phys , vol.61 , pp. 993-1002
    • Cheung, R.1    Tucker, S.2    Lee, A.K.3
  • 24
    • 0036835238 scopus 로고    scopus 로고
    • The use of rectal balloon during the delivery of intensity modulated radiotherapy (IMRT) for prostate cancer: More than just a prostate gland immobilization device?
    • Teh BS, McGary JE, Dong L, et al. The use of rectal balloon during the delivery of intensity modulated radiotherapy (IMRT) for prostate cancer: More than just a prostate gland immobilization device? Cancer J. 2002;8:476-483.
    • (2002) Cancer J , vol.8 , pp. 476-483
    • Teh, B.S.1    McGary, J.E.2    Dong, L.3
  • 25
    • 15744370683 scopus 로고    scopus 로고
    • Evaluation of inter and intrafraction organ motion during intensity modulated radiation therapy (IMRT) for localized prostate cancer measured by a newly developed on-board image-guided system
    • Britton KR, Takai Y, Mitsuya M, Nemoto K, Ogawa Y, Yamada S. Evaluation of inter and intrafraction organ motion during intensity modulated radiation therapy (IMRT) for localized prostate cancer measured by a newly developed on-board image-guided system. Radiat Med. 2005;23:14-24.
    • (2005) Radiat Med , vol.23 , pp. 14-24
    • Britton, K.R.1    Takai, Y.2    Mitsuya, M.3    Nemoto, K.4    Ogawa, Y.5    Yamada, S.6
  • 26
    • 0038503664 scopus 로고    scopus 로고
    • Use of portal images and BAT ultrasonography to measure setup error and organ motion for prostate IMRT: Implications for treatment margins
    • Little DJ, Dong L, Levy LB, Chandra A, Kuban DA. Use of portal images and BAT ultrasonography to measure setup error and organ motion for prostate IMRT: Implications for treatment margins. Int J Radiat Oncol Biol Phys. 2003;56:1218-1224.
    • (2003) Int J Radiat Oncol Biol Phys , vol.56 , pp. 1218-1224
    • Little, D.J.1    Dong, L.2    Levy, L.B.3    Chandra, A.4    Kuban, D.A.5
  • 27
    • 0034176902 scopus 로고    scopus 로고
    • Late rectal toxicity after conformal radiotherapy of prostate cancer (I): Multivariate analysis and dose-response
    • Skwarchuk MW, Jackson A, Zelefsky MJ, et al. Late rectal toxicity after conformal radiotherapy of prostate cancer (I): Multivariate analysis and dose-response. Int J Radiat Oncol Biol Phys. 2000;47:103-113.
    • (2000) Int J Radiat Oncol Biol Phys , vol.47 , pp. 103-113
    • Skwarchuk, M.W.1    Jackson, A.2    Zelefsky, M.J.3
  • 28
    • 0034307033 scopus 로고    scopus 로고
    • Complications from radiotherapy dose escalation in prostate cancer: Preliminary results of a randomized trial
    • Storey MR, Pollack A, Zagars G, Smith L, Antolak J, Rosen I. Complications from radiotherapy dose escalation in prostate cancer: Preliminary results of a randomized trial. Int J Radiat Oncol Biol Phys. 2000;48:635-642.
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , pp. 635-642
    • Storey, M.R.1    Pollack, A.2    Zagars, G.3    Smith, L.4    Antolak, J.5    Rosen, I.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.