메뉴 건너뛰기




Volumn 113 PART 1, Issue , 2007, Pages 470-476

A fast algorithm for the simulation of GCHP systems

Author keywords

[No Author keywords available]

Indexed keywords

BOREHOLES; GEOTHERMAL ENERGY; HEAT TRANSFER; MATHEMATICAL MODELS; TEMPERATURE MEASUREMENT;

EID: 34547975732     PISSN: 00012505     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (23)

References (13)
  • 1
    • 0034832568 scopus 로고    scopus 로고
    • Ground-coupled heat pump system simulation
    • Bernier, M. 2001. Ground-coupled heat pump system simulation. ASHRAE Transactions 106(1):605-16.
    • (2001) ASHRAE Transactions , vol.106 , Issue.1 , pp. 605-616
    • Bernier, M.1
  • 2
    • 7244233029 scopus 로고    scopus 로고
    • A multiple load aggregation for annual hourly simulations of GCHP systems
    • Bernier, M., P. Pinel, R. Labib, and R. Paillot. 2004. A multiple load aggregation for annual hourly simulations of GCHP systems, HVAC&R Research 10(4):471-87.
    • (2004) HVAC&R Research , vol.10 , Issue.4 , pp. 471-487
    • Bernier, M.1    Pinel, P.2    Labib, R.3    Paillot, R.4
  • 6
    • 84990587865 scopus 로고    scopus 로고
    • Greengard, L., and J. Strain. 1990. A fast algorithm for the evaluation of heat potentials. Comm on Pure and Applied Mathematics 43:949-63.
    • Greengard, L., and J. Strain. 1990. A fast algorithm for the evaluation of heat potentials. Comm on Pure and Applied Mathematics 43:949-63.
  • 8
    • 0003973615 scopus 로고
    • 2nd ed. New York: John Wiley
    • Ozisik, M. 1993. Heat Conduction, 2nd ed. New York: John Wiley.
    • (1993) Heat Conduction
    • Ozisik, M.1
  • 10
    • 0033315319 scopus 로고    scopus 로고
    • A new comparison of vertical ground exchanger design methods for residential applications
    • Shonder, J., V. Baxter, J. Thornton, and P. Hughes 1999. A new comparison of vertical ground exchanger design methods for residential applications. ASHRAE Transactions 105(2): 1179-88.
    • (1999) ASHRAE Transactions , vol.105 , Issue.2 , pp. 1179-1188
    • Shonder, J.1    Baxter, V.2    Thornton, J.3    Hughes, P.4
  • 12
    • 0033309869 scopus 로고    scopus 로고
    • A short time step response factor model for vertical ground loop heat exchangers
    • Yavuzturk, C., and J. Spitler. 1999. A short time step response factor model for vertical ground loop heat exchangers. ASHRAE Transactions 105(2):475.
    • (1999) ASHRAE Transactions , vol.105 , Issue.2 , pp. 475
    • Yavuzturk, C.1    Spitler, J.2
  • 13
    • 0036870964 scopus 로고    scopus 로고
    • A finite line-source model for boreholes in geothermal heat exchangers
    • Zeng, H., N. Diao, and Z. Fang 2002. A finite line-source model for boreholes in geothermal heat exchangers. Heat Transfer Asian Research 31(7):558-67.
    • (2002) Heat Transfer Asian Research , vol.31 , Issue.7 , pp. 558-567
    • Zeng, H.1    Diao, N.2    Fang, Z.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.