메뉴 건너뛰기




Volumn 28, Issue 9, 2007, Pages 719-725

Evaluation of reconstruction techniques in regional cerebral blood flow SPECT using trade-off plots: A Monte Carlo study

Author keywords

Image reconstruction (image processing, computer assisted); Monte Carlo (Monte Carlo method); RCBF; SPECT (tomography, emission computed, single photon)

Indexed keywords

HEXAMETHYLPROPYLENE AMINE OXIME TECHNETIUM TC 99M;

EID: 34547655846     PISSN: 01433636     EISSN: 14735628     Source Type: Journal    
DOI: 10.1097/MNM.0b013e328274204d     Document Type: Article
Times cited : (5)

References (30)
  • 1
    • 0028700063 scopus 로고
    • Accelerated image reconstruction using ordered subsets of projection data
    • Hudson H, Larkin R. Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imag 1994; 13:601-609.
    • (1994) IEEE Trans Med Imag , vol.13 , pp. 601-609
    • Hudson, H.1    Larkin, R.2
  • 2
    • 0030786648 scopus 로고    scopus 로고
    • A clinical perspective of accelerated statistical reconstruction
    • Hutton BF, Hudson HM, Beekman FJ. A clinical perspective of accelerated statistical reconstruction. Eur J Nucl Med 1997; 24:797-808.
    • (1997) Eur J Nucl Med , vol.24 , pp. 797-808
    • Hutton, B.F.1    Hudson, H.M.2    Beekman, F.J.3
  • 3
    • 0032318517 scopus 로고    scopus 로고
    • Properties of minimum cross-entropy reconstruction of emission tomography with anatomically based prior. In: Proceedings of the 1997 Medical Imaging Conference (MIC), 13-15 November 1997, Albuquerque, NM, USA.
    • Som S, Hutton BF, Braun M. Properties of minimum cross-entropy reconstruction of emission tomography with anatomically based prior. In: Proceedings of the 1997 Medical Imaging Conference (MIC), 13-15 November 1997, Albuquerque, NM, USA. IEEE Trans Nucl Sci 1998; 45:3014-3021.
    • (1998) IEEE Trans Nucl Sci , vol.45 , pp. 3014-3021
    • Som, S.1    Hutton, B.F.2    Braun, M.3
  • 5
    • 84942802774 scopus 로고    scopus 로고
    • Emission Tomography; The Fundamentals of PET and SPECT
    • San Diego, Elsevier Academic Press
    • Wernick MN, Aarsvold JN. Emission Tomography; The Fundamentals of PET and SPECT. San Diego: Elsevier Academic Press, 2004.
    • (2004)
    • Wernick, M.N.1    Aarsvold, J.N.2
  • 7
    • 16644390887 scopus 로고    scopus 로고
    • Seret A. Number of iterations when comparing MLEM/OSEM with FBP. J Nucl Med 2004; 45:2125; author reply, 2125-2126.
    • Seret A. Number of iterations when comparing MLEM/OSEM with FBP. J Nucl Med 2004; 45:2125; author reply, 2125-2126.
  • 10
    • 0033864431 scopus 로고    scopus 로고
    • Improvement of brain perfusion SPET using iterative reconstruction with scatter and non-uniform attenuation correction
    • Kauppinen T, Koskinen M, Alenius S, Vanninen E, Kuikka J. Improvement of brain perfusion SPET using iterative reconstruction with scatter and non-uniform attenuation correction. Eur J Nucl Med 2000; 27:1380-1386.
    • (2000) Eur J Nucl Med , vol.27 , pp. 1380-1386
    • Kauppinen, T.1    Koskinen, M.2    Alenius, S.3    Vanninen, E.4    Kuikka, J.5
  • 11
    • 0034887630 scopus 로고    scopus 로고
    • Clinical correlative evaluation of an iterative method for reconstruction of brain SPECT images
    • Nobili F, Vitali P, Calvini P, Bollati F, Girtler N, Delmonte M, et al. Clinical correlative evaluation of an iterative method for reconstruction of brain SPECT images. Nucl Med Biol 2001; 28:627-632.
    • (2001) Nucl Med Biol , vol.28 , pp. 627-632
    • Nobili, F.1    Vitali, P.2    Calvini, P.3    Bollati, F.4    Girtler, N.5    Delmonte, M.6
  • 12
    • 0036216263 scopus 로고    scopus 로고
    • Performance evaluation of OSEM reconstruction algorithm incorporating three-dimensional distance-dependent resolution compensation for brain SPECT: a simulation study
    • Yokoi T, Shinohara H, Onishi H. Performance evaluation of OSEM reconstruction algorithm incorporating three-dimensional distance-dependent resolution compensation for brain SPECT: a simulation study. Ann Nucl Med 2002; 16:11-18.
    • (2002) Ann Nucl Med , vol.16 , pp. 11-18
    • Yokoi, T.1    Shinohara, H.2    Onishi, H.3
  • 13
    • 38249017263 scopus 로고
    • Monte Carlo determination of emerging energy spectra for diagnostically realistic radiopharmaceutical distribution
    • Zubal IG, Harrel CR. Monte Carlo determination of emerging energy spectra for diagnostically realistic radiopharmaceutical distribution. Nucl Instrum Meth Phys Res 1990; A299:544-547.
    • (1990) Nucl Instrum Meth Phys Res , vol.A299 , pp. 544-547
    • Zubal, I.G.1    Harrel, C.R.2
  • 14
    • 38249012864 scopus 로고
    • Voxel based Monte Carlo calculations of nuclear medicine images and applied variance reduction techniques
    • Zubal IG, Harrell CR. Voxel based Monte Carlo calculations of nuclear medicine images and applied variance reduction techniques. Image and Vision Computing 1992; 10:342-348.
    • (1992) Image and Vision Computing , vol.10 , pp. 342-348
    • Zubal, I.G.1    Harrell, C.R.2
  • 16
    • 0034531753 scopus 로고    scopus 로고
    • Attenuation correction in quantitative SPECT of cerebral blood flow: a Monte Carlo study
    • Ärlig Å, Gustafsson A, Jacobsson L, Ljungberg M, Wikkelsö C. Attenuation correction in quantitative SPECT of cerebral blood flow: a Monte Carlo study. Phys Med Biol 2000; 45:3847-3859.
    • (2000) Phys Med Biol , vol.45 , pp. 3847-3859
    • Wikkelsö, C.1
  • 17
    • 0033769669 scopus 로고    scopus 로고
    • Dual-window scatter correction and energy window setting in cerebral blood flow SPECT: a Monte Carlo study
    • Gustafsson A, Arlig A, Jacobsson L, Ljungberg M, Wikkelso C. Dual-window scatter correction and energy window setting in cerebral blood flow SPECT: a Monte Carlo study. Phys Med Biol 2000; 45:3431-3440.
    • (2000) Phys Med Biol , vol.45 , pp. 3431-3440
    • Gustafsson, A.1    Arlig, A.2    Jacobsson, L.3    Ljungberg, M.4    Wikkelso, C.5
  • 18
    • 0024713937 scopus 로고
    • A Monte Carlo program for the simulation of scintillation camera characteristics
    • Ljungberg M, Strand S-E. A Monte Carlo program for the simulation of scintillation camera characteristics. Comp Meth Progr Biomed 1989; 29:257-272.
    • (1989) Comp Meth Progr Biomed , vol.29 , pp. 257-272
    • Ljungberg, M.1    Strand, S.-E.2
  • 19
    • 0003557081 scopus 로고
    • Methods for quantitating radioactivity in vivo by external counting measurements. PhD thesis
    • University of Wisconsin
    • Sörensen JA. Methods for quantitating radioactivity in vivo by external counting measurements. PhD thesis. University of Wisconsin; 1971.
    • (1971)
    • Sörensen, J.A.1
  • 20
    • 0021166670 scopus 로고
    • Improved SPECT quantification using compensation for scattered photons
    • Jaszczak RJ, Greer KL, Floyd Jr CE, Harris CC, Coleman RE. Improved SPECT quantification using compensation for scattered photons. J Nucl Med 1984; 25:893-900.
    • (1984) J Nucl Med , vol.25 , pp. 893-900
    • Jaszczak, R.J.1    Greer, K.L.2    Floyd, C.E.3
  • 21
    • 0025744078 scopus 로고
    • Treatment of Compton scattering in maximum-likelihood, expectation-maximization reconstructions of SPECT images
    • Bowsher JE, Floyd Jr CE. Treatment of Compton scattering in maximum-likelihood, expectation-maximization reconstructions of SPECT images. J Nucl Med 1991; 32:1285-1291.
    • (1991) J Nucl Med , vol.32 , pp. 1285-1291
    • Bowsher, J.E.1    Floyd, C.E.2
  • 22
    • 0032433120 scopus 로고    scopus 로고
    • Efficient scatter modelling for incorporation in maximum likelihood reconstruction
    • Hutton BF, Baccarne V. Efficient scatter modelling for incorporation in maximum likelihood reconstruction. Eur J Nucl Med 1998; 25:1658-1665.
    • (1998) Eur J Nucl Med , vol.25 , pp. 1658-1665
    • Hutton, B.F.1    Baccarne, V.2
  • 23
    • 0001190372 scopus 로고    scopus 로고
    • King MA, deVries DJ, Pan T-S, Pretorius PH, Case JA. An investigation of the filtering of TEW scatter estimates used to compensate for scatter with ordered subset reconstructions. In: Proceedings of the 1996 Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 3-9 November 1996. IEEE Trans Nucl Sci 1997; 44(3, pt. 2):1140-1145.
    • King MA, deVries DJ, Pan T-S, Pretorius PH, Case JA. An investigation of the filtering of TEW scatter estimates used to compensate for scatter with ordered subset reconstructions. In: Proceedings of the 1996 Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 3-9 November 1996. IEEE Trans Nucl Sci 1997; 44(3, pt. 2):1140-1145.
  • 25
    • 0003645230 scopus 로고
    • Digital Picture Processing. 2nd edn. vol. 1
    • Orlando, FL, USA, Academic Press
    • Rosenfeld A, Kak AC. Digital Picture Processing. 2nd edn. vol. 1. Orlando, FL, USA: Academic Press; 1982, pp. 369-383.
    • (1982) , pp. 369-383
    • Rosenfeld, A.1    Kak, A.C.2
  • 29
    • 31444450072 scopus 로고    scopus 로고
    • The number of subsets required for OSEM reconstruction in nuclear cardiology
    • Seret A. The number of subsets required for OSEM reconstruction in nuclear cardiology. Eur J Nucl Med Mol Imaging 2006; 33:231.
    • (2006) Eur J Nucl Med Mol Imaging , vol.33 , pp. 231
    • Seret, A.1
  • 30
    • 1142282561 scopus 로고    scopus 로고
    • Physics in Nuclear Medicine
    • Philadelphia, Saunders
    • Cherry SR, Sorenson JA, Phelps ME. Physics in Nuclear Medicine. Philadelphia: Saunders; 2003.
    • (2003)
    • Cherry, S.R.1    Sorenson, J.A.2    Phelps, M.E.3