메뉴 건너뛰기




Volumn 6498, Issue , 2007, Pages

High-resolution image reconstruction for PET using estimated detector response functions

Author keywords

Detector response; Iterative image reconstruction; Positron emission tomography; System modeling

Indexed keywords

ITERATIVE METHODS; MATHEMATICAL MODELS; MONTE CARLO METHODS; POSITRON EMISSION TOMOGRAPHY; STATISTICS; TWO DIMENSIONAL;

EID: 34548233230     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.716739     Document Type: Conference Paper
Times cited : (2)

References (8)
  • 1
    • 0031981253 scopus 로고    scopus 로고
    • High-resolution 3-D Bayesian image reconstruction using the microPET small-animal scanner
    • J. Qi, R. Leahy, S. Cherry, A. Chatziioannou, and T. Farquhar, "High-resolution 3-D Bayesian image reconstruction using the microPET small-animal scanner," Phys. Med. Biol., vol. 43, pp. 1001-1013, 1998.
    • (1998) Phys. Med. Biol , vol.43 , pp. 1001-1013
    • Qi, J.1    Leahy, R.2    Cherry, S.3    Chatziioannou, A.4    Farquhar, T.5
  • 2
    • 33746216301 scopus 로고    scopus 로고
    • Modeling and incorporating of system response functions in 3-D whole body PET
    • A.M. Alessio, P.E. Kihahan, and T.K. Lewellen, "Modeling and incorporating of system response functions in 3-D whole body PET," IEEE Trans. Med. Imaging, Vol. 25, pp. 828-837, 2006.
    • (2006) IEEE Trans. Med. Imaging , vol.25 , pp. 828-837
    • Alessio, A.M.1    Kihahan, P.E.2    Lewellen, T.K.3
  • 3
    • 0038736677 scopus 로고    scopus 로고
    • Quantitative comparison of FBP, EM, and Bayesian reconstruction algorithm for the IndyPET scanner
    • T. Frese, N.N. Rouze, C. A. Bouman, K. Sauer, and G. D. Hutchins, "Quantitative comparison of FBP, EM, and Bayesian reconstruction algorithm for the IndyPET scanner," IEEE Trans Med Imaging, vol. 22, pp. 258-76, 2003.
    • (2003) IEEE Trans Med Imaging , vol.22 , pp. 258-276
    • Frese, T.1    Rouze, N.N.2    Bouman, C.A.3    Sauer, K.4    Hutchins, G.D.5
  • 4
    • 0034205094 scopus 로고    scopus 로고
    • Detector response models for statistical iterative image reconstruction in high resolution PET
    • June
    • V. Selivanov, Y. Picard, J. Cadorette, S. Rodrigue, and R. Lecomte, "Detector response models for statistical iterative image reconstruction in high resolution PET," IEEE Trans Nuclear Science, vol.47, pp. 1168-1175, June 2000.
    • (2000) IEEE Trans Nuclear Science , vol.47 , pp. 1168-1175
    • Selivanov, V.1    Picard, Y.2    Cadorette, J.3    Rodrigue, S.4    Lecomte, R.5
  • 5
    • 33746191812 scopus 로고    scopus 로고
    • Fully 3-D PET reconstruction with system matrix derived from point source measurements
    • V. Y. Panin, H. Rothfuss, D. Hu, C. Michel, and M. E. Casey, "Fully 3-D PET reconstruction with system matrix derived from point source measurements," IEEE Trans. Med. Imaging, vol. 25, pp. 907-921, 2006.
    • (2006) IEEE Trans. Med. Imaging , vol.25 , pp. 907-921
    • Panin, V.Y.1    Rothfuss, H.2    Hu, D.3    Michel, C.4    Casey, M.E.5
  • 6
    • 0030362530 scopus 로고    scopus 로고
    • Accurate geometric and physical response modeling for statistical image reconstruction in high resolution PET
    • Anaheim, CA
    • E. Mumcuoglu, R. Leahy, S. Cherry, and E. Hoffman, "Accurate geometric and physical response modeling for statistical image reconstruction in high resolution PET," IEEE Nuclear Science Symposium Conference Record, Anaheim, CA, 1996, pp. 1569-1573.
    • (1996) IEEE Nuclear Science Symposium Conference Record , pp. 1569-1573
    • Mumcuoglu, E.1    Leahy, R.2    Cherry, S.3    Hoffman, E.4