메뉴 건너뛰기




Volumn 50, Issue 3, 2007, Pages 258-263

A Comparison of Plastic Single-Use With Metallic Reusable Laryngoscope Blades for Out-of-Hospital Tracheal Intubation

Author keywords

[No Author keywords available]

Indexed keywords

ETOMIDATE; KETAMINE; PLASTIC; SUXAMETHONIUM; THIOPENTAL;

EID: 34547901069     PISSN: 01960644     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.annemergmed.2007.04.022     Document Type: Article
Times cited : (30)

References (23)
  • 1
    • 10044242511 scopus 로고    scopus 로고
    • The incidence and risk factors for cardiac arrest during emergency tracheal intubation: a justification for incorporating the ASA guidelines in the remote location
    • Mort T.C. The incidence and risk factors for cardiac arrest during emergency tracheal intubation: a justification for incorporating the ASA guidelines in the remote location. J Clin Anesth 16 (2004) 508-516
    • (2004) J Clin Anesth , vol.16 , pp. 508-516
    • Mort, T.C.1
  • 2
    • 3242753402 scopus 로고    scopus 로고
    • Emergency tracheal intubation: complications associated with repeated laryngoscopic attempts
    • Mort T.C. Emergency tracheal intubation: complications associated with repeated laryngoscopic attempts. Anesth Analg 99 (2004) 607-613
    • (2004) Anesth Analg , vol.99 , pp. 607-613
    • Mort, T.C.1
  • 3
    • 20444414506 scopus 로고    scopus 로고
    • Esophageal intubation with indirect clinical tests during emergency tracheal intubation: a report on patient morbidity
    • Mort T.C. Esophageal intubation with indirect clinical tests during emergency tracheal intubation: a report on patient morbidity. J Clin Anesth 17 (2005) 255-262
    • (2005) J Clin Anesth , vol.17 , pp. 255-262
    • Mort, T.C.1
  • 4
    • 33645288262 scopus 로고    scopus 로고
    • How many attempts are required to accomplish out-of-hospital endotracheal intubation?
    • Wang H.E., and Yealy D.M. How many attempts are required to accomplish out-of-hospital endotracheal intubation?. Acad Emerg Med 13 (2006) 372-377
    • (2006) Acad Emerg Med , vol.13 , pp. 372-377
    • Wang, H.E.1    Yealy, D.M.2
  • 5
    • 0344861811 scopus 로고    scopus 로고
    • Incidence of transient hypoxia and pulse rate reactivity during paramedic rapid sequence intubation
    • Dunford J.V., Davis D.P., Ochs M., et al. Incidence of transient hypoxia and pulse rate reactivity during paramedic rapid sequence intubation. Ann Emerg Med 42 (2003) 721-728
    • (2003) Ann Emerg Med , vol.42 , pp. 721-728
    • Dunford, J.V.1    Davis, D.P.2    Ochs, M.3
  • 6
    • 0032885497 scopus 로고    scopus 로고
    • MRSA contamination of a laryngoscope blade: a potential vector for cross infection
    • Beamer J.E., and Cox R.A. MRSA contamination of a laryngoscope blade: a potential vector for cross infection. Anaesthesia 54 (1999) 1010-1011
    • (1999) Anaesthesia , vol.54 , pp. 1010-1011
    • Beamer, J.E.1    Cox, R.A.2
  • 7
    • 21344463374 scopus 로고    scopus 로고
    • Lymphocyte contamination of laryngoscope blades: a possible vector for transmission of variant Creutzfeldt-Jakob disease
    • Hirsch N., Beckett A., Collinge J., et al. Lymphocyte contamination of laryngoscope blades: a possible vector for transmission of variant Creutzfeldt-Jakob disease. Anaesthesia 60 (2005) 664-667
    • (2005) Anaesthesia , vol.60 , pp. 664-667
    • Hirsch, N.1    Beckett, A.2    Collinge, J.3
  • 8
    • 0031157584 scopus 로고    scopus 로고
    • Incidence of visible and occult blood on laryngoscope blades and handles
    • Phillips R.A., and Monaghan W.P. Incidence of visible and occult blood on laryngoscope blades and handles. AANA J 65 (1997) 241-246
    • (1997) AANA J , vol.65 , pp. 241-246
    • Phillips, R.A.1    Monaghan, W.P.2
  • 9
    • 0031015906 scopus 로고    scopus 로고
    • Diagnosis of new variant Creutzfeldt-Jakob disease by tonsil biopsy
    • Hill A.F., Zeidler M., Ironside J., et al. Diagnosis of new variant Creutzfeldt-Jakob disease by tonsil biopsy. Lancet 349 (1997) 99-100
    • (1997) Lancet , vol.349 , pp. 99-100
    • Hill, A.F.1    Zeidler, M.2    Ironside, J.3
  • 10
    • 10744231076 scopus 로고    scopus 로고
    • Disposable laryngoscope blades do not interfere with ease of intubation in scheduled general anaesthesia patients
    • Galinski M., Adnet F., Tran D., et al. Disposable laryngoscope blades do not interfere with ease of intubation in scheduled general anaesthesia patients. Eur J Anaesthesiol 20 (2003) 731-735
    • (2003) Eur J Anaesthesiol , vol.20 , pp. 731-735
    • Galinski, M.1    Adnet, F.2    Tran, D.3
  • 11
    • 0035071690 scopus 로고    scopus 로고
    • Evaluation of the disposable Vital View laryngoscope apparatus
    • Asai T., Uchiyama Y., Yamamoto K., et al. Evaluation of the disposable Vital View laryngoscope apparatus. Anaesthesia 56 (2001) 342-345
    • (2001) Anaesthesia , vol.56 , pp. 342-345
    • Asai, T.1    Uchiyama, Y.2    Yamamoto, K.3
  • 12
    • 0042326302 scopus 로고    scopus 로고
    • A comparison of the forces exerted during laryngoscopy using disposable and non-disposable laryngoscope blades
    • Evans A., Vaughan R.S., Hall J.E., et al. A comparison of the forces exerted during laryngoscopy using disposable and non-disposable laryngoscope blades. Anaesthesia 58 (2003) 869-873
    • (2003) Anaesthesia , vol.58 , pp. 869-873
    • Evans, A.1    Vaughan, R.S.2    Hall, J.E.3
  • 13
    • 15944396119 scopus 로고    scopus 로고
    • A comparison of 20 laryngoscope blades using an intubating manikin: visual analogue scores and forces exerted during laryngoscopy
    • Rassam S., Wilkes A.R., Hall J.E., et al. A comparison of 20 laryngoscope blades using an intubating manikin: visual analogue scores and forces exerted during laryngoscopy. Anaesthesia 60 (2005) 384-394
    • (2005) Anaesthesia , vol.60 , pp. 384-394
    • Rassam, S.1    Wilkes, A.R.2    Hall, J.E.3
  • 14
    • 33644857001 scopus 로고    scopus 로고
    • Comparison of plastic single-use and metal reusable laryngoscope blades for orotracheal intubation during rapid sequence induction of anesthesia
    • Amour J., Marmion F., Birenbaum A., et al. Comparison of plastic single-use and metal reusable laryngoscope blades for orotracheal intubation during rapid sequence induction of anesthesia. Anesthesiology 104 (2006) 60-64
    • (2006) Anesthesiology , vol.104 , pp. 60-64
    • Amour, J.1    Marmion, F.2    Birenbaum, A.3
  • 15
    • 0021701206 scopus 로고
    • Difficult tracheal intubation in obstetrics
    • Cormack R.S., and Lehane J. Difficult tracheal intubation in obstetrics. Anaesthesia 39 (1984) 1105-1111
    • (1984) Anaesthesia , vol.39 , pp. 1105-1111
    • Cormack, R.S.1    Lehane, J.2
  • 16
    • 0031469105 scopus 로고    scopus 로고
    • The Intubation Difficulty Scale (IDS): proposal and evaluation of a new score characterizing the complexity of endotracheal intubation
    • Adnet F., Borron S.W., Racine S.X., et al. The Intubation Difficulty Scale (IDS): proposal and evaluation of a new score characterizing the complexity of endotracheal intubation. Anesthesiology 87 (1997) 1290-1297
    • (1997) Anesthesiology , vol.87 , pp. 1290-1297
    • Adnet, F.1    Borron, S.W.2    Racine, S.X.3
  • 17
    • 33746369428 scopus 로고    scopus 로고
    • Prehospital standardization of medical airway management: incidence and risk factors of difficult airway
    • Combes X., Jabre P., Jbeili C., et al. Prehospital standardization of medical airway management: incidence and risk factors of difficult airway. Acad Emerg Med 13 (2006) 828-834
    • (2006) Acad Emerg Med , vol.13 , pp. 828-834
    • Combes, X.1    Jabre, P.2    Jbeili, C.3
  • 18
    • 0031746524 scopus 로고    scopus 로고
    • Emergency tracheal intubation of patients lying supine on the ground: influence of operator body position
    • Adnet F., Cydulka R.K., and Lapandry C. Emergency tracheal intubation of patients lying supine on the ground: influence of operator body position. Can J Anaesth 45 (1998) 266-269
    • (1998) Can J Anaesth , vol.45 , pp. 266-269
    • Adnet, F.1    Cydulka, R.K.2    Lapandry, C.3
  • 19
    • 4043176949 scopus 로고    scopus 로고
    • The impact of hypoxia and hyperventilation on outcome after paramedic rapid sequence intubation of severely head-injured patients
    • Davis D.P., Dunford J.V., Poste J.C., et al. The impact of hypoxia and hyperventilation on outcome after paramedic rapid sequence intubation of severely head-injured patients. J Trauma 57 (2004) 1-8
    • (2004) J Trauma , vol.57 , pp. 1-8
    • Davis, D.P.1    Dunford, J.V.2    Poste, J.C.3
  • 20
    • 0036581083 scopus 로고    scopus 로고
    • Succinylcholine improves the time of performance of a tracheal intubation in prehospital critical care medicine
    • Ricard-Hibon A., Chollet C., Leroy C., et al. Succinylcholine improves the time of performance of a tracheal intubation in prehospital critical care medicine. Eur J Anaesthesiol 19 (2002) 361-367
    • (2002) Eur J Anaesthesiol , vol.19 , pp. 361-367
    • Ricard-Hibon, A.1    Chollet, C.2    Leroy, C.3
  • 21
    • 0031305513 scopus 로고    scopus 로고
    • Tracheal intubation in prehospital resuscitation: importance of rapid-sequence induction anesthesia
    • Cantineau J.P., Tazarourte K., Merckx P., et al. Tracheal intubation in prehospital resuscitation: importance of rapid-sequence induction anesthesia. Ann Fr Anesth Reanim 16 (1997) 878-884
    • (1997) Ann Fr Anesth Reanim , vol.16 , pp. 878-884
    • Cantineau, J.P.1    Tazarourte, K.2    Merckx, P.3
  • 22
    • 4344564937 scopus 로고    scopus 로고
    • Evaluation of Frova, single-use intubation introducer, in a manikin. Comparison with Eschmann multiple-use introducer and Portex single-use introducer
    • Hodzovic I., Latto I.P., Wilkes A.R., et al. Evaluation of Frova, single-use intubation introducer, in a manikin. Comparison with Eschmann multiple-use introducer and Portex single-use introducer. Anaesthesia 59 (2004) 811-816
    • (2004) Anaesthesia , vol.59 , pp. 811-816
    • Hodzovic, I.1    Latto, I.P.2    Wilkes, A.R.3
  • 23
    • 0037240643 scopus 로고    scopus 로고
    • A comparison of simulated difficult intubation with multiple-use and single-use bougies in a manikin
    • Annamaneni R., Hodzovic I., Wilkes A.R., et al. A comparison of simulated difficult intubation with multiple-use and single-use bougies in a manikin. Anaesthesia 58 (2003) 45-49
    • (2003) Anaesthesia , vol.58 , pp. 45-49
    • Annamaneni, R.1    Hodzovic, I.2    Wilkes, A.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.