메뉴 건너뛰기




Volumn 24, Issue 10, 2006, Pages 1303-1310

Artifact-free black-blood cine cardiac imaging in a single breath-hold

Author keywords

Black blood; STEAM; Stimulated echo

Indexed keywords

GADOLINIUM PENTETATE;

EID: 34547818516     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.mri.2006.08.008     Document Type: Article
Times cited : (7)

References (8)
  • 1
    • 0022534594 scopus 로고
    • MR imaging using stimulated echoes (STEAM)
    • Haase A., Frahm J., Matthaei D., et al. MR imaging using stimulated echoes (STEAM). Radiology 160 (1986) 787-790
    • (1986) Radiology , vol.160 , pp. 787-790
    • Haase, A.1    Frahm, J.2    Matthaei, D.3
  • 3
    • 0026526819 scopus 로고
    • Diffusion imaging of the human brain in vivo using high-speed STEAM MRI
    • Merboldt K.D., Hanicke W., Bruhn H., Gyngell M.L., and Frahm J. Diffusion imaging of the human brain in vivo using high-speed STEAM MRI. Magn Reson Med 23 (1992) 179-192
    • (1992) Magn Reson Med , vol.23 , pp. 179-192
    • Merboldt, K.D.1    Hanicke, W.2    Bruhn, H.3    Gyngell, M.L.4    Frahm, J.5
  • 4
    • 0033093565 scopus 로고    scopus 로고
    • DENSE: displacement encoding with stimulated echoes in cardiac functional MRI
    • Aletras A.H., Ding S., Balaban R.S., and Wen H. DENSE: displacement encoding with stimulated echoes in cardiac functional MRI. J Magn Reson 137 (1999) 247-252
    • (1999) J Magn Reson , vol.137 , pp. 247-252
    • Aletras, A.H.1    Ding, S.2    Balaban, R.S.3    Wen, H.4
  • 5
    • 0022497660 scopus 로고
    • Multiple chemical shift selective (CHESS) MR imaging using stimulated echoes
    • Matthaei D., Haase A., Frahm J., Bomsdorf H., and Vollmann W. Multiple chemical shift selective (CHESS) MR imaging using stimulated echoes. Radiology 160 (1986) 791-794
    • (1986) Radiology , vol.160 , pp. 791-794
    • Matthaei, D.1    Haase, A.2    Frahm, J.3    Bomsdorf, H.4    Vollmann, W.5
  • 6
    • 0029040249 scopus 로고
    • Limitations of STimulated Echo Acquisition Mode (STEAM) techniques in cardiac applications
    • Fischer S.E., Stuber M., Scheidegger M.B., and Boesiger P. Limitations of STimulated Echo Acquisition Mode (STEAM) techniques in cardiac applications. Magn Reson Med 34 (1995) 80-91
    • (1995) Magn Reson Med , vol.34 , pp. 80-91
    • Fischer, S.E.1    Stuber, M.2    Scheidegger, M.B.3    Boesiger, P.4
  • 7
    • 32544431553 scopus 로고    scopus 로고
    • Correction of through-plane deformation artifacts in STimulated Echo Acquisition Mode cardiac imaging
    • Fahmy A.S., Li P., Stuber M., and Osman N.F. Correction of through-plane deformation artifacts in STimulated Echo Acquisition Mode cardiac imaging. Magn Reson Med 55 (2006) 404-412
    • (2006) Magn Reson Med , vol.55 , pp. 404-412
    • Fahmy, A.S.1    Li, P.2    Stuber, M.3    Osman, N.F.4
  • 8
    • 0034909497 scopus 로고    scopus 로고
    • Imaging longitudinal cardiac strain on short-axis images using strain-encoded MRI
    • Osman N.F., Sampath S., Atalar E., and Prince J.L. Imaging longitudinal cardiac strain on short-axis images using strain-encoded MRI. Magn Reson Med 46 (2001) 324-334
    • (2001) Magn Reson Med , vol.46 , pp. 324-334
    • Osman, N.F.1    Sampath, S.2    Atalar, E.3    Prince, J.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.