메뉴 건너뛰기




Volumn 40, Issue 2, 2007, Pages 369-386

Unsymmetrical tetradentate schiff bases copper (II) complex as neutral carrier for thiocyanate-selective electrode

Author keywords

Neutral carrier; O hydroxybenzophenone 12 diaminobenzene pyrrole 2 carbaldehyde; Thiocyanate selective electrodes; Unsymmetrical Schiff base

Indexed keywords


EID: 34547897098     PISSN: 00032719     EISSN: 1532236X     Source Type: Journal    
DOI: 10.1080/00032710600964742     Document Type: Article
Times cited : (31)

References (45)
  • 1
    • 0032701533 scopus 로고    scopus 로고
    • Thiocyanate-selective electrodes based on nickel and iron phthalocyanines
    • Amini, M.K., Shahrokhian, S., and Tangestaninejad, S. 1999. Thiocyanate-selective electrodes based on nickel and iron phthalocyanines. Anal. Chim. Acta, 402: 137-143.
    • (1999) Anal. Chim. Acta , vol.402 , pp. 137-143
    • Amini, M.K.1    Shahrokhian, S.2    Tangestaninejad, S.3
  • 2
    • 18844373372 scopus 로고    scopus 로고
    • Highly selective thiocyanate membrane electrode based on butane-2,3-dione- bis(salicylhydrazonato) zinc (II) complex
    • Ardakani, M.M., Sadeghi, A., and Salavati-Niasari, M. 2005. Highly selective thiocyanate membrane electrode based on butane-2,3-dione- bis(salicylhydrazonato) zinc (II) complex. Talanta, 66: 837-843.
    • (2005) Talanta , vol.66 , pp. 837-843
    • Ardakani, M.M.1    Sadeghi, A.2    Salavati-Niasari, M.3
  • 3
    • 33845379465 scopus 로고
    • Copper(II) and nickel(II) complexes of unsymmetrical tetradentate Schiff base ligands
    • Atkins, R., Brewer, G., Kokot, E., Mockler, G.M., and Sinn, E. 1985. Copper(II) and nickel(II) complexes of unsymmetrical tetradentate Schiff base ligands. Inorg. Chem., 24: 127-134.
    • (1985) Inorg. Chem , vol.24 , pp. 127-134
    • Atkins, R.1    Brewer, G.2    Kokot, E.3    Mockler, G.M.4    Sinn, E.5
  • 4
    • 0030128330 scopus 로고    scopus 로고
    • Determination of improved selectivity coefficients of polymer membrane ion-selective electrodes by conditioning with a discriminated ion
    • Bakker, E. 1996. Determination of improved selectivity coefficients of polymer membrane ion-selective electrodes by conditioning with a discriminated ion. J. Electrochemical Society, 143 (4): 83-85.
    • (1996) J. Electrochemical Society , vol.143 , Issue.4 , pp. 83-85
    • Bakker, E.1
  • 5
    • 0000854354 scopus 로고    scopus 로고
    • Determination of unbiased selectivity coefficients of neutral carrier-based cation-selective electrodes
    • Bakker, E. 1997. Determination of unbiased selectivity coefficients of neutral carrier-based cation-selective electrodes. Anal. Chem., 69: 1061-1069.
    • (1997) Anal. Chem , vol.69 , pp. 1061-1069
    • Bakker, E.1
  • 6
    • 0002232006 scopus 로고    scopus 로고
    • Selectivity of liquid membrane ion-selective electrodes
    • Bakker, E. 1997. Selectivity of liquid membrane ion-selective electrodes. Electroanalsis, 9: 7-12.
    • (1997) Electroanalsis , vol.9 , pp. 7-12
    • Bakker, E.1
  • 7
    • 0006375503 scopus 로고    scopus 로고
    • Hydrophobic membranes as liquid junction-free reference electrodes
    • Bakker, E. 1999. Hydrophobic membranes as liquid junction-free reference electrodes. Electroanalysis, 11: 788-792.
    • (1999) Electroanalysis , vol.11 , pp. 788-792
    • Bakker, E.1
  • 8
    • 4544366331 scopus 로고    scopus 로고
    • Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics
    • Bakker, E., Bühlmann, P., and Pretsch, E. 1997. Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics. Chem. Rev., 97 (8): 3083-3132.
    • (1997) Chem. Rev , vol.97 , Issue.8 , pp. 3083-3132
    • Bakker, E.1    Bühlmann, P.2    Pretsch, E.3
  • 9
    • 0000020499 scopus 로고
    • Anion-selective membrane electrodes based on metalloporphyrins: The influence of lipophilic anionic and cationic sites on potentiometric selectivity
    • Bakker, E., Malinowska, E., Schiller, R.D., and Meyerhoff, M.E. 1994. Anion-selective membrane electrodes based on metalloporphyrins: the influence of lipophilic anionic and cationic sites on potentiometric selectivity. Talanta, 41 (6): 881-890.
    • (1994) Talanta , vol.41 , Issue.6 , pp. 881-890
    • Bakker, E.1    Malinowska, E.2    Schiller, R.D.3    Meyerhoff, M.E.4
  • 10
    • 0034653614 scopus 로고    scopus 로고
    • Selectivity of potentiometric ion sensors
    • Bakker, E., Pretsch, E., and Bühlmann, P. 2000. Selectivity of potentiometric ion sensors. Anal. Chem., 72 (6): 1127-1133.
    • (2000) Anal. Chem , vol.72 , Issue.6 , pp. 1127-1133
    • Bakker, E.1    Pretsch, E.2    Bühlmann, P.3
  • 11
    • 0032099044 scopus 로고    scopus 로고
    • Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors
    • Bühlmann, P., Pretsch, E., and Bakker, E. 1998. Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors. Chem. Rev., 98: 1593-1687.
    • (1998) Chem. Rev , vol.98 , pp. 1593-1687
    • Bühlmann, P.1    Pretsch, E.2    Bakker, E.3
  • 12
    • 4544227316 scopus 로고    scopus 로고
    • Ion-selective electrodes for thiocyanate based on the dinuclear zinc(ii) complex of a bis-N,O-bidentate Schiff base
    • Bühlmann, P., Yahya, L., and Enderes, R. 2004. Ion-selective electrodes for thiocyanate based on the dinuclear zinc(ii) complex of a bis-N,O-bidentate Schiff base. Electroanalysis, 16 (12): 973-978.
    • (2004) Electroanalysis , vol.16 , Issue.12 , pp. 973-978
    • Bühlmann, P.1    Yahya, L.2    Enderes, R.3
  • 13
    • 0024286599 scopus 로고
    • Influence of porphyrin structure on anion selectivities of manganese(III) porphyrin based membrane electrodes
    • Chaniotakis, N.A., Chasser, A.M., Meyerhoff, M.E., and Groves, J.T. 1988. Influence of porphyrin structure on anion selectivities of manganese(III) porphyrin based membrane electrodes. Anal. Chem., 60 (2): 185-188.
    • (1988) Anal. Chem , vol.60 , Issue.2 , pp. 185-188
    • Chaniotakis, N.A.1    Chasser, A.M.2    Meyerhoff, M.E.3    Groves, J.T.4
  • 14
    • 0024515446 scopus 로고
    • Salicylate-selective membrane electrode based on tin(IV)-tetraphenylporphyrin
    • Chaniotakis, N.A., Park, S.B., and Meyerhoff, M.E. 1989. Salicylate-selective membrane electrode based on tin(IV)-tetraphenylporphyrin. Anal. Chem., 61 (6): 566-570.
    • (1989) Anal. Chem , vol.61 , Issue.6 , pp. 566-570
    • Chaniotakis, N.A.1    Park, S.B.2    Meyerhoff, M.E.3
  • 16
    • 0000530842 scopus 로고
    • Anion-selective electrodes based on electropolymerized porphyrin films
    • Daunert, S., Wallace, S., Flurido, A., and Bachas, L.G. 1991. Anion-selective electrodes based on electropolymerized porphyrin films. Anal. Chem., 63 (17): 1676-1679.
    • (1991) Anal. Chem , vol.63 , Issue.17 , pp. 1676-1679
    • Daunert, S.1    Wallace, S.2    Flurido, A.3    Bachas, L.G.4
  • 17
    • 0001377914 scopus 로고
    • Selectivity-modifying influence of anionic sites in neutral-carrier-based membrane electrodes
    • Eugster, R., Gehring, P.M., Morf, W.E., Spichiger, U., and Simon, W. 1991. Selectivity-modifying influence of anionic sites in neutral-carrier-based membrane electrodes. Anal. Chem., 63: 2285-2289.
    • (1991) Anal. Chem , vol.63 , pp. 2285-2289
    • Eugster, R.1    Gehring, P.M.2    Morf, W.E.3    Spichiger, U.4    Simon, W.5
  • 19
    • 0035724954 scopus 로고    scopus 로고
    • Higly selective thiocyanate poly (vinyl chloride) membrane electrode based on a cadmium-Schiff's base complex fresenius
    • Ganjali, M.R., Poursaberi, T., Basiripour, F., Salavati-Niassari, M., Yousefi, M., and Shamsipur, M. 2001. Higly selective thiocyanate poly (vinyl chloride) membrane electrode based on a cadmium-Schiff's base complex fresenius. J. Anal. Chem., 370: 1091-1095.
    • (2001) J. Anal. Chem , vol.370 , pp. 1091-1095
    • Ganjali, M.R.1    Poursaberi, T.2    Basiripour, F.3    Salavati-Niassari, M.4    Yousefi, M.5    Shamsipur, M.6
  • 20
    • 0000461733 scopus 로고
    • Metallopophyrin derivatives as neutral carriers for membrane eletrodes
    • Gao, D., Li, J.Z., and Yu, R.Q. 1994. Metallopophyrin derivatives as neutral carriers for membrane eletrodes. Anal. Chem., 66: 2245-2249.
    • (1994) Anal. Chem , vol.66 , pp. 2245-2249
    • Gao, D.1    Li, J.Z.2    Yu, R.Q.3
  • 21
    • 0002075784 scopus 로고
    • Thiocyanate solvent polymeric membrane ion-selective electrode based on cobalt(III) α,β,γ,δ- tetraphenylporphyrin anion carrier
    • Hodina, A. and Jyo, A. 1988. Thiocyanate solvent polymeric membrane ion-selective electrode based on cobalt(III) α,β,γ,δ- tetraphenylporphyrin anion carrier. Chem. Lett., 6: 993-996.
    • (1988) Chem. Lett , vol.6 , pp. 993-996
    • Hodina, A.1    Jyo, A.2
  • 23
    • 0000930819 scopus 로고
    • Transport properties of anion-selective membranes based on cobyrinates and metalloporphyrin complexes as ionophores
    • Huser, M., Morf, W.E., Fluri, K., Seiler, K., Schulthess, P., and Simon, W. 1990. Transport properties of anion-selective membranes based on cobyrinates and metalloporphyrin complexes as ionophores. Helv. Chim. Acta, 73 (5): 1481-1496.
    • (1990) Helv. Chim. Acta , vol.73 , Issue.5 , pp. 1481-1496
    • Huser, M.1    Morf, W.E.2    Fluri, K.3    Seiler, K.4    Schulthess, P.5    Simon, W.6
  • 24
    • 0001752478 scopus 로고
    • Nitrate-selective electrode developed by electrochemically mediated imprinting/poping of polypyrrole
    • Hutchins, R.S. and Bachas, L.G. 1995. Nitrate-selective electrode developed by electrochemically mediated imprinting/poping of polypyrrole. Anal. Chem., 6: 1654-1660.
    • (1995) Anal. Chem , vol.6 , pp. 1654-1660
    • Hutchins, R.S.1    Bachas, L.G.2
  • 25
    • 0032586093 scopus 로고    scopus 로고
    • Thiocyanate - selective PVC membrane electrodes based on Mn(II) complex of N,N′-bis-(4- phenylazosalicylidene) o-phenylenediamine as a neutral carrier
    • Li, Z.Q., Wu, Z.Y., Yuan, R., Ying, M., Shen, G.L., and Yu, R.Q. 1999. Thiocyanate - selective PVC membrane electrodes based on Mn(II) complex of N,N′-bis-(4- phenylazosalicylidene) o-phenylenediamine as a neutral carrier. Electrochimica Acta., 44: 2543-2548.
    • (1999) Electrochimica Acta , vol.44 , pp. 2543-2548
    • Li, Z.Q.1    Wu, Z.Y.2    Yuan, R.3    Ying, M.4    Shen, G.L.5    Yu, R.Q.6
  • 26
    • 0043064001 scopus 로고    scopus 로고
    • Improving the detection limit of anion-selective electrodes: An iodide-selective membrane with a nanomolar detection limit
    • Malon, A., Radu, A., Qin, W., Qin, Y., Ceresa, A., Zurawska, M.M., Bakker, E., and Pretsch, E. 2003. Improving the detection limit of anion-selective electrodes: An iodide-selective membrane with a nanomolar detection limit. Anal. Chem., 75 (15): 3865-3871.
    • (2003) Anal. Chem , vol.75 , Issue.15 , pp. 3865-3871
    • Malon, A.1    Radu, A.2    Qin, W.3    Qin, Y.4    Ceresa, A.5    Zurawska, M.M.6    Bakker, E.7    Pretsch, E.8
  • 27
    • 0542435486 scopus 로고
    • Evaluation of the optimum composition of neutral-carrier membrane electrodes with incorporated cation-exchanger sites
    • Meier, P.C., Morf, W.E., Läubli, M., and Simon, W. 1984. Evaluation of the optimum composition of neutral-carrier membrane electrodes with incorporated cation-exchanger sites. Anal. Chim. Acta, 156: 1-8.
    • (1984) Anal. Chim. Acta , vol.156 , pp. 1-8
    • Meier, P.C.1    Morf, W.E.2    Läubli, M.3    Simon, W.4
  • 28
    • 0032883892 scopus 로고    scopus 로고
    • Detection limit of polymeric membrane potentiometric ion sensors: How can we go down to trace levels?
    • Mi, Y., Mathison, S., Goines, R., Logue, A., and Bakker, E. 1999. Detection limit of polymeric membrane potentiometric ion sensors: how can we go down to trace levels? Anal. Chim. Acta, 397 (1-3): 103-111.
    • (1999) Anal. Chim. Acta , vol.397 , Issue.1-3 , pp. 103-111
    • Mi, Y.1    Mathison, S.2    Goines, R.3    Logue, A.4    Bakker, E.5
  • 29
    • 0346122951 scopus 로고    scopus 로고
    • Rotating disk potentiometry for inner solution optimization of low-detection-limit ion-selective electrodes
    • Radu, A., Telting-Diaz, M., Bakker, E., and Eric, E. 2003. Rotating disk potentiometry for inner solution optimization of low-detection-limit ion-selective electrodes. Anal. Chem., 75 (24): 6922-6931.
    • (2003) Anal. Chem , vol.75 , Issue.24 , pp. 6922-6931
    • Radu, A.1    Telting-Diaz, M.2    Bakker, E.3    Eric, E.4
  • 30
    • 0027391147 scopus 로고
    • Chloride-selective electrodes based on mercury organic compounds as neutral carriers
    • Rothmaier, M. and Simon, W. 1993. Chloride-selective electrodes based on mercury organic compounds as neutral carriers. Anal. Chim. Acta., 271: 135-141.
    • (1993) Anal. Chim. Acta , vol.271 , pp. 135-141
    • Rothmaier, M.1    Simon, W.2
  • 31
    • 0001738932 scopus 로고
    • Ionic additives for ionselective electrodes based on electrically charged carriers
    • Schaller, U., Bakker, E., Spichiger, U.E., and Pretsch, E. 1994. Ionic additives for ionselective electrodes based on electrically charged carriers. Anal. Chem., 66 (3): 391-398.
    • (1994) Anal. Chem , vol.66 , Issue.3 , pp. 391-398
    • Schaller, U.1    Bakker, E.2    Spichiger, U.E.3    Pretsch, E.4
  • 33
    • 0037099232 scopus 로고    scopus 로고
    • Chromium(III) porphyrin as a selective ionophore in a salicylate-selective membrane electrode
    • Shahrokhian, S., Hamzehloei, A., and Bagherzadeh, M. 2002. Chromium(III) porphyrin as a selective ionophore in a salicylate-selective membrane electrode. Anal. Chem., 74: 3312-3320.
    • (2002) Anal. Chem , vol.74 , pp. 3312-3320
    • Shahrokhian, S.1    Hamzehloei, A.2    Bagherzadeh, M.3
  • 34
    • 12844249438 scopus 로고    scopus 로고
    • The first use of a Rh(III) complex as a novel ionophore for thiocyanate-selective polymeric membrane electrodes
    • Shamsipur, M., Ershad, S., Samadi, N., Rezvani, A.R., and Haddadzadeh, H. 2005. The first use of a Rh(III) complex as a novel ionophore for thiocyanate-selective polymeric membrane electrodes. Talanta, 65: 991-997.
    • (2005) Talanta , vol.65 , pp. 991-997
    • Shamsipur, M.1    Ershad, S.2    Samadi, N.3    Rezvani, A.R.4    Haddadzadeh, H.5
  • 35
    • 0001006899 scopus 로고    scopus 로고
    • Thiocyanate-selective membrane electrode based on (octabromotetraphenylporphyrinato) manganese(III) chloride
    • Shamsipur, M., Khayatian, G., and Tangestaninejad, S. 1999. Thiocyanate-selective membrane electrode based on (octabromotetraphenylporphyrinato) manganese(III) chloride. Electroanalysis, 11 (18): 1340-1344.
    • (1999) Electroanalysis , vol.11 , Issue.18 , pp. 1340-1344
    • Shamsipur, M.1    Khayatian, G.2    Tangestaninejad, S.3
  • 37
    • 0000609475 scopus 로고
    • Liquid ion-exchange membranes of extreme selectivity and high permeability for anions
    • Sollner, K. and Shean, G.M. 1964. Liquid ion-exchange membranes of extreme selectivity and high permeability for anions. J. Am. Chem. Soc., 86 (9): 1901-1902.
    • (1964) J. Am. Chem. Soc , vol.86 , Issue.9 , pp. 1901-1902
    • Sollner, K.1    Shean, G.M.2
  • 38
    • 0034536110 scopus 로고    scopus 로고
    • Origin of non-Nernstian anion response slopes of metalloporphyrin-based liquid/polymer membrane electrodes
    • Steinle, E.D., Amemiya, S., Bühlmann, P., and Meyerhoff, M.E. 2000. Origin of non-Nernstian anion response slopes of metalloporphyrin-based liquid/polymer membrane electrodes. Anal. Chem., 72 (23): 5766-5773.
    • (2000) Anal. Chem , vol.72 , Issue.23 , pp. 5766-5773
    • Steinle, E.D.1    Amemiya, S.2    Bühlmann, P.3    Meyerhoff, M.E.4
  • 39
    • 0032386953 scopus 로고    scopus 로고
    • Response characteristics of anion-selective polymer membrane electrodes based on gallium(III), indium(III) and thallium(III) porphyrin
    • Steinle, E.D., Schaller, U., and Meyerhoff, M.E. 1998. Response characteristics of anion-selective polymer membrane electrodes based on gallium(III), indium(III) and thallium(III) porphyrin. Analytical Sciences, 14 (1): 79-84.
    • (1998) Analytical Sciences , vol.14 , Issue.1 , pp. 79-84
    • Steinle, E.D.1    Schaller, U.2    Meyerhoff, M.E.3
  • 40
    • 0001337219 scopus 로고
    • Aquocyanocobalt(III)-hepta(2-phenylethyl)-cobyrinate as a cationic carrier for nitrite-selective liquid-membrane electrodes
    • Stepanek, R., Krautler, B., Schulthess, P., Lindemann, B., Ammann, D., and Simon, W. 1986. Aquocyanocobalt(III)-hepta(2-phenylethyl)-cobyrinate as a cationic carrier for nitrite-selective liquid-membrane electrodes. Anal. Chim. Acta, 182: 83-90.
    • (1986) Anal. Chim. Acta , vol.182 , pp. 83-90
    • Stepanek, R.1    Krautler, B.2    Schulthess, P.3    Lindemann, B.4    Ammann, D.5    Simon, W.6
  • 41
    • 3042789594 scopus 로고    scopus 로고
    • Study of a bis-furaldehyde Schiff base copper(II) complex as carrier for preparation of highly selective thiocyanate electrodes
    • Sun, Z.Y., Yuan, R., Chai, Y.Q., and Xu, L. 2004. Study of a bis-furaldehyde Schiff base copper(II) complex as carrier for preparation of highly selective thiocyanate electrodes. Anal. Bioanal. Chem., 378: 490-494.
    • (2004) Anal. Bioanal. Chem , vol.378 , pp. 490-494
    • Sun, Z.Y.1    Yuan, R.2    Chai, Y.Q.3    Xu, L.4
  • 44
    • 0027682558 scopus 로고
    • Schiff base complexes of cobalt(II) as neutral carriers for highly selective iodide electrodes
    • Yuan, R., Chai, Y.Q., Liu, D., Gao, D., Li, J.Z., and Yu, R.Q. 1993. Schiff base complexes of cobalt(II) as neutral carriers for highly selective iodide electrodes. Anal. Chem., 65 (19): 2572-2575.
    • (1993) Anal. Chem , vol.65 , Issue.19 , pp. 2572-2575
    • Yuan, R.1    Chai, Y.Q.2    Liu, D.3    Gao, D.4    Li, J.Z.5    Yu, R.Q.6
  • 45
    • 0042129891 scopus 로고    scopus 로고
    • Highly selective thiocyanate electrode based on bis-bebzoin - semitriethylenetetraamine binuclear copper(II) complex as neutral carrier
    • Yuan, R., Wang, X.L., and Chai, Y.Q. 2003. Highly selective thiocyanate electrode based on bis-bebzoin - semitriethylenetetraamine binuclear copper(II) complex as neutral carrier. Electrochem. Commun., 5: 717-721.
    • (2003) Electrochem. Commun , vol.5 , pp. 717-721
    • Yuan, R.1    Wang, X.L.2    Chai, Y.Q.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.