메뉴 건너뛰기




Volumn 62, Issue 3, 2007, Pages 348-352

Identification of bronchodilator responsiveness by forced oscillation admittance in children

Author keywords

[No Author keywords available]

Indexed keywords

BRONCHODILATING AGENT; SALBUTAMOL;

EID: 34548131617     PISSN: 00313998     EISSN: None     Source Type: Journal    
DOI: 10.1203/PDR.0b013e3180db2933     Document Type: Article
Times cited : (11)

References (25)
  • 1
    • 0346121617 scopus 로고    scopus 로고
    • The forced oscillation technique in clinical practice: Methodology, recommendations and future developments
    • Oostveen E, MacLeod D, Lorino H, Farre R, Hantos Z, Desager K, Marchal F 2003 The forced oscillation technique in clinical practice: methodology, recommendations and future developments. Eur Respir J 22:1026-1041
    • (2003) Eur Respir J , vol.22 , pp. 1026-1041
    • Oostveen, E.1    MacLeod, D.2    Lorino, H.3    Farre, R.4    Hantos, Z.5    Desager, K.6    Marchal, F.7
  • 3
    • 0021225598 scopus 로고
    • Upper airway walls impedance measured with head plethysmograph
    • Peslin R, Duvivier C, Jardin P 1984 Upper airway walls impedance measured with head plethysmograph. J Appl Physiol 57:596-600
    • (1984) J Appl Physiol , vol.57 , pp. 596-600
    • Peslin, R.1    Duvivier, C.2    Jardin, P.3
  • 4
    • 0026856510 scopus 로고
    • Mechanical properties of the upper airway wall in children and their influence on respiratory impedance measurements
    • Marchal F, Haouzi P, Peslin R, Duvivier C, Gallina C 1992 Mechanical properties of the upper airway wall in children and their influence on respiratory impedance measurements. Pediatr Pulmonol 13:28-33
    • (1992) Pediatr Pulmonol , vol.13 , pp. 28-33
    • Marchal, F.1    Haouzi, P.2    Peslin, R.3    Duvivier, C.4    Gallina, C.5
  • 5
    • 0024413703 scopus 로고
    • Effect of upper airway shunt and series properties on respiratory impedance measurements
    • Cauberghs M, Van de Woestijne KP 1989 Effect of upper airway shunt and series properties on respiratory impedance measurements. J Appl Physiol 66:2274-2279
    • (1989) J Appl Physiol , vol.66 , pp. 2274-2279
    • Cauberghs, M.1    Van de Woestijne, K.P.2
  • 6
    • 0016695114 scopus 로고
    • Pulmonary mechanics by spectral analysis of forced random noise
    • Michaelson ED, Grassman ED, Peters WR 1975 Pulmonary mechanics by spectral analysis of forced random noise. J Clin Invest 56:1210-1230
    • (1975) J Clin Invest , vol.56 , pp. 1210-1230
    • Michaelson, E.D.1    Grassman, E.D.2    Peters, W.R.3
  • 7
    • 0022337588 scopus 로고
    • Respiratory impedance measured with head generator to minimize upper airway shunt
    • Peslin R, Duvivier C, Didelon J, Gallina C 1985 Respiratory impedance measured with head generator to minimize upper airway shunt. J Appl Physiol 59:1790-1795
    • (1985) J Appl Physiol , vol.59 , pp. 1790-1795
    • Peslin, R.1    Duvivier, C.2    Didelon, J.3    Gallina, C.4
  • 8
    • 0032693750 scopus 로고    scopus 로고
    • Methacholine-induced volume dependence of respiratory resistance in preschool children
    • Marchal F, Loos N, Monin P, Peslin R 1999 Methacholine-induced volume dependence of respiratory resistance in preschool children. Eur Respir J 14:1167-1174
    • (1999) Eur Respir J , vol.14 , pp. 1167-1174
    • Marchal, F.1    Loos, N.2    Monin, P.3    Peslin, R.4
  • 9
  • 10
    • 0032957596 scopus 로고    scopus 로고
    • Assessment of bronchial reactivity by forced oscillation admittance avoids the upper airway artefact
    • Farre R, Rotger M, Marchal F, Peslin R, Navajas D 1999 Assessment of bronchial reactivity by forced oscillation admittance avoids the upper airway artefact. Eur Respir J 13:761-766
    • (1999) Eur Respir J , vol.13 , pp. 761-766
    • Farre, R.1    Rotger, M.2    Marchal, F.3    Peslin, R.4    Navajas, D.5
  • 11
    • 0024206039 scopus 로고
    • A new estimator to minimize the error due to breathing in the measurement of respiratory impedance
    • Navajas D, Farre R, Rotger M, Peslin R 1988 A new estimator to minimize the error due to breathing in the measurement of respiratory impedance. IEEE Trans Biomed Eng 35:1001-1005
    • (1988) IEEE Trans Biomed Eng , vol.35 , pp. 1001-1005
    • Navajas, D.1    Farre, R.2    Rotger, M.3    Peslin, R.4
  • 12
    • 7044271129 scopus 로고    scopus 로고
    • Filtering artefacts in measurements of forced oscillation respiratory impedance in young children
    • Marchal F, Schweitzer C, Demoulin B, Chone C, Peslin R 2004 Filtering artefacts in measurements of forced oscillation respiratory impedance in young children. Physiol Meas 25:1153-1166
    • (2004) Physiol Meas , vol.25 , pp. 1153-1166
    • Marchal, F.1    Schweitzer, C.2    Demoulin, B.3    Chone, C.4    Peslin, R.5
  • 13
    • 0348219118 scopus 로고    scopus 로고
    • Influence of data filtering on reliability of respiratory impedance and derived parameters in children
    • Schweitzer C, Chone C, Marchal F 2003 Influence of data filtering on reliability of respiratory impedance and derived parameters in children. Pediatr Pulmonol 36:502-508
    • (2003) Pediatr Pulmonol , vol.36 , pp. 502-508
    • Schweitzer, C.1    Chone, C.2    Marchal, F.3
  • 16
    • 0035881016 scopus 로고    scopus 로고
    • Discriminative capacity of bronchodilator response measured with three different lung function techniques in asthmatic and healthy children aged 2 to 5 years
    • Nielsen KG, Bisgaard H 2001 Discriminative capacity of bronchodilator response measured with three different lung function techniques in asthmatic and healthy children aged 2 to 5 years. Am J Respir Crit Care Med 164:554-559
    • (2001) Am J Respir Crit Care Med , vol.164 , pp. 554-559
    • Nielsen, K.G.1    Bisgaard, H.2
  • 17
    • 0028956029 scopus 로고
    • Specificity and sensitivity of respiratory impedance in assessing reversibility of airway obstruction in children
    • Mazurek HK, Marchal F, Derelle J, Hatahet R, Moneret-Vautrin D, Monin P 1995 Specificity and sensitivity of respiratory impedance in assessing reversibility of airway obstruction in children. Chest 107:996-1002
    • (1995) Chest , vol.107 , pp. 996-1002
    • Mazurek, H.K.1    Marchal, F.2    Derelle, J.3    Hatahet, R.4    Moneret-Vautrin, D.5    Monin, P.6
  • 18
    • 0015620179 scopus 로고
    • The variable effect of a bronchodilating agent on pulmonary function in cystic fibrosis
    • Landau LI, Phelan PD 1973 The variable effect of a bronchodilating agent on pulmonary function in cystic fibrosis. J Pediatr 82:863-868
    • (1973) J Pediatr , vol.82 , pp. 863-868
    • Landau, L.I.1    Phelan, P.D.2
  • 19
  • 20
    • 0031963278 scopus 로고    scopus 로고
    • No paradoxical bronchodilator response with forced oscillation technique in children with cystic fibrosis
    • Hellinckx J, De Boeck K, Demedts M 1998 No paradoxical bronchodilator response with forced oscillation technique in children with cystic fibrosis. Chest 113:55-59
    • (1998) Chest , vol.113 , pp. 55-59
    • Hellinckx, J.1    De Boeck, K.2    Demedts, M.3
  • 21
    • 22144466900 scopus 로고    scopus 로고
    • Variability analysis of oscillatory airway resistance in children
    • Trubel H, Banikol WK 2005 Variability analysis of oscillatory airway resistance in children. Eur J Appl Physiol 94:364-370
    • (2005) Eur J Appl Physiol , vol.94 , pp. 364-370
    • Trubel, H.1    Banikol, W.K.2
  • 22
    • 0346958337 scopus 로고    scopus 로고
    • Effects of respiratory timing and cheek support on resistance measurements, before and after bronchodilation in asthmatic children using the interrupter technique
    • Hadjikoumi I, Hassan A, Milner AD 2003 Effects of respiratory timing and cheek support on resistance measurements, before and after bronchodilation in asthmatic children using the interrupter technique. Pediatr Pulmonol 36:495-501
    • (2003) Pediatr Pulmonol , vol.36 , pp. 495-501
    • Hadjikoumi, I.1    Hassan, A.2    Milner, A.D.3
  • 23
    • 0001500014 scopus 로고
    • Oscillation mechanics of the respiratory system
    • Fishman P, Macklem PT, Mead J eds, section 3. Williams & Wilkins, Baltimore, pp
    • Peslin R, Fredberg J 1986 Oscillation mechanics of the respiratory system. In Fishman P, Macklem PT, Mead J (eds) Handbook of Physiology, section 3. Williams & Wilkins, Baltimore, pp 145-177
    • (1986) Handbook of Physiology , pp. 145-177
    • Peslin, R.1    Fredberg, J.2
  • 24
    • 28444484298 scopus 로고    scopus 로고
    • Forced oscillations, interrupter technique and body plethysmography in the preschool child
    • Marchal F, Schweitzer C, Thuy LV 2005 Forced oscillations, interrupter technique and body plethysmography in the preschool child. Paediatr Respir Rev 6:278-284
    • (2005) Paediatr Respir Rev , vol.6 , pp. 278-284
    • Marchal, F.1    Schweitzer, C.2    Thuy, L.V.3
  • 25
    • 0028270331 scopus 로고
    • Input respiratory impedance to estimate airway hyperreactivity in children: Standard method versus head generator
    • Marchal F, Mazurek H, Habib M, Duvivier C, Derelle J, Peslin R 1994 Input respiratory impedance to estimate airway hyperreactivity in children: standard method versus head generator. Eur Respir J 7:601-607
    • (1994) Eur Respir J , vol.7 , pp. 601-607
    • Marchal, F.1    Mazurek, H.2    Habib, M.3    Duvivier, C.4    Derelle, J.5    Peslin, R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.