메뉴 건너뛰기




Volumn 62, Issue 6-7 SPEC. ISS., 2007, Pages 544-548

Quantitative comparison of X-ray fluorescence microtomography setups: Standard and confocal collimator apparatus

Author keywords

Confocal scanning; Deposited dose; X ray fluorescence computer tomography

Indexed keywords

DATA ACQUISITION; FLUORESCENCE SPECTROSCOPY; IMAGING SYSTEMS; OPTICAL COLLIMATORS; TWO DIMENSIONAL;

EID: 34547638472     PISSN: 05848547     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sab.2007.02.020     Document Type: Article
Times cited : (17)

References (21)
  • 3
    • 5444238562 scopus 로고    scopus 로고
    • Confocal microscopic X-ray fluorescence at the Hasylab microfocus beamline: characteristics and possibilities
    • Janssens K., Proost K., and Falkenberg G. Confocal microscopic X-ray fluorescence at the Hasylab microfocus beamline: characteristics and possibilities. Spectrochim. Acta Part B 59 533 (2004) 1637-1645
    • (2004) Spectrochim. Acta Part B , vol.59 , Issue.533 , pp. 1637-1645
    • Janssens, K.1    Proost, K.2    Falkenberg, G.3
  • 5
    • 17044404699 scopus 로고    scopus 로고
    • Processing of three-dimensional microscopic X-ray fluorescence data
    • Vekemans B., Vincze L., Brenker F., and Adams F. Processing of three-dimensional microscopic X-ray fluorescence data. J. Anal. At. Spectrom. 19 (2004) 1302-1308
    • (2004) J. Anal. At. Spectrom. , vol.19 , pp. 1302-1308
    • Vekemans, B.1    Vincze, L.2    Brenker, F.3    Adams, F.4
  • 7
    • 26844551649 scopus 로고    scopus 로고
    • A model for the confocal volume of 3D micro X-ray fluorescence spectrometer
    • Malzer W., and Kanngiesser B. A model for the confocal volume of 3D micro X-ray fluorescence spectrometer. Spectrochim. Acta Part B 60 (2005) 1334-1341
    • (2005) Spectrochim. Acta Part B , vol.60 , pp. 1334-1341
    • Malzer, W.1    Kanngiesser, B.2
  • 10
    • 0026370093 scopus 로고
    • Fluorescent computer tomography: a model for correction of X-ray absorption
    • Hogan J.P., Gonsalves R.A., and Krieger A.S. Fluorescent computer tomography: a model for correction of X-ray absorption. IEEE Trans. Nucl. Sci. 38 (1991) 1721-1727
    • (1991) IEEE Trans. Nucl. Sci. , vol.38 , pp. 1721-1727
    • Hogan, J.P.1    Gonsalves, R.A.2    Krieger, A.S.3
  • 12
    • 0031996743 scopus 로고    scopus 로고
    • X-ray fluorescent computer tomography with synchrotron radiation
    • Rust G.F., and Weigelt J. X-ray fluorescent computer tomography with synchrotron radiation. IEEE Trans. Nucl. Sci. 45 (1998) 75-88
    • (1998) IEEE Trans. Nucl. Sci. , vol.45 , pp. 75-88
    • Rust, G.F.1    Weigelt, J.2
  • 16
    • 0036433357 scopus 로고    scopus 로고
    • Quantitative characterization of microsamples by X-ray fluorescence tomography
    • Chukalina M., Simionovici A., Snigirev A., and Jeffries T. Quantitative characterization of microsamples by X-ray fluorescence tomography. X-ray Spectrom. 31 (2002) 448-450
    • (2002) X-ray Spectrom. , vol.31 , pp. 448-450
    • Chukalina, M.1    Simionovici, A.2    Snigirev, A.3    Jeffries, T.4
  • 19
    • 0041340532 scopus 로고    scopus 로고
    • Internal elemental microanalysis combining X-ray fluorescence, Compton and transmission tomography
    • Golosio B., Simionovici A., Somogyi A., Lemelle L., Chukalina M., and Brunetti A. Internal elemental microanalysis combining X-ray fluorescence, Compton and transmission tomography. J. Appl. Phys. 94 (2003) 145-156
    • (2003) J. Appl. Phys. , vol.94 , pp. 145-156
    • Golosio, B.1    Simionovici, A.2    Somogyi, A.3    Lemelle, L.4    Chukalina, M.5    Brunetti, A.6
  • 20
    • 0035577666 scopus 로고    scopus 로고
    • Software for X-ray fluorescence and scattering tomographic reconstruction
    • Brunetti A., and Golosio B. Software for X-ray fluorescence and scattering tomographic reconstruction. Comput. Phys. Commun. 141 (2001) 412-425
    • (2001) Comput. Phys. Commun. , vol.141 , pp. 412-425
    • Brunetti, A.1    Golosio, B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.