메뉴 건너뛰기




Volumn 36, Issue 11, 2007, Pages 1581-1604

On the performance of SCF in seismic isolation of the interior equipment of buildings

Author keywords

Equipment response; Isolated raised floor; Primary structure; SCF; Secondary system

Indexed keywords

DEGREES OF FREEDOM (MECHANICS); EARTHQUAKE EFFECTS; EQUATIONS OF MOTION; HARMONIC ANALYSIS; NUMERICAL ANALYSIS; SEISMIC RESPONSE;

EID: 34548210329     PISSN: 00988847     EISSN: 10969845     Source Type: Journal    
DOI: 10.1002/eqe.708     Document Type: Article
Times cited : (38)

References (18)
  • 1
    • 34548286255 scopus 로고    scopus 로고
    • Recent progress towards the seismic control of structural and non-structural systems in hospitals
    • Gaithersburg, MD, Multidisciplinary Centre for Earthquake Engineering Research MCEER, State University of New York at Buffalo, Buffalo, 17-22 May
    • Filiatrault A, Lee G, Aref A, Bruneau M, Constantinou M, Reinhom A, Whittaker A. Recent progress towards the seismic control of structural and non-structural systems in hospitals. 36th Technical Meeting on Panel on Wind and Seismic Effects, Gaithersburg, MD, Multidisciplinary Centre for Earthquake Engineering Research (MCEER), State University of New York at Buffalo, Buffalo, 17-22 May 2004.
    • (2004) 36th Technical Meeting on Panel on Wind and Seismic Effects
    • Filiatrault, A.1    Lee, G.2    Aref, A.3    Bruneau, M.4    Constantinou, M.5    Reinhom, A.6    Whittaker, A.7
  • 2
    • 85009311626 scopus 로고    scopus 로고
    • Hall JF (ed.). Northridge Earthquake of January 17, 1994, Reconnaissance Report, 1. Earthquake Spectra 1995; 11(Suppl. C):Publication 95-03:523.
    • Hall JF (ed.). Northridge Earthquake of January 17, 1994, Reconnaissance Report, vol. 1. Earthquake Spectra 1995; 11(Suppl. C):Publication 95-03:523.
  • 5
    • 0018519867 scopus 로고
    • Performance of a 230 KV ATB 7 power circuit breaker mounted on GAPEC seismic isolators
    • Department of Civil Engineering, Stanford University
    • Kircher CA. Performance of a 230 KV ATB 7 power circuit breaker mounted on GAPEC seismic isolators. JABEEC No. 40, Department of Civil Engineering, Stanford University, 1979.
    • (1979) JABEEC No. 40
    • Kircher, C.A.1
  • 6
    • 0011248148 scopus 로고
    • Isolating building contents from earthquake induced floor motions
    • EERI
    • Yaghoubian J. Isolating building contents from earthquake induced floor motions. Earthquake Spectra (EERI) 1991; 7(1):130.
    • (1991) Earthquake Spectra , vol.7 , Issue.1 , pp. 130
    • Yaghoubian, J.1
  • 7
    • 34548227233 scopus 로고
    • Seismic base isolation of gas insulated electrical substations: Design, experimental and numerical activities, evaluation of the applicability
    • Vienna, Austria
    • Bonacina G. Seismic base isolation of gas insulated electrical substations: design, experimental and numerical activities, evaluation of the applicability, 10th European Conference on Earthquake Engineering, Vienna, Austria, 1994.
    • (1994) 10th European Conference on Earthquake Engineering
    • Bonacina, G.1
  • 8
    • 24544473498 scopus 로고
    • Study of seismic isolation systems for computer floors
    • Technical Report NCEER-94-0020, July
    • Lambrou V, Constantinou MC. Study of seismic isolation systems for computer floors. Technical Report NCEER-94-0020, July, 1994.
    • (1994)
    • Lambrou, V.1    Constantinou, M.C.2
  • 15
    • 0025382923 scopus 로고    scopus 로고
    • Constantinou M, Mokha A, Reinhorn A. Teflon bearings in base isolation, II: Modeling. Journal of Structural Engineering (ASCE) 1990; 116:455-474.
    • Constantinou M, Mokha A, Reinhorn A. Teflon bearings in base isolation, II: Modeling. Journal of Structural Engineering (ASCE) 1990; 116:455-474.
  • 16
    • 0034746390 scopus 로고    scopus 로고
    • Numerical modeling of MDOF structures with sliding supports using rigid-plastic link
    • Vafai A, Hamidi M, Ahmadi G. Numerical modeling of MDOF structures with sliding supports using rigid-plastic link. Earthquake Engineering and Structural Dynamics 2001; 30:27-42.
    • (2001) Earthquake Engineering and Structural Dynamics , vol.30 , pp. 27-42
    • Vafai, A.1    Hamidi, M.2    Ahmadi, G.3
  • 17
    • 0034396305 scopus 로고    scopus 로고
    • A simple method for analysis of sliding structures considering variations of friction coefficient
    • Vafai A, Hamidi M, Ahmadi G. A simple method for analysis of sliding structures considering variations of friction coefficient. Journal of Earthquake Engineering 2000; 4:233-250.
    • (2000) Journal of Earthquake Engineering , vol.4 , pp. 233-250
    • Vafai, A.1    Hamidi, M.2    Ahmadi, G.3
  • 18
    • 34548284293 scopus 로고    scopus 로고
    • Sliding concave foundation (SCF) isolation system
    • submitted in partial fulfillment of the requirement for the degree of Doctor of Philosophy, The University of Western Ontario, London, Canada
    • Hamidi M. Sliding concave foundation (SCF) isolation system. Thesis, submitted in partial fulfillment of the requirement for the degree of Doctor of Philosophy, The University of Western Ontario, London, Canada, 2006.
    • (2006) Thesis
    • Hamidi, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.