메뉴 건너뛰기




Volumn 29, Issue 9, 2007, Pages 647-655

Evaluation of thermal conductivity in air permeable concrete for dynamic breathing wall construction

Author keywords

Air permeable concrete; Dynamic insulation; Energy efficiency; Heat recovery; Thermal conductivity

Indexed keywords

AIR PERMEABILITY; CONCRETE CONSTRUCTION; ENERGY EFFICIENCY; THERMAL CONDUCTIVITY; WASTE HEAT UTILIZATION;

EID: 34548081234     PISSN: 09589465     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cemconcomp.2007.04.008     Document Type: Article
Times cited : (68)

References (15)
  • 1
    • 0030283817 scopus 로고    scopus 로고
    • Analytical investigation of the steady state behaviour of dynamic and diffusive building envelopes
    • Taylor B.J., Cawthorne D.A., and Imbabi M.S. Analytical investigation of the steady state behaviour of dynamic and diffusive building envelopes. Build Environ 31 6 (1996) 519-525
    • (1996) Build Environ , vol.31 , Issue.6 , pp. 519-525
    • Taylor, B.J.1    Cawthorne, D.A.2    Imbabi, M.S.3
  • 2
    • 0030109488 scopus 로고    scopus 로고
    • Effective thermal conductivity of granular porous materials
    • Tavman I.H. Effective thermal conductivity of granular porous materials. Int Commun Heat Mass Transfer 23 2 (1996) 169-176
    • (1996) Int Commun Heat Mass Transfer , vol.23 , Issue.2 , pp. 169-176
    • Tavman, I.H.1
  • 3
    • 4344608082 scopus 로고    scopus 로고
    • Effective thermal conductivity of highly porous two-phase system
    • Jagjiwanram R.S. Effective thermal conductivity of highly porous two-phase system. Appl Therm Eng 24 17-18 (2004) 2727-2735
    • (2004) Appl Therm Eng , vol.24 , Issue.17-18 , pp. 2727-2735
    • Jagjiwanram, R.S.1
  • 4
    • 0026222434 scopus 로고
    • Prediction and measurement of effective thermal conductivity of three-phase systems
    • Verma L.S., Shrotriya A.K., Singh R., and Chaudhary D.R. Prediction and measurement of effective thermal conductivity of three-phase systems. J Phys D: Appl Phys 24 9 (1991) 1515-1526
    • (1991) J Phys D: Appl Phys , vol.24 , Issue.9 , pp. 1515-1526
    • Verma, L.S.1    Shrotriya, A.K.2    Singh, R.3    Chaudhary, D.R.4
  • 5
    • 0037349151 scopus 로고    scopus 로고
    • An experimental study on thermal conductivity of concrete
    • Kim K., Jeon S., Kim J., and Yang S. An experimental study on thermal conductivity of concrete. Cement Concrete Res 33 3 (2003) 363-371
    • (2003) Cement Concrete Res , vol.33 , Issue.3 , pp. 363-371
    • Kim, K.1    Jeon, S.2    Kim, J.3    Yang, S.4
  • 8
    • 0035322190 scopus 로고    scopus 로고
    • Effects of various shape parameters on packings of aggregate particles
    • Kwan A.K.H., and Mora C.F. Effects of various shape parameters on packings of aggregate particles. Mag Concrete Res 53 2 (2001) 91-100
    • (2001) Mag Concrete Res , vol.53 , Issue.2 , pp. 91-100
    • Kwan, A.K.H.1    Mora, C.F.2
  • 10
    • 34548060525 scopus 로고    scopus 로고
    • Breathable concrete for low energy building
    • Imbabi M.S., and Mitchell C.P. (Eds), Elsevier, Aberdeen
    • Wong J.M., Glasser F.P., and Imbabi M.S. Breathable concrete for low energy building. In: Imbabi M.S., and Mitchell C.P. (Eds). World renewable energy congress (2005), Elsevier, Aberdeen
    • (2005) World renewable energy congress
    • Wong, J.M.1    Glasser, F.P.2    Imbabi, M.S.3
  • 11
    • 0034312652 scopus 로고    scopus 로고
    • Transient hot wire (THW) method: uncertainty assessment
    • Hammerschmidt U., and Sabuga W. Transient hot wire (THW) method: uncertainty assessment. Int J Thermophys 21 6 (2000) 1255-1278
    • (2000) Int J Thermophys , vol.21 , Issue.6 , pp. 1255-1278
    • Hammerschmidt, U.1    Sabuga, W.2
  • 12
    • 0036181176 scopus 로고    scopus 로고
    • Uncertainty of the thermal conductivity measurement using the transient hot wire method
    • Labudova G., and Vozarova V. Uncertainty of the thermal conductivity measurement using the transient hot wire method. J Therm Anal Calorim 67 1 (2002) 257-265
    • (2002) J Therm Anal Calorim , vol.67 , Issue.1 , pp. 257-265
    • Labudova, G.1    Vozarova, V.2
  • 13
    • 0035546724 scopus 로고    scopus 로고
    • Effective thermal conductivity of Mexican geothermal cementing system in the temperature range from 28 °C to 200 °C
    • Santoyo E., Garcia A., and Morales J.M. Effective thermal conductivity of Mexican geothermal cementing system in the temperature range from 28 °C to 200 °C. Appl Therm Eng 21 17 (2001) 1799-1812
    • (2001) Appl Therm Eng , vol.21 , Issue.17 , pp. 1799-1812
    • Santoyo, E.1    Garcia, A.2    Morales, J.M.3
  • 14
    • 0034329368 scopus 로고    scopus 로고
    • Quantification of the relationship between porosity and interparticle forces for the packing of wet uniform spheres
    • Feng C.L., and Yu A.B. Quantification of the relationship between porosity and interparticle forces for the packing of wet uniform spheres. J Colloid Interface Sci 231 1 (2000) 136-142
    • (2000) J Colloid Interface Sci , vol.231 , Issue.1 , pp. 136-142
    • Feng, C.L.1    Yu, A.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.