메뉴 건너뛰기




Volumn 26, Issue 2, 2007, Pages 279-287

Cardiac MRI in mice at 9.4 tesla with a transmit-receive surface coil and a cardiac-tailored intensity-correction algorithm

Author keywords

Cardiac; Magnetic resonance imaging; Mouse; Sensitivity correction; Surface coil

Indexed keywords

ALGORITHM; ANIMAL CELL; ANIMAL EXPERIMENT; ANIMAL MODEL; ANIMAL TISSUE; ARTICLE; ARTIFACT REDUCTION; CARDIAC MAGNETIC RESONANCE IMAGING; CONTRAST ENHANCEMENT; CONTROLLED STUDY; CORONARY ARTERY; DANTE SEQUENCE; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; FLOW MEASUREMENT; HEART VALVE; IMAGE INTENSIFIER; IMAGE QUALITY; INTENSITY CORRECTION ALGORITHM; MOUSE; NOISE REDUCTION; NONHUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; TECHNOLOGY; TRABECULOTOMY; TRANSMIT RECEIVE SURFACE COIL TECHNOLOGY;

EID: 34547867375     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.20966     Document Type: Article
Times cited : (18)

References (22)
  • 1
    • 0034293153 scopus 로고    scopus 로고
    • Magnetic resonance imaging of coronary arteries and heart valves in a living mouse: Techniques and preliminary results
    • Ruff J, Wiesmann F, Lanz T, Haase A. Magnetic resonance imaging of coronary arteries and heart valves in a living mouse: techniques and preliminary results. J Magn Reson 2000;146:290-296.
    • (2000) J Magn Reson , vol.146 , pp. 290-296
    • Ruff, J.1    Wiesmann, F.2    Lanz, T.3    Haase, A.4
  • 2
    • 0035970614 scopus 로고    scopus 로고
    • Dobutamine-stress magnetic resonance microimaging in mice: Acute changes of cardiac geometry and function in normal and failing murine hearts
    • Wiesmann F, Ruff J, Engelhardt S, et al. Dobutamine-stress magnetic resonance microimaging in mice: acute changes of cardiac geometry and function in normal and failing murine hearts. Circ Res 2001;88:563-569.
    • (2001) Circ Res , vol.88 , pp. 563-569
    • Wiesmann, F.1    Ruff, J.2    Engelhardt, S.3
  • 3
    • 12244249203 scopus 로고    scopus 로고
    • Characterization of aortic root atherosclerosis in ApoE knockout mice: High-resolution in vivo and ex vivo MRM with histological correlation
    • Itskovich VV, Choudhury RP, Aguinaldo JG, et al. Characterization of aortic root atherosclerosis in ApoE knockout mice: high-resolution in vivo and ex vivo MRM with histological correlation. Magn Reson Med 2003;49:381-385.
    • (2003) Magn Reson Med , vol.49 , pp. 381-385
    • Itskovich, V.V.1    Choudhury, R.P.2    Aguinaldo, J.G.3
  • 4
    • 0036325934 scopus 로고    scopus 로고
    • MR tagging early after myocardial infarction in mice demonstrates contractile dysfunction in adjacent and remote regions
    • Epstein FH, Yang Z, Gilson WD, Berr SS, Kramer CM, French BA. MR tagging early after myocardial infarction in mice demonstrates contractile dysfunction in adjacent and remote regions. Magn Reson Med 2002;48:399-403.
    • (2002) Magn Reson Med , vol.48 , pp. 399-403
    • Epstein, F.H.1    Yang, Z.2    Gilson, W.D.3    Berr, S.S.4    Kramer, C.M.5    French, B.A.6
  • 6
    • 14744290653 scopus 로고    scopus 로고
    • In vivo assessment of absolute perfusion and intracapillary blood volume in the murine myocardium by spin labeling magnetic resonance imaging
    • Streif JU, Nahrendorf M, Hiller KH, et al. In vivo assessment of absolute perfusion and intracapillary blood volume in the murine myocardium by spin labeling magnetic resonance imaging. Magn Reson Med 2005;53:584-592.
    • (2005) Magn Reson Med , vol.53 , pp. 584-592
    • Streif, J.U.1    Nahrendorf, M.2    Hiller, K.H.3
  • 8
  • 9
    • 0029147415 scopus 로고
    • Phased array detectors and an automated intensity-correction algorithm for high-resolution MR imaging of the human brain
    • Wald LL, Carvajal L, Moyher SE, et al. Phased array detectors and an automated intensity-correction algorithm for high-resolution MR imaging of the human brain. Magn Reson Med 1995;34:433-439.
    • (1995) Magn Reson Med , vol.34 , pp. 433-439
    • Wald, L.L.1    Carvajal, L.2    Moyher, S.E.3
  • 10
    • 0029972766 scopus 로고    scopus 로고
    • Intensity correction of phased-array surface coil images
    • Murakami JW, Hayes CE, Weinberger E. Intensity correction of phased-array surface coil images. Magn Reson Med 1996;35:585-590.
    • (1996) Magn Reson Med , vol.35 , pp. 585-590
    • Murakami, J.W.1    Hayes, C.E.2    Weinberger, E.3
  • 11
    • 0034763204 scopus 로고    scopus 로고
    • Improved high resolution MR imaging for surface coils using automated intensity non-uniformity correction: Feasibility study in the orbit
    • Vokurka EA, Watson NA, Watson Y, Thacker NA, Jackson A. Improved high resolution MR imaging for surface coils using automated intensity non-uniformity correction: feasibility study in the orbit. J Magn Reson Imaging 2001;14:540-546.
    • (2001) J Magn Reson Imaging , vol.14 , pp. 540-546
    • Vokurka, E.A.1    Watson, N.A.2    Watson, Y.3    Thacker, N.A.4    Jackson, A.5
  • 12
    • 28444487453 scopus 로고    scopus 로고
    • Combination of optimized transmit arrays and some receive array reconstruction methods can yield homogeneous images at very high frequencies
    • Collins CM, Liu W, Swift BJ, Smith MB. Combination of optimized transmit arrays and some receive array reconstruction methods can yield homogeneous images at very high frequencies. Magn Reson Med 2005;54:1327-1332.
    • (2005) Magn Reson Med , vol.54 , pp. 1327-1332
    • Collins, C.M.1    Liu, W.2    Swift, B.J.3    Smith, M.B.4
  • 13
    • 22744434112 scopus 로고    scopus 로고
    • Transceive surface coil array for magnetic resonance imaging of the human brain at 4 T
    • Pinkerton RG, Barberi EA, Menon RS. Transceive surface coil array for magnetic resonance imaging of the human brain at 4 T. Magn Reson Med 2005;54:499-503.
    • (2005) Magn Reson Med , vol.54 , pp. 499-503
    • Pinkerton, R.G.1    Barberi, E.A.2    Menon, R.S.3
  • 14
    • 12844266240 scopus 로고    scopus 로고
    • Measurement and correction of transmitter and receiver induced nonuniformities in vivo
    • Wang J, Qiu M, Yang QX, Smith MB, Constable RT. Measurement and correction of transmitter and receiver induced nonuniformities in vivo. Magn Reson Med 2005;53:408-417.
    • (2005) Magn Reson Med , vol.53 , pp. 408-417
    • Wang, J.1    Qiu, M.2    Yang, Q.X.3    Smith, M.B.4    Constable, R.T.5
  • 15
    • 1542514708 scopus 로고    scopus 로고
    • Simultaneous evaluation of infarct size and cardiac function in intact mice by contrast-enhanced cardiac magnetic resonance imaging reveals contractile dysfunction in noninfarcted regions early after myocardial infarction
    • Yang Z, Berr SS, Gilson WD, Toufektsian MC, French BA. Simultaneous evaluation of infarct size and cardiac function in intact mice by contrast-enhanced cardiac magnetic resonance imaging reveals contractile dysfunction in noninfarcted regions early after myocardial infarction. Circulation 2004;109:1161-1167.
    • (2004) Circulation , vol.109 , pp. 1161-1167
    • Yang, Z.1    Berr, S.S.2    Gilson, W.D.3    Toufektsian, M.C.4    French, B.A.5
  • 16
    • 33744899046 scopus 로고    scopus 로고
    • Multimodal functional cardiac MR imaging in creatine kinase deficient mice reveals subtle abnormalities in myocardial perfusion and mechanics
    • Nahrendorf M, Streif JU, Hiller KH, et al. Multimodal functional cardiac MR imaging in creatine kinase deficient mice reveals subtle abnormalities in myocardial perfusion and mechanics. Am J Physiol Heart Circ Physiol 2006;290:H2516-2521.
    • (2006) Am J Physiol Heart Circ Physiol , vol.290
    • Nahrendorf, M.1    Streif, J.U.2    Hiller, K.H.3
  • 17
    • 0037382475 scopus 로고    scopus 로고
    • Assessment of global and regional myocardial function in the mouse using cine and tagged MRI
    • Zhou R, Pickup S, Glickson JD, Scott CH, Ferrari VA. Assessment of global and regional myocardial function in the mouse using cine and tagged MRI. Magn Reson Med 2003;49:760-764.
    • (2003) Magn Reson Med , vol.49 , pp. 760-764
    • Zhou, R.1    Pickup, S.2    Glickson, J.D.3    Scott, C.H.4    Ferrari, V.A.5
  • 18
    • 14044262286 scopus 로고    scopus 로고
    • Distinct mouse coronary anatomy and myocardial infarction consequent to ligation
    • Kumar D, Hacker TA, Buck J, et al. Distinct mouse coronary anatomy and myocardial infarction consequent to ligation. Coronary Artery Dis 2005;16:41-44.
    • (2005) Coronary Artery Dis , vol.16 , pp. 41-44
    • Kumar, D.1    Hacker, T.A.2    Buck, J.3
  • 20
    • 24144479486 scopus 로고    scopus 로고
    • Magnetic resonance imaging of cardiomyocyte apoptosis with a novel magneto-optical nanoparticle
    • Sosnovik DE, Schellenberger EA, Nahrendorf M, et al. Magnetic resonance imaging of cardiomyocyte apoptosis with a novel magneto-optical nanoparticle. Magn Reson Med 2005;54:718-724.
    • (2005) Magn Reson Med , vol.54 , pp. 718-724
    • Sosnovik, D.E.1    Schellenberger, E.A.2    Nahrendorf, M.3
  • 21
    • 0035112409 scopus 로고    scopus 로고
    • A multi-scale method for automatic correction of intensity non-uniformity in MR images
    • Han C, Hatsukami TS, Yuan C. A multi-scale method for automatic correction of intensity non-uniformity in MR images. J Magn Reson Imaging 2001;13:428-436.
    • (2001) J Magn Reson Imaging , vol.13 , pp. 428-436
    • Han, C.1    Hatsukami, T.S.2    Yuan, C.3
  • 22
    • 0037904043 scopus 로고    scopus 로고
    • A wavelet-based approximation of surface coil sensitivity profiles for correction of image intensity inhomogeneity and parallel imaging reconstruction
    • Lin FH, Chen YJ, Belliveau JW, Wald LL. A wavelet-based approximation of surface coil sensitivity profiles for correction of image intensity inhomogeneity and parallel imaging reconstruction. Hum Brain Mapp 2003;19:96-111.
    • (2003) Hum Brain Mapp , vol.19 , pp. 96-111
    • Lin, F.H.1    Chen, Y.J.2    Belliveau, J.W.3    Wald, L.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.