메뉴 건너뛰기




Volumn 85, Issue 5, 2007, Pages 249-255

A new mechatronic assistance system for the neurosurgical operating theatre: Implementation, assessment of accuracy and application concepts

Author keywords

Frameless stereotaxy, accuracy; Neurosurgery; Robotics

Indexed keywords

ARTICLE; CADAVER; COMPUTER; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER PROGRAM; ENDOSCOPY; HEAD; MECHATRONIC ASSISTANCE SYSTEM; NEUROSURGERY; OPERATING ROOM; REPRODUCIBILITY; ROBOTICS; STEREOTAXIC SURGERY; SURGICAL EQUIPMENT;

EID: 34547874285     PISSN: 10116125     EISSN: None     Source Type: Journal    
DOI: 10.1159/000103264     Document Type: Article
Times cited : (8)

References (21)
  • 3
    • 0031719836 scopus 로고    scopus 로고
    • Primary and revision total hip replacement using the Robodoc system
    • Bargar WL, Bauer A, Borner M: Primary and revision total hip replacement using the Robodoc system. Clin Orthop 1998;354:82-91.
    • (1998) Clin Orthop , vol.354 , pp. 82-91
    • Bargar, W.L.1    Bauer, A.2    Borner, M.3
  • 4
    • 0032125859 scopus 로고    scopus 로고
    • Remote operative urology using a surgical telemanipulatory system: Preliminary observations
    • Bowersox JC, Cornum RL: Remote operative urology using a surgical telemanipulatory system: preliminary observations. Urology 1998;52:17-22.
    • (1998) Urology , vol.52 , pp. 17-22
    • Bowersox, J.C.1    Cornum, R.L.2
  • 6
    • 0031657634 scopus 로고    scopus 로고
    • Manual versus robotically assisted laparoscopic surgery in the performance of basic manipulation and suturing tasks
    • Garcia-Ruiz A, Gagner M, Miller JH, Steiner CP, Hahn JF: Manual versus robotically assisted laparoscopic surgery in the performance of basic manipulation and suturing tasks. Arch Surg 1998;133:957-961.
    • (1998) Arch Surg , vol.133 , pp. 957-961
    • Garcia-Ruiz, A.1    Gagner, M.2    Miller, J.H.3    Steiner, C.P.4    Hahn, J.F.5
  • 8
    • 3042671992 scopus 로고    scopus 로고
    • Robotic surgery in otorhinolaryngology
    • Federspil PA, Plinkert PK: Robotic surgery in otorhinolaryngology. Otolaryngol Pol 2004;58:237-242.
    • (2004) Otolaryngol Pol , vol.58 , pp. 237-242
    • Federspil, P.A.1    Plinkert, P.K.2
  • 11
    • 2442489885 scopus 로고    scopus 로고
    • Adaptation of a hexapod-based robotic system for extended endoscope-assisted transsphenoidal skull base surgery
    • Nimsky C, Rachinger J, Iro H, Fahlbusch R: Adaptation of a hexapod-based robotic system for extended endoscope-assisted transsphenoidal skull base surgery. Minim Invas Neurosurg 2004;47:41-46.
    • (2004) Minim Invas Neurosurg , vol.47 , pp. 41-46
    • Nimsky, C.1    Rachinger, J.2    Iro, H.3    Fahlbusch, R.4
  • 16
    • 23144436643 scopus 로고    scopus 로고
    • An automated robotic approach with redundant navigation for minimal invasive extended transsphenoidal skull base surgery
    • Bumm K, Wurm J, Rachinger J, Dannenmann T, Bohr C, Fahlbusch R, Iro H, Nimsky C: An automated robotic approach with redundant navigation for minimal invasive extended transsphenoidal skull base surgery. Minim Invas Neurosurg 2005;48:159-164.
    • (2005) Minim Invas Neurosurg , vol.48 , pp. 159-164
    • Bumm, K.1    Wurm, J.2    Rachinger, J.3    Dannenmann, T.4    Bohr, C.5    Fahlbusch, R.6    Iro, H.7    Nimsky, C.8
  • 19
    • 0026620814 scopus 로고
    • Accuracy of pedicle screws following instrumented dorsal fusion of the lumbar spine (in German)
    • Jerosch J, Malms J, Castro WH, Wagner R, Wiesner L: Accuracy of pedicle screws following instrumented dorsal fusion of the lumbar spine (in German). Z Orthop Ihre Grenzgeb 1992;130:479-483.
    • (1992) Z Orthop Ihre Grenzgeb , vol.130 , pp. 479-483
    • Jerosch, J.1    Malms, J.2    Castro, W.H.3    Wagner, R.4    Wiesner, L.5
  • 20
    • 0033834616 scopus 로고    scopus 로고
    • Accuracy of pedicle screw insertion with and without computer assistance: A randomised controlled clinical study in 100 consecutive patients
    • Laine T, Lund T, Ylikowski M, Lohikoski J, Schlenzka D: Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J 2000;9:235-240.
    • (2000) Eur Spine J , vol.9 , pp. 235-240
    • Laine, T.1    Lund, T.2    Ylikowski, M.3    Lohikoski, J.4    Schlenzka, D.5
  • 21
    • 0034061781 scopus 로고    scopus 로고
    • Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine
    • Amiot LP, Lang K, Putzier M, Zippel H, Labelle H: Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine 2000;25:606-614.
    • (2000) Spine , vol.25 , pp. 606-614
    • Amiot, L.P.1    Lang, K.2    Putzier, M.3    Zippel, H.4    Labelle, H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.