메뉴 건너뛰기




Volumn 25, Issue 2, 2007, Pages 261-265

Real-time Three-Dimensional Echocardiography in Stress Testing: Bi- and Triplane Imaging for Enhanced Image Acquisition

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; EXERCISE TEST; HEART LEFT VENTRICLE WALL; HEART MOVEMENT; IMAGE ANALYSIS; INTERMETHOD COMPARISON; PRIORITY JOURNAL; REVIEW; THREE DIMENSIONAL ECHOCARDIOGRAPHY; TRANSDUCER;

EID: 34548161566     PISSN: 07338651     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ccl.2007.05.007     Document Type: Review
Times cited : (6)

References (10)
  • 1
    • 0030060589 scopus 로고    scopus 로고
    • Analysis of interinstitutional observer agreement in interpretation of dobutamine stress echocardiograms
    • Hoffmann R., Lethen H., Marwick T., et al. Analysis of interinstitutional observer agreement in interpretation of dobutamine stress echocardiograms. J Am Coll Cardiol 27 (1996) 330-336
    • (1996) J Am Coll Cardiol , vol.27 , pp. 330-336
    • Hoffmann, R.1    Lethen, H.2    Marwick, T.3
  • 2
    • 0032948742 scopus 로고    scopus 로고
    • Assessment of regional wall motion abnormalities with real-time 3-dimensional echocardiography
    • Collins M., Hsieh A., Ohazama C.J., et al. Assessment of regional wall motion abnormalities with real-time 3-dimensional echocardiography. J Am Soc Echocardiogr 12 (1999) 7-14
    • (1999) J Am Soc Echocardiogr , vol.12 , pp. 7-14
    • Collins, M.1    Hsieh, A.2    Ohazama, C.J.3
  • 3
    • 0035312558 scopus 로고    scopus 로고
    • Real-time three-dimensional dobutamine stress echocardiography in assessment stress echocardiography in assessment of ischemia: comparison with two-dimensional dobutamine stress echocardiography
    • Ahmad M., Xie T., McCulloch M., et al. Real-time three-dimensional dobutamine stress echocardiography in assessment stress echocardiography in assessment of ischemia: comparison with two-dimensional dobutamine stress echocardiography. J Am Coll Cardiol 37 (2001) 1303-1309
    • (2001) J Am Coll Cardiol , vol.37 , pp. 1303-1309
    • Ahmad, M.1    Xie, T.2    McCulloch, M.3
  • 4
    • 0032957903 scopus 로고    scopus 로고
    • Feasibility of real-time 3-dimensional treadmill stress echocardiography
    • Zwas D.R., Takuma S., Mullis-Jansson S., et al. Feasibility of real-time 3-dimensional treadmill stress echocardiography. J Am Soc Echocardiogr 12 (1999) 285-289
    • (1999) J Am Soc Echocardiogr , vol.12 , pp. 285-289
    • Zwas, D.R.1    Takuma, S.2    Mullis-Jansson, S.3
  • 5
    • 0242467856 scopus 로고    scopus 로고
    • Biplane stress echocardiography using a prototype matrix array transducer
    • Sugeng L., Kirkpatrick J., Lang R.M., et al. Biplane stress echocardiography using a prototype matrix array transducer. J Am Soc Echocardiogr 16 (2003) 937-941
    • (2003) J Am Soc Echocardiogr , vol.16 , pp. 937-941
    • Sugeng, L.1    Kirkpatrick, J.2    Lang, R.M.3
  • 6
    • 33745766861 scopus 로고    scopus 로고
    • Comparison of real-time triplane and conventional 2D dobutamine stress echocardiography for the assessment of coronary artery disease
    • Eroglu E., D'hooge J., Herbots L., et al. Comparison of real-time triplane and conventional 2D dobutamine stress echocardiography for the assessment of coronary artery disease. Eur Heart J 27 (2006) 1719-1724
    • (2006) Eur Heart J , vol.27 , pp. 1719-1724
    • Eroglu, E.1    D'hooge, J.2    Herbots, L.3
  • 7
    • 25844477527 scopus 로고    scopus 로고
    • Noninvasive assessment of myocardial ischaemia using new real-time three-dimensional dobutamine stress echocardiography: comparison with conventional two-dimensional methods
    • Matsumura Y., Hozumi T., Arai K., et al. Noninvasive assessment of myocardial ischaemia using new real-time three-dimensional dobutamine stress echocardiography: comparison with conventional two-dimensional methods. Eur Heart J 26 (2005) 1625-1632
    • (2005) Eur Heart J , vol.26 , pp. 1625-1632
    • Matsumura, Y.1    Hozumi, T.2    Arai, K.3
  • 8
    • 33646109052 scopus 로고    scopus 로고
    • Feasibility of using a real-time 3-dimensional technique for contrast dobutamine stress echocardiography
    • Pulerwitz T., Hirata K., Abe Y., et al. Feasibility of using a real-time 3-dimensional technique for contrast dobutamine stress echocardiography. J Am Soc Echocardiogr 19 (2006) 540-545
    • (2006) J Am Soc Echocardiogr , vol.19 , pp. 540-545
    • Pulerwitz, T.1    Hirata, K.2    Abe, Y.3
  • 9
    • 33144459235 scopus 로고    scopus 로고
    • Comparison of contrast-enhanced real-time live 3-dimensional dobutamine stress echocardiography with contrast 2-dimensional echocardiography for detecting stress-induced wall-motion abnormalities
    • Takeuchi M., Otani S., Weinert L., et al. Comparison of contrast-enhanced real-time live 3-dimensional dobutamine stress echocardiography with contrast 2-dimensional echocardiography for detecting stress-induced wall-motion abnormalities. J Am Soc Echocardiogr 19 (2006) 294-299
    • (2006) J Am Soc Echocardiogr , vol.19 , pp. 294-299
    • Takeuchi, M.1    Otani, S.2    Weinert, L.3
  • 10
    • 33748087117 scopus 로고    scopus 로고
    • Role of biplane and biplane echocardiographically guided 3-dimensional echocardiography during dobutamine stress echocardiography
    • Yang H.S., Pellikka P.A., McCully R.B., et al. Role of biplane and biplane echocardiographically guided 3-dimensional echocardiography during dobutamine stress echocardiography. J Am Soc Echocardiogr 19 (2006) 1136-1143
    • (2006) J Am Soc Echocardiogr , vol.19 , pp. 1136-1143
    • Yang, H.S.1    Pellikka, P.A.2    McCully, R.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.