메뉴 건너뛰기




Volumn 31, Issue 5, 2007, Pages 351-360

Mathematical model of an amperometric biosensor for the design of an appropriate instrumentation system

Author keywords

Amperometric biosensor; Enzyme layer; Instrumentation; Substrate

Indexed keywords

AMPEROMETRIC SENSORS; KINETIC THEORY; LIQUID CHROMATOGRAPHY; MATHEMATICAL MODELS; REACTION KINETICS; SUBSTRATES;

EID: 34548092467     PISSN: 03091902     EISSN: 1464522X     Source Type: Journal    
DOI: 10.1080/03091900600926898     Document Type: Article
Times cited : (5)

References (19)
  • 1
    • 0000794840 scopus 로고
    • Medical application of the glucose sensor
    • T. Seiyama Ed, Amsterdam: Elsevier
    • Sichiri, M., Kawamori, R., Yamasaki, N. and Ueda, N., 1988, Medical application of the glucose sensor. In Chemical Sensor Technology, T. Seiyama (Ed.), 1, p. 209 (Amsterdam: Elsevier).
    • (1988) Chemical Sensor Technology , vol.1 , pp. 209
    • Sichiri, M.1    Kawamori, R.2    Yamasaki, N.3    Ueda, N.4
  • 3
    • 10244223555 scopus 로고
    • Electrode system for continuous monitoring in cardivascular surgery
    • Clark Jr, L.C. and Lyons, C., 1962, Electrode system for continuous monitoring in cardivascular surgery. Annals of the New York Academy of Science, 102, 29-45.
    • (1962) Annals of the New York Academy of Science , vol.102 , pp. 29-45
    • Clark Jr, L.C.1    Lyons, C.2
  • 4
    • 0014191637 scopus 로고
    • The enzyme electrode
    • Updike, S.J. and Hicks, J.P, 1967, The enzyme electrode. Nature, 214, 986-988.
    • (1967) Nature , vol.214 , pp. 986-988
    • Updike, S.J.1    Hicks, J.P.2
  • 6
    • 0034324759 scopus 로고    scopus 로고
    • Ascorbic acid oxidase based biosensor for organophosphorus pesticide detection
    • Rekha, K., Gouda, M.G. and Thakur, M.S., 2000, Ascorbic acid oxidase based biosensor for organophosphorus pesticide detection. Biosensors and Bioelectronics, 15, 499-502.
    • (2000) Biosensors and Bioelectronics , vol.15 , pp. 499-502
    • Rekha, K.1    Gouda, M.G.2    Thakur, M.S.3
  • 7
    • 0039260381 scopus 로고
    • Chemical micro sensors and micro instrumentation. 5
    • Wohltjen, H., 1984, Chemical micro sensors and micro instrumentation. 5 Analytical Chemistry, 56, 87-103.
    • (1984) Analytical Chemistry , vol.56 , pp. 87-103
    • Wohltjen, H.1
  • 8
    • 85153233587 scopus 로고    scopus 로고
    • Gouda, M.D., Thakur, M.S. and Karanth, N.G., 2001, 2001, Stability studies on immobilized glucose oxidase using an amperometric biosensor: Effect of protein based stabilizing agents. Electroanalysis, 1, 849-855.
    • Gouda, M.D., Thakur, M.S. and Karanth, N.G., 2001, 2001, Stability studies on immobilized glucose oxidase using an amperometric biosensor: Effect of protein based stabilizing agents. Electroanalysis, 1, 849-855.
  • 10
    • 0035191026 scopus 로고    scopus 로고
    • Optimization of the multienzyme system for sucrose biosensor by response surface methodology
    • Gouda, M.D., Thakur, M.S. and Karanth, N.G., 2001, Optimization of the multienzyme system for sucrose biosensor by response surface methodology. Microbiology and Biotechnology, 17, 595-600.
    • (2001) Microbiology and Biotechnology , vol.17 , pp. 595-600
    • Gouda, M.D.1    Thakur, M.S.2    Karanth, N.G.3
  • 12
    • 3142741545 scopus 로고    scopus 로고
    • Computer simulation of the response of amperometric biosensors in stirred and non stirred solution
    • Baronus, R., Ivanauskas, E. and Kulys, J., 2003, Computer simulation of the response of amperometric biosensors in stirred and non stirred solution. Nonlinear Analysis: Modeling and control, 8, 3-18.
    • (2003) Nonlinear Analysis: Modeling and control , vol.8 , pp. 3-18
    • Baronus, R.1    Ivanauskas, E.2    Kulys, J.3
  • 14
    • 0026850019 scopus 로고
    • Transient response of electrochemical biosensors with a symmetrical sandwich membranes
    • Iliev, I., Atanasov, P., Gamburzev, S. and Kaisheva, A., 1992, Transient response of electrochemical biosensors with a symmetrical sandwich membranes. Sensors and Actuators, 8, 65-72.
    • (1992) Sensors and Actuators , vol.8 , pp. 65-72
    • Iliev, I.1    Atanasov, P.2    Gamburzev, S.3    Kaisheva, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.