메뉴 건너뛰기




Volumn 65, Issue 9, 2007, Pages 1859-1861

Biodegradable Screw Fixation in Maxillofacial Distraction Osteogenesis

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; BIODEGRADABLE IMPLANT; BONE SCREW; CASE REPORT; DISTRACTION OSTEOGENESIS; FEMALE; HUMAN; MALOCCLUSION; MAXILLOFACIAL SURGERY; SURGICAL TECHNIQUE; TOOTH RADIOGRAPHY;

EID: 34547929243     PISSN: 02782391     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.joms.2006.05.055     Document Type: Article
Times cited : (4)

References (9)
  • 1
    • 29144477295 scopus 로고    scopus 로고
    • The use of biodegradable plates and screws to stabilize facial fractures
    • Bell R.B., and Kindsfater C.S. The use of biodegradable plates and screws to stabilize facial fractures. J Oral Maxillofac Surg 64 (2006) 31
    • (2006) J Oral Maxillofac Surg , vol.64 , pp. 31
    • Bell, R.B.1    Kindsfater, C.S.2
  • 2
    • 29144504069 scopus 로고    scopus 로고
    • Self-reinforced biodegradable screw fixation compared with titanium screw fixation in mandibular advancement
    • Turvey T.A., Bell R.B., Phillips C., et al. Self-reinforced biodegradable screw fixation compared with titanium screw fixation in mandibular advancement. J Oral Maxillofac Surg 64 (2006) 40
    • (2006) J Oral Maxillofac Surg , vol.64 , pp. 40
    • Turvey, T.A.1    Bell, R.B.2    Phillips, C.3
  • 3
    • 23944508063 scopus 로고    scopus 로고
    • Use of an alveolar distraction device for repositioning the maxillary segment to correct facial asymmetry of the maxillomandibular complex
    • Yamauchi K., Kanno T., Ariyoshi W., et al. Use of an alveolar distraction device for repositioning the maxillary segment to correct facial asymmetry of the maxillomandibular complex. J Oral Maxillofac Surg 63 (2005) 1398
    • (2005) J Oral Maxillofac Surg , vol.63 , pp. 1398
    • Yamauchi, K.1    Kanno, T.2    Ariyoshi, W.3
  • 5
    • 0030908235 scopus 로고    scopus 로고
    • Degradation characteristics of PLLA-PGA bone fixation devices
    • Eppley B.L., and Relly M. Degradation characteristics of PLLA-PGA bone fixation devices. J Craniofac Surg 8 (1997) 116
    • (1997) J Craniofac Surg , vol.8 , pp. 116
    • Eppley, B.L.1    Relly, M.2
  • 6
    • 0035095856 scopus 로고    scopus 로고
    • Fixation of bimaxillary osteotomies with resorbable plates and screws: Experience in 20 consecutive cases
    • Richard G.E., Kevin D.K., et al. Fixation of bimaxillary osteotomies with resorbable plates and screws: Experience in 20 consecutive cases. J Oral Maxillofac Surg 59 (2001) 271
    • (2001) J Oral Maxillofac Surg , vol.59 , pp. 271
    • Richard, G.E.1    Kevin, D.K.2
  • 7
    • 0031802474 scopus 로고    scopus 로고
    • Resorbable fixation of Le Fort I osteotomies
    • Richard G.E., and Kevin D.K. Resorbable fixation of Le Fort I osteotomies. J Craniofac Surg 9 (1998) 210
    • (1998) J Craniofac Surg , vol.9 , pp. 210
    • Richard, G.E.1    Kevin, D.K.2
  • 8
    • 0035745696 scopus 로고    scopus 로고
    • Internal Le Fort III distraction with biodegradable devices
    • Cohen S.R., and Holmes R.E. Internal Le Fort III distraction with biodegradable devices. J Craniofac Surg 12 (2001) 264
    • (2001) J Craniofac Surg , vol.12 , pp. 264
    • Cohen, S.R.1    Holmes, R.E.2
  • 9
    • 13244271948 scopus 로고    scopus 로고
    • Mandibular distraction osteogenesis in Pierre Robin sequence: Application of new internal single-stage resorbable device
    • Burstein F.D., and Williams J.K. Mandibular distraction osteogenesis in Pierre Robin sequence: Application of new internal single-stage resorbable device. Plast Reconstr Surg 115 (2005) 61
    • (2005) Plast Reconstr Surg , vol.115 , pp. 61
    • Burstein, F.D.1    Williams, J.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.