메뉴 건너뛰기




Volumn 113 PART 1, Issue , 2007, Pages 358-365

Evaluating RNG k-ε models using PIV data for airflow in animal buildings at different ventilation rates

Author keywords

[No Author keywords available]

Indexed keywords

FLOW VELOCITY; MEAN SQUARE ERROR; REYNOLDS NUMBER; TURBULENCE MODELS; TURBULENT FLOW; VENTILATION;

EID: 34547963845     PISSN: 00012505     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (9)

References (26)
  • 1
    • 34547969002 scopus 로고    scopus 로고
    • ASTM. 2002. Standard guide for statistical evaluation of indoor air quality models (D5157-97). In Annual Book of American Society for Testing Materials Standards, p. 11.03. West Conshohocken, PA: American Society for Testing and Materials.
    • ASTM. 2002. Standard guide for statistical evaluation of indoor air quality models (D5157-97). In Annual Book of American Society for Testing Materials Standards, p. 11.03. West Conshohocken, PA: American Society for Testing and Materials.
  • 2
    • 0000421293 scopus 로고    scopus 로고
    • Three-dimensional airflow in a livestock test room with two-dimensional boundary conditions
    • Bjerg, B., S. Morsing, K. Svidt, and D. Zhang. 1999. Three-dimensional airflow in a livestock test room with two-dimensional boundary conditions. J. Agric. Eng. Res. 74 (3): 267-74.
    • (1999) J. Agric. Eng. Res , vol.74 , Issue.3 , pp. 267-274
    • Bjerg, B.1    Morsing, S.2    Svidt, K.3    Zhang, D.4
  • 3
    • 0005845347 scopus 로고    scopus 로고
    • The effect of pen partitions and thermal pig simulators on airflow in a livestock test room
    • Bjerg, B., K. Svidt, D. Zhang, and S. Morsing. 2000. The effect of pen partitions and thermal pig simulators on airflow in a livestock test room. J. Agric. Eng. Res. 77: 317-26.
    • (2000) J. Agric. Eng. Res , vol.77 , pp. 317-326
    • Bjerg, B.1    Svidt, K.2    Zhang, D.3    Morsing, S.4
  • 4
    • 0032420219 scopus 로고    scopus 로고
    • Ammonia exposure: A common cause for sinusitis, a case report and review of the literature
    • Brautbar, N. 1998. Ammonia exposure: A common cause for sinusitis, a case report and review of the literature. Toxicology and Industrial Health 14(6):49-60.
    • (1998) Toxicology and Industrial Health , vol.14 , Issue.6 , pp. 49-60
    • Brautbar, N.1
  • 5
    • 0030687308 scopus 로고    scopus 로고
    • Computational fluid dynamics for HVAC: Success and failure
    • Chen, Q. 1997. Computational fluid dynamics for HVAC: success and failure. ASHRAE Transactions 103(1):178-87.
    • (1997) ASHRAE Transactions , vol.103 , Issue.1 , pp. 178-187
    • Chen, Q.1
  • 8
    • 0011783527 scopus 로고    scopus 로고
    • FLUENT, Lebanon, NH: Fluent, Inc
    • FLUENT. 2002. Fluent 6.0 User's Guide. Lebanon, NH: Fluent, Inc.
    • (2002) Fluent 6.0 User's Guide
  • 9
    • 0029531375 scopus 로고
    • Evaluation of room air distribution systems using computational fluid dynamics
    • Gan, G. 1995. Evaluation of room air distribution systems using computational fluid dynamics. Energy and Building 23:83-93.
    • (1995) Energy and Building , vol.23 , pp. 83-93
    • Gan, G.1
  • 10
    • 0028347439 scopus 로고
    • Effects of atmospheric ammonia on pulmonary hemodynamics and vascular permeability in pigs: Interaction with endotoxins
    • Gustin, P., B. Urbain, J., Prouvost, and M. Ansay. 1994, Effects of atmospheric ammonia on pulmonary hemodynamics and vascular permeability in pigs: Interaction with endotoxins. Toxicology and Applied Pharmacology 125:17-26.
    • (1994) Toxicology and Applied Pharmacology , vol.125 , pp. 17-26
    • Gustin, P.1    Urbain, B.2    Prouvost, J.3    Ansay, M.4
  • 11
    • 0000584034 scopus 로고    scopus 로고
    • Comparison of predicted and measured airflow patterns in a mechanically ventilated livestock without animals
    • Harral, B.B., and C.R. Boon. 1997. Comparison of predicted and measured airflow patterns in a mechanically ventilated livestock without animals. J. Agric. Eng. Res. 66 (3):221-28.
    • (1997) J. Agric. Eng. Res , vol.66 , Issue.3 , pp. 221-228
    • Harral, B.B.1    Boon, C.R.2
  • 14
    • 0036766838 scopus 로고    scopus 로고
    • Two-dimensional computational fluid dynamics (CFD) modeling of air and ammonia distribution in a High-rise™ Hog Building (HRHB)
    • Sun, H., H. Keener, R.R. Stowell, and F.C. Michel, Jr. 2002. Two-dimensional computational fluid dynamics (CFD) modeling of air and ammonia distribution in a High-rise™ Hog Building (HRHB). Trans. ASAE 45(5):1559-68.
    • (2002) Trans. ASAE , vol.45 , Issue.5 , pp. 1559-1568
    • Sun, H.1    Keener, H.2    Stowell, R.R.3    Michel Jr., F.C.4
  • 15
    • 34547974159 scopus 로고    scopus 로고
    • Sun, H., H. Keener, W. Deng, and F.C. Michel, Jr. 2004. 3-D CFD models of airflow and ammonia distributions in a High-Rise Hog Building during summer and winter conditions. CGIR E-journal, VI, Manuscript BC 04 004, pp. 1-24.
    • Sun, H., H. Keener, W. Deng, and F.C. Michel, Jr. 2004. 3-D CFD models of airflow and ammonia distributions in a High-Rise Hog Building during summer and winter conditions. CGIR E-journal, Vol. VI, Manuscript BC 04 004, pp. 1-24.
  • 16
    • 34547981322 scopus 로고    scopus 로고
    • Evaluation of RNG κ-ε and LES non-isothermal models for indoor airflow using PIV measurement data
    • submitted
    • Sun, H., L. Zhao, Y. Zhang, and L.L. Christianson. 2006. Evaluation of RNG κ-ε and LES non-isothermal models for indoor airflow using PIV measurement data. ASABE Transactions, submitted.
    • (2006) ASABE Transactions
    • Sun, H.1    Zhao, L.2    Zhang, Y.3    Christianson, L.L.4
  • 19
    • 0022983754 scopus 로고
    • Renormalization group analysis of turbulence: I. Basic theory
    • Yakhot, V., and S.A. Orszag. 1986. Renormalization group analysis of turbulence: I. Basic theory. Journal of Scientific Computing 1(1):1-51.
    • (1986) Journal of Scientific Computing , vol.1 , Issue.1 , pp. 1-51
    • Yakhot, V.1    Orszag, S.A.2
  • 22
    • 33751178247 scopus 로고
    • Regional airflow characteristics in a mechanically ventilated room under non-isothermal conditions
    • Zhang, J.S., L.L. Christianson, and G.L. Riskowski. 1989. Regional airflow characteristics in a mechanically ventilated room under non-isothermal conditions. ASHRAE Transactions 95(2):751-59.
    • (1989) ASHRAE Transactions , vol.95 , Issue.2 , pp. 751-759
    • Zhang, J.S.1    Christianson, L.L.2    Riskowski, G.L.3
  • 23
    • 0026982051 scopus 로고
    • Detailed measurements of room air distribution for evaluation numerical simulation models
    • Zhang, J.S., L.L.Christianson, G.J. Wu, and G.L. Riskowski. 1992. Detailed measurements of room air distribution for evaluation numerical simulation models. ASHRAE Transactions 98(1):58-65.
    • (1992) ASHRAE Transactions , vol.98 , Issue.1 , pp. 58-65
    • Zhang, J.S.1    Christianson, L.L.2    Wu, G.J.3    Riskowski, G.L.4
  • 24
    • 0033346513 scopus 로고    scopus 로고
    • Development of particle image velocimetry techniques to measure room airflow patterns in ventilated airspaces
    • Zhao, L.Y, Y. Zhang, X. Wang, G.L. Riskowski, and L.L. Christianson. 1999. Development of particle image velocimetry techniques to measure room airflow patterns in ventilated airspaces. ASHRAE Transactions 105(2):1098-1107.
    • (1999) ASHRAE Transactions , vol.105 , Issue.2 , pp. 1098-1107
    • Zhao, L.Y.1    Zhang, Y.2    Wang, X.3    Riskowski, G.L.4    Christianson, L.L.5
  • 26
    • 0035571475 scopus 로고    scopus 로고
    • Measurement of 2-D air velocity in a full-scale room using a particle image velocimetry system
    • Zhao, L.Y., Y. Zhang, X. Wang, G.L. Riskowski, and L.L. Christianson. 2001. Measurement of 2-D air velocity in a full-scale room using a particle image velocimetry system. ASHRAE Transactions 107(2):434-44.
    • (2001) ASHRAE Transactions , vol.107 , Issue.2 , pp. 434-444
    • Zhao, L.Y.1    Zhang, Y.2    Wang, X.3    Riskowski, G.L.4    Christianson, L.L.5