메뉴 건너뛰기




Volumn 53, Issue 4, 2007, Pages 413-422

A passive sampler for the determination of carbonyl compounds in indoor air employing O-(4-cyano-2-ethoxybenzyl)hydroxylamine as reactive adsorbent

Author keywords

Carbonyl compounds; Indoor air; O (4 cyano 2 ethoxybenzyl)hydroxylamine; Passive sampler; Sampling rate

Indexed keywords

2,4 DINITROPHENYLHYDRAZINE; ACETALDEHYDE; ACETONE; ADSORBENT; CARBONYL DERIVATIVE; FORMALDEHYDE; O (4 CYANO 2 ETHOXYBENZYL)HYDROXYLAMINE; UNCLASSIFIED DRUG;

EID: 34547607224     PISSN: 13449702     EISSN: 13475207     Source Type: Journal    
DOI: 10.1248/jhs.53.413     Document Type: Article
Times cited : (11)

References (22)
  • 1
    • 0038170455 scopus 로고    scopus 로고
    • Residential Indoor, Outdoor, and Workplace Concentrations of Carbonyl Compounds: Relationships with Personal Exposure Concentrations and Correlation with Sources
    • Jurvelin, J. A., Edwards, R. D., Variainen, M., Pasanen, P. and Jantunen, M. J. (2003) Residential Indoor, Outdoor, and Workplace Concentrations of Carbonyl Compounds: Relationships with Personal Exposure Concentrations and Correlation with Sources. J. Air Waste Manage. Assoc., 53, 560-573.
    • (2003) J. Air Waste Manage. Assoc , vol.53 , pp. 560-573
    • Jurvelin, J.A.1    Edwards, R.D.2    Variainen, M.3    Pasanen, P.4    Jantunen, M.J.5
  • 2
    • 0033403386 scopus 로고    scopus 로고
    • Neural sensitization model for multiple chemical sensitivity: Overview of theory and empirical evidence
    • Bell, I. R., Baldwin, C. M., Fernandez, M. and Schwartz, G. E. (1999) Neural sensitization model for multiple chemical sensitivity: overview of theory and empirical evidence. Toxicol. Ind. Health, 15, 295-304.
    • (1999) Toxicol. Ind. Health , vol.15 , pp. 295-304
    • Bell, I.R.1    Baldwin, C.M.2    Fernandez, M.3    Schwartz, G.E.4
  • 3
    • 0033806294 scopus 로고    scopus 로고
    • Monitoring the ambient environment with diffusive samplers: Theory and practical considerations
    • Brown, R. H. (2000) Monitoring the ambient environment with diffusive samplers: theory and practical considerations. J. Environ. Monit., 2000, 1-9.
    • (2000) J. Environ. Monit , vol.2000 , pp. 1-9
    • Brown, R.H.1
  • 4
    • 0020128916 scopus 로고
    • Formaldehyde and other carbonyls in Los Angeles ambient air
    • Grosjean, D. (1982) Formaldehyde and other carbonyls in Los Angeles ambient air. Environ. Sci. Technol., 116, 254-262.
    • (1982) Environ. Sci. Technol , vol.116 , pp. 254-262
    • Grosjean, D.1
  • 5
    • 0021090937 scopus 로고
    • Determination of aliphatic aldehydes in air by liquid chromatography
    • Kuwata, K., Uebori, M., Yamasaki, H., Kuge, Y. and Kiso, Y. (1985) Determination of aliphatic aldehydes in air by liquid chromatography. Anal. Chem., 55, 2013-2016.
    • (1985) Anal. Chem , vol.55 , pp. 2013-2016
    • Kuwata, K.1    Uebori, M.2    Yamasaki, H.3    Kuge, Y.4    Kiso, Y.5
  • 6
    • 0022059963 scopus 로고
    • Determination of sub-part-per-million levels of formaldehyde in air using active or passive sampling on 2,4-dinitrophenylhydrazine-coated glass fiber filters and high-performance liquid chromatography
    • Levin, J. O., Andersson, K., Lindahl, R. and Nilsson, C. A. (1985) Determination of sub-part-per-million levels of formaldehyde in air using active or passive sampling on 2,4-dinitrophenylhydrazine-coated glass fiber filters and high-performance liquid chromatography. Anal. Chem., 57, 1032-1035.
    • (1985) Anal. Chem , vol.57 , pp. 1032-1035
    • Levin, J.O.1    Andersson, K.2    Lindahl, R.3    Nilsson, C.A.4
  • 7
    • 0022852537 scopus 로고
    • A passive sampler for formaldehyde in air using 2,4-dinitrophenylhydrazine-coated glass fiber filters
    • Levin, J. O., Lindahl, R. and Andersson, K. (1986) A passive sampler for formaldehyde in air using 2,4-dinitrophenylhydrazine-coated glass fiber filters. Environ. Sci. Technol., 20, 1273-1276.
    • (1986) Environ. Sci. Technol , vol.20 , pp. 1273-1276
    • Levin, J.O.1    Lindahl, R.2    Andersson, K.3
  • 8
    • 84914891148 scopus 로고
    • Monitoring of parts-per-billion levels of formaldehyde using a diffusive sampler
    • Levin, J. O., Lindahl, R. and Andersson, K. (1989) Monitoring of parts-per-billion levels of formaldehyde using a diffusive sampler. J. Air Pollut. Control Assoc., 39, 44-47.
    • (1989) J. Air Pollut. Control Assoc , vol.39 , pp. 44-47
    • Levin, J.O.1    Lindahl, R.2    Andersson, K.3
  • 9
    • 0024238669 scopus 로고
    • High performance liquid chromatographic determination of formaldehyde in air in the ppb to ppm range using diffusive sampling and hydrazone formation
    • Levin, J. O., Lindahl, R. and Andersson, K. (1988) High performance liquid chromatographic determination of formaldehyde in air in the ppb to ppm range using diffusive sampling and hydrazone formation. Environ. Technol. Lett., 9, 1423-1430.
    • (1988) Environ. Technol. Lett , vol.9 , pp. 1423-1430
    • Levin, J.O.1    Lindahl, R.2    Andersson, K.3
  • 10
    • 0033151462 scopus 로고    scopus 로고
    • A reactive and sensitive diffusion sampler for the determination of aldehydes and ketones in ambient air
    • Uchiyama, S., Asai, M. and Hasegawa, S. (1999) A reactive and sensitive diffusion sampler for the determination of aldehydes and ketones in ambient air. Atmos. Environ., 33, 1999-2005.
    • (1999) Atmos. Environ , vol.33 , pp. 1999-2005
    • Uchiyama, S.1    Asai, M.2    Hasegawa, S.3
  • 11
    • 7444261412 scopus 로고    scopus 로고
    • Evaluation of a diffusive sampler for measurement of carbonyl compounds in air
    • Uchiyama, S., Aoyagi, S. and Ando, M. (2004) Evaluation of a diffusive sampler for measurement of carbonyl compounds in air. Atmos. Environ., 38, 6319-6326.
    • (2004) Atmos. Environ , vol.38 , pp. 6319-6326
    • Uchiyama, S.1    Aoyagi, S.2    Ando, M.3
  • 12
    • 4644296337 scopus 로고    scopus 로고
    • Evaluation of the diffusive sampling device for the determination of formaldehyde in indoor air
    • Sekine, Y., Butsugan, M., Usuki, H. and Kitahara, T. (2001) Evaluation of the diffusive sampling device for the determination of formaldehyde in indoor air. J. Environ. Chem., 11, 511-516.
    • (2001) J. Environ. Chem , vol.11 , pp. 511-516
    • Sekine, Y.1    Butsugan, M.2    Usuki, H.3    Kitahara, T.4
  • 13
    • 28444476384 scopus 로고    scopus 로고
    • Problems in the simultaneous determination of some aldehydes using DNPH cartridge
    • Aoki, M. (2002) Problems in the simultaneous determination of some aldehydes using DNPH cartridge. J. Soc. Ind. Environ., Jpn., 5, 118-119.
    • (2002) J. Soc. Ind. Environ., Jpn , vol.5 , pp. 118-119
    • Aoki, M.1
  • 14
    • 0020362844 scopus 로고
    • Mutagenicity and toxicity of carcinogenic and other hydrazine derivatives: Correlation between toxic potency in animals and toxic potency in Salmonella typhimurium TA1538
    • Malca-Mor, L. and Stark, A. A. (1982) Mutagenicity and toxicity of carcinogenic and other hydrazine derivatives: Correlation between toxic potency in animals and toxic potency in Salmonella typhimurium TA1538. Appl. Environ. Microbiol., 44, 801-808.
    • (1982) Appl. Environ. Microbiol , vol.44 , pp. 801-808
    • Malca-Mor, L.1    Stark, A.A.2
  • 15
    • 0026944631 scopus 로고
    • A passive sampler for airborne formaldehyde
    • Grosjean, D. and Williams, II, E. L. (1992) A passive sampler for airborne formaldehyde. Atmos. Environ. Part A., 26, 2923-2928.
    • (1992) Atmos. Environ. Part A , vol.26 , pp. 2923-2928
    • Grosjean, D.1    Williams II, E.L.2
  • 16
    • 0024764128 scopus 로고
    • 2,4-dinitrophenylhydrazine-coated silica gel cartridge method for determination of formaldehyde in air. Identification of an ozone interference
    • Arnts, R. R. and Tejada, S. B. (1989) 2,4-dinitrophenylhydrazine-coated silica gel cartridge method for determination of formaldehyde in air. Identification of an ozone interference. Environ. Sci. Technol., 23, 1428-1430.
    • (1989) Environ. Sci. Technol , vol.23 , pp. 1428-1430
    • Arnts, R.R.1    Tejada, S.B.2
  • 17
    • 34547595468 scopus 로고    scopus 로고
    • Akiyama, K. and Nakayama, A. (2005) Analysis of low concentration aldehyde and ketone compounds in automotive exhaust gas by new collection reagent. SAE Tech. Pap. Ser., Report number SAE-2005-01-2152.
    • Akiyama, K. and Nakayama, A. (2005) Analysis of low concentration aldehyde and ketone compounds in automotive exhaust gas by new collection reagent. SAE Tech. Pap. Ser., Report number SAE-2005-01-2152.
  • 18
    • 28444495077 scopus 로고    scopus 로고
    • Evaluation of passive sampler for measurement of glutaraldehyde in occupational indoor air
    • Sekine, Y., Oikawa, D., Saitoh, K. and Asano, Y. (2005) Evaluation of passive sampler for measurement of glutaraldehyde in occupational indoor air. J. Health Sci., 51, 629-635.
    • (2005) J. Health Sci , vol.51 , pp. 629-635
    • Sekine, Y.1    Oikawa, D.2    Saitoh, K.3    Asano, Y.4
  • 19
    • 34547604582 scopus 로고    scopus 로고
    • Evaluation of solvent extraction type diffusion sampler for determination of VOCs in ambient air
    • Sekine, Y., Hirota, C. and Butsugan, M. (2002) Evaluation of solvent extraction type diffusion sampler for determination of VOCs in ambient air. J. Environ. Chem., 12, 847-854.
    • (2002) J. Environ. Chem , vol.12 , pp. 847-854
    • Sekine, Y.1    Hirota, C.2    Butsugan, M.3
  • 20
    • 0020533372 scopus 로고
    • Revised methods for the Salmonella mutagenicity test
    • Maron, D. M. and Ames, B. N. (1983) Revised methods for the Salmonella mutagenicity test. Mutat. Res., 113, 173-215.
    • (1983) Mutat. Res , vol.113 , pp. 173-215
    • Maron, D.M.1    Ames, B.N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.