메뉴 건너뛰기




Volumn 48, Issue 3, 2007, Pages 393-397

Two cases of very late stent thrombosis after implantation of a sirolimus-eluting stent presenting as AMI

Author keywords

Drug eluting stent; Sirolimus; Stent thrombosis

Indexed keywords

ACETYLSALICYLIC ACID; CALCIUM ANTAGONIST; DIURETIC AGENT; RAPAMYCIN; TICLOPIDINE; VOGLIBOSE;

EID: 34547533555     PISSN: 13492365     EISSN: 13493299     Source Type: Journal    
DOI: 10.1536/ihj.48.393     Document Type: Article
Times cited : (10)

References (14)
  • 1
    • 11144356029 scopus 로고    scopus 로고
    • Stent thrombosis after successful sirolimus-eluting stent implantation
    • Jeremias A, Sylvia B, Bridges J, et al. Stent thrombosis after successful sirolimus-eluting stent implantation. Circulation 2004; 109: 1930-2.
    • (2004) Circulation , vol.109 , pp. 1930-1932
    • Jeremias, A.1    Sylvia, B.2    Bridges, J.3
  • 2
    • 2342645995 scopus 로고    scopus 로고
    • Incidence of thrombotic stent occlusion during the first three months after sirolimus-eluting stent implantation in 500 consecutive patients
    • Regar E, Lemos PA, Saia F, et al. Incidence of thrombotic stent occlusion during the first three months after sirolimus-eluting stent implantation in 500 consecutive patients. Am J Cardiol 2004; 93: 1271-5.
    • (2004) Am J Cardiol , vol.93 , pp. 1271-1275
    • Regar, E.1    Lemos, P.A.2    Saia, F.3
  • 3
    • 33751108742 scopus 로고    scopus 로고
    • Late angiographic stent thrombosis in a drug-eluting stent that occurred 20 months after premature discontinuation of clopidogrel administration
    • Yang J, Wang N, Zhang X, et al. Late angiographic stent thrombosis in a drug-eluting stent that occurred 20 months after premature discontinuation of clopidogrel administration. Int Heart J 2006; 47: 707-13.
    • (2006) Int Heart J , vol.47 , pp. 707-713
    • Yang, J.1    Wang, N.2    Zhang, X.3
  • 5
    • 17844373254 scopus 로고    scopus 로고
    • Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents
    • Iakovou I, Schmidt T, Bonizzoni E, et al. Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents. JAMA 2005; 293: 2126-30.
    • (2005) JAMA , vol.293 , pp. 2126-2130
    • Iakovou, I.1    Schmidt, T.2    Bonizzoni, E.3
  • 6
    • 20044388113 scopus 로고    scopus 로고
    • Drug-eluting stent thrombosis: Results from a pooled analysis including 10 randomized studies
    • Moreno R, Fernandez C, Hernandez R. et al. Drug-eluting stent thrombosis: results from a pooled analysis including 10 randomized studies, J Am Coll Cardiol 2005; 45: 954-9.
    • (2005) J Am Coll Cardiol , vol.45 , pp. 954-959
    • Moreno, R.1    Fernandez, C.2    Hernandez, R.3
  • 7
    • 20144388922 scopus 로고    scopus 로고
    • Stent underexpression and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: An intravascular ultrasound study
    • Fujii K, Carlier SG, Mintz GS, et al. Stent underexpression and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: an intravascular ultrasound study. J Am Coll Cardiol 2005; 45: 995-8.
    • (2005) J Am Coll Cardiol , vol.45 , pp. 995-998
    • Fujii, K.1    Carlier, S.G.2    Mintz, G.S.3
  • 8
    • 0035901621 scopus 로고    scopus 로고
    • Stent thrombosis in the modern era: A pooled analysis of multicenter coronary stent clinical trials
    • Cutlip DE, Baim DS, Ho KK, et al. Stent thrombosis in the modern era: a pooled analysis of multicenter coronary stent clinical trials. Circulation 2001; 103: 1967-71.
    • (2001) Circulation , vol.103 , pp. 1967-1971
    • Cutlip, D.E.1    Baim, D.S.2    Ho, K.K.3
  • 9
    • 0032963630 scopus 로고    scopus 로고
    • Cause of in-hospital death in 12,232 consecutive patients undergoing percutaneous transluminal coronary angioplasty. The Northern New England Cardiovascular Disease Study Group
    • Malenka DJ, O'Rourke D, Miller MA, et al. Cause of in-hospital death in 12,232 consecutive patients undergoing percutaneous transluminal coronary angioplasty. The Northern New England Cardiovascular Disease Study Group. Am Heart J 1999; 137: 632-8.
    • (1999) Am Heart J , vol.137 , pp. 632-638
    • Malenka, D.J.1    O'Rourke, D.2    Miller, M.A.3
  • 10
    • 10744229988 scopus 로고    scopus 로고
    • Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: Should we be cautious?
    • Virmani R, Guagliumi G, Farb A, et al. Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious? Circulation 2004; 109: 701-5.
    • (2004) Circulation , vol.109 , pp. 701-705
    • Virmani, R.1    Guagliumi, G.2    Farb, A.3
  • 11
    • 0037137302 scopus 로고    scopus 로고
    • Mechanism of late in-stent restenosis after implantation of a paclitaxel derivate-eluting polymer stent system in humans
    • Virmani R, Liistro F, Stankovic G, et al. Mechanism of late in-stent restenosis after implantation of a paclitaxel derivate-eluting polymer stent system in humans. Circulation 2002; 106: 2649-51.
    • (2002) Circulation , vol.106 , pp. 2649-2651
    • Virmani, R.1    Liistro, F.2    Stankovic, G.3
  • 12
    • 0141885290 scopus 로고    scopus 로고
    • Pathological mechanisms of fatal late coronary stent thrombosis in humans
    • Farb A, Burke AP, Kolodgie FD, Virmani R. Pathological mechanisms of fatal late coronary stent thrombosis in humans. Circulation 2003; 108: 1701-6.
    • (2003) Circulation , vol.108 , pp. 1701-1706
    • Farb, A.1    Burke, A.P.2    Kolodgie, F.D.3    Virmani, R.4
  • 13
    • 0029761378 scopus 로고    scopus 로고
    • Marked inflammatory sequelae to implantation of biodegradable and nonbiodegradable polymers in porcine coronary arteries
    • van der Giessen WJ, Lincoff AM, Schwartz RS, et al. Marked inflammatory sequelae to implantation of biodegradable and nonbiodegradable polymers in porcine coronary arteries. Circulation 1996; 94: 1690-7.
    • (1996) Circulation , vol.94 , pp. 1690-1697
    • van der Giessen, W.J.1    Lincoff, A.M.2    Schwartz, R.S.3
  • 14
    • 34547540387 scopus 로고    scopus 로고
    • FDA Advises Physicians of Adverse Events Associated with Cordis Cypher Coronary Stents. US Food and Drug Administration Public Health Web Notification 2003; T03-71.
    • FDA Advises Physicians of Adverse Events Associated with Cordis Cypher Coronary Stents. US Food and Drug Administration Public Health Web Notification 2003; T03-71.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.