메뉴 건너뛰기




Volumn 31, Issue 5, 2007, Pages 297-310

Performance of a non-load-bearing steel stud gypsum board wall assembly: Experiments and modelling

Author keywords

Compartmentation; Fire resistance; Heat flux; Partitions; Wall

Indexed keywords

COMPUTER SIMULATION; FIRE RESISTANCE; FLAMMABILITY TESTING; GYPSUM; HEAT FLUX; STEEL; STUDS (STRUCTURAL MEMBERS);

EID: 34547546370     PISSN: 03080501     EISSN: 10991018     Source Type: Journal    
DOI: 10.1002/fam.939     Document Type: Article
Times cited : (22)

References (21)
  • 1
    • 28644445123 scopus 로고    scopus 로고
    • Test Method for Fire Resistance Tests of Building Construction and Materials
    • American Society for Testing and Materials, ASTM E119-00a
    • American Society for Testing and Materials. Test Method for Fire Resistance Tests of Building Construction and Materials. ASTM E119-00a.
  • 2
    • 0003740302 scopus 로고    scopus 로고
    • International Organization for Standardization, Parts, International Organization for Standardization: Geneva, Switzerland
    • International Organization for Standardization. Fire Resistance Tests - Elements of Building Construction, ISO 834. Parts 1-9. International Organization for Standardization: Geneva, Switzerland.
    • Fire Resistance Tests - Elements of Building Construction, ISO 834 , pp. 1-9
  • 3
    • 34547550902 scopus 로고    scopus 로고
    • Prediction of the structural fire performance of buildings
    • San Francisco, CA
    • Bukowski RW. Prediction of the structural fire performance of buildings. Eighth Fire and Materials Conference, San Francisco, CA, 2003.
    • (2003) Eighth Fire and Materials Conference
    • Bukowski, R.W.1
  • 4
    • 0024777449 scopus 로고
    • Defining the thermal environment in fire tests
    • Keltner NR, Moya JL. Defining the thermal environment in fire tests. Fire and Materials 1989; 14:133-138.
    • (1989) Fire and Materials , vol.14 , pp. 133-138
    • Keltner, N.R.1    Moya, J.L.2
  • 6
    • 34547533517 scopus 로고    scopus 로고
    • CIB-W14. Rational Fire Safety Engineering Approach to Fire Resistance of Buildings, Publication 269, 2001.
    • CIB-W14. Rational Fire Safety Engineering Approach to Fire Resistance of Buildings, Publication 269, 2001.
  • 8
    • 84967158872 scopus 로고    scopus 로고
    • Standard Specification for Installation of Steel Framing Members to Receive Screw-Attached Gypsum Panel Products
    • American Society for Testing and Materials, ASTM C754-00
    • American Society for Testing and Materials. Standard Specification for Installation of Steel Framing Members to Receive Screw-Attached Gypsum Panel Products. ASTM C754-00.
  • 9
    • 28644452564 scopus 로고    scopus 로고
    • Standard Specification for Application of Finishing of Gypsum Board
    • American Society for Testing and Materials, ASTM C840-03
    • American Society for Testing and Materials. Standard Specification for Application of Finishing of Gypsum Board. ASTM C840-03.
  • 10
    • 34547527690 scopus 로고    scopus 로고
    • Standard Specification for Nonstructural Steel Framing Members
    • American Society for Testing and Materials, ASTM C654-00
    • American Society for Testing and Materials. Standard Specification for Nonstructural Steel Framing Members. ASTM C654-00.
  • 11
    • 28644433097 scopus 로고    scopus 로고
    • Standard Specification for Steel-Piercing Tapping Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Wood or Steel Studs
    • American Society for Testing and Materials, ASTM C1002-01
    • American Society for Testing and Materials. Standard Specification for Steel-Piercing Tapping Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Wood or Steel Studs. ASTM C1002-01.
  • 12
    • 84955749260 scopus 로고    scopus 로고
    • Federal building and fire safety investigation of the world trade center disaster: Experiments and modeling of the multiple workstations burning in a compartment
    • Hamins A, Maranghides A, McGrattan K, Ohlemiller T, Anleitner R. Federal building and fire safety investigation of the world trade center disaster: experiments and modeling of the multiple workstations burning in a compartment. NIST NCSTAR 1-5E, 2005.
    • (2005) NIST NCSTAR , vol.1-5E
    • Hamins, A.1    Maranghides, A.2    McGrattan, K.3    Ohlemiller, T.4    Anleitner, R.5
  • 14
    • 0036306022 scopus 로고    scopus 로고
    • Thermal properties of gypsum plasterboard at high temperatures
    • Thomas G. Thermal properties of gypsum plasterboard at high temperatures. Fire and Materials 2002; 26:37-45.
    • (2002) Fire and Materials , vol.26 , pp. 37-45
    • Thomas, G.1
  • 15
    • 0028510777 scopus 로고
    • A model for predicting heat transfer through gypsum-board/wood-stud walls exposed to fire
    • Mehaffey JR, Cuerrier P, Carisse GA. A model for predicting heat transfer through gypsum-board/wood-stud walls exposed to fire. Fire and Materials 1994; 18:297-305.
    • (1994) Fire and Materials , vol.18 , pp. 297-305
    • Mehaffey, J.R.1    Cuerrier, P.2    Carisse, G.A.3
  • 16
    • 0036557732 scopus 로고    scopus 로고
    • Fire resistance of lightweight timber framed walls
    • Collier PCR, Buchanan AH. Fire resistance of lightweight timber framed walls. Fire Technology 2002; 38:125-145.
    • (2002) Fire Technology , vol.38 , pp. 125-145
    • Collier, P.C.R.1    Buchanan, A.H.2
  • 19
    • 0030211647 scopus 로고    scopus 로고
    • A model for predicting heat transfer through noninsulated unloaded steel-stud gypsum board wall assemblies exposed to fire
    • Sultan MA. A model for predicting heat transfer through noninsulated unloaded steel-stud gypsum board wall assemblies exposed to fire. Fire Technology 1996; 32:239-259.
    • (1996) Fire Technology , vol.32 , pp. 239-259
    • Sultan, M.A.1
  • 20
    • 22744436536 scopus 로고    scopus 로고
    • Heat exposure in fire resistance furnaces: Full-scale vs intermediate-scale
    • San Francisco, CA
    • Sultan MA, Benichou N, Min BY. Heat exposure in fire resistance furnaces: full-scale vs intermediate-scale. Eighth Fire and Materials Conference, San Francisco, CA, 2003.
    • (2003) Eighth Fire and Materials Conference
    • Sultan, M.A.1    Benichou, N.2    Min, B.Y.3
  • 21
    • 0038216569 scopus 로고    scopus 로고
    • A model to predict the fire resistance of non-load bearing wood-stud walls
    • Takeda H. A model to predict the fire resistance of non-load bearing wood-stud walls. Fire and Materials 2003; 27:19-39.
    • (2003) Fire and Materials , vol.27 , pp. 19-39
    • Takeda, H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.