메뉴 건너뛰기




Volumn 22, Issue 4, 2007, Pages 245-250

A noninvasive sizing method to choose fitted Amplatzer septal occluder by transthoracic echocardiography in patients with secundum atrial septal defects

Author keywords

Amplatzer septal occluder; Atrial septal defect; Transcatheter device closure

Indexed keywords

ACETYLSALICYLIC ACID; CEFAZOLIN; GENTAMICIN; HEPARIN;

EID: 34547482334     PISSN: 09108327     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00380-006-0959-4     Document Type: Article
Times cited : (10)

References (18)
  • 1
    • 0032846406 scopus 로고    scopus 로고
    • Transcatheter closure of atrial septal defect and interatrial communications with a new self expanding nitinol double dis device (Amplatzer septal occluder): Multicenter UK experience
    • 10455079 1:STN:280:DyaK1Mzoslahtw%3D%3D
    • KC Chan MJ Godman K Walsh 1999 Transcatheter closure of atrial septal defect and interatrial communications with a new self expanding nitinol double dis device (Amplatzer septal occluder): Multicenter UK experience Heart 82 300-306 10455079 1:STN:280:DyaK1Mzoslahtw%3D%3D
    • (1999) Heart , vol.82 , pp. 300-306
    • Chan, K.C.1    Godman, M.J.2    Walsh, K.3
  • 2
    • 0028888565 scopus 로고
    • Echocardiographic predictors of candidacy for successful transcatheter atrial septal defect closure
    • 7728848 10.1002/ccd.1810340308 1:STN:280:ByqB2cnht1Y%3D
    • HM Rosenfeld ME van der Velde SP Sanders SD Colan IA Parness JE Lock PJ Spevak 1995 Echocardiographic predictors of candidacy for successful transcatheter atrial septal defect closure Cathet Cardiovasc Diagn 34 29-34 7728848 10.1002/ccd.1810340308 1:STN:280:ByqB2cnht1Y%3D
    • (1995) Cathet Cardiovasc Diagn , vol.34 , pp. 29-34
    • Rosenfeld, H.M.1    van der Velde, M.E.2    Sanders, S.P.3    Colan, S.D.4    Parness, I.A.5    Lock, J.E.6    Spevak, P.J.7
  • 3
    • 0037134954 scopus 로고    scopus 로고
    • Transcatheter closure of patent foramen ovale in patients with cerebral ischemia
    • 12084603 10.1016/S0735-1097(02)01904-6
    • MU Braun D Fassbender SP Schoen 2002 Transcatheter closure of patent foramen ovale in patients with cerebral ischemia J Am Coll Cardiol 39 2019-2025 12084603 10.1016/S0735-1097(02)01904-6
    • (2002) J Am Coll Cardiol , vol.39 , pp. 2019-2025
    • Braun, M.U.1    Fassbender, D.2    Schoen, S.P.3
  • 4
    • 0037024255 scopus 로고    scopus 로고
    • Comparison between transcatheter and surgical closure of secundum atrial septal defect in children and adults: Results of a multicenter nonrandomized trial
    • Amplatzer Investigators 12039500 10.1016/S0735-1097(02)01862-4
    • ZD Du ZM Hijazi CS Kleinman NH Silverman K Larntz Amplatzer Investigators 2002 Comparison between transcatheter and surgical closure of secundum atrial septal defect in children and adults: Results of a multicenter nonrandomized trial J Am Coll Cardiol 39 1836-1844 12039500 10.1016/S0735-1097(02)01862-4
    • (2002) J Am Coll Cardiol , vol.39 , pp. 1836-1844
    • Du, Z.D.1    Hijazi, Z.M.2    Kleinman, C.S.3    Silverman, N.H.4    Larntz, K.5
  • 5
    • 0034863750 scopus 로고    scopus 로고
    • The role of transesophageal echocardiography in transcatheter closure of secundum atrial septal defects by the Amplatzer Septal Occluder
    • 11526362 10.1067/mhj.2001.116770 1:STN:280:DC%2BD3Mvot1KhsQ%3D%3D
    • U Mazic P Gavora J Masura 2001 The role of transesophageal echocardiography in transcatheter closure of secundum atrial septal defects by the Amplatzer Septal Occluder Am Heart J 142 482-488 11526362 10.1067/mhj.2001.116770 1:STN:280:DC%2BD3Mvot1KhsQ%3D%3D
    • (2001) Am Heart J , vol.142 , pp. 482-488
    • Mazic, U.1    Gavora, P.2    Masura, J.3
  • 6
    • 0002350613 scopus 로고    scopus 로고
    • Transcatheter closure of secundum atrial septal defects using the Amplatzer septal occluder: Clinical experience and technical considerations
    • DJ Waight PR Koenig QL Cao 2002 Transcatheter closure of secundum atrial septal defects using the Amplatzer septal occluder: Clinical experience and technical considerations Curr Intervent Cardiol Rep 2 70-77
    • (2002) Curr Intervent Cardiol Rep , vol.2 , pp. 70-77
    • Waight, D.J.1    Koenig, P.R.2    Cao, Q.L.3
  • 7
    • 0035143017 scopus 로고    scopus 로고
    • Transcatheter closure of atrial septal defects and patent foramen ovale under intracardiac echocardiographic guidance: Feasibility and comparison with transesophageal echocardiography
    • 11170327 10.1002/1522-726X(200102)52:2<194::AID-CCD1046>3.0.CO;2-4 1:STN:280:DC%2BD3M3jt1yjug%3D%3D
    • ZM Hijazi Z Wang QL Cao P Koenig D Waight R Lang 2001 Transcatheter closure of atrial septal defects and patent foramen ovale under intracardiac echocardiographic guidance: Feasibility and comparison with transesophageal echocardiography Catheter Cardiovasc Interv 52 194-199 11170327 10.1002/1522-726X(200102)52:2<194::AID-CCD1046>3.0.CO;2-4 1:STN:280:DC%2BD3M3jt1yjug%3D%3D
    • (2001) Catheter Cardiovasc Interv , vol.52 , pp. 194-199
    • Hijazi, Z.M.1    Wang, Z.2    Cao, Q.L.3    Koenig, P.4    Waight, D.5    Lang, R.6
  • 8
    • 0037438812 scopus 로고    scopus 로고
    • Intracardiac echocardiography guided device closure of atrial septal defects
    • 12535824 10.1016/S0735-1097(02)02616-5
    • MJ Mullen BF Dias F Walker SC Siu LN Benson PR McLaughin 2003 Intracardiac echocardiography guided device closure of atrial septal defects J Am Coll Cardiol 41 285-292 12535824 10.1016/ S0735-1097(02)02616-5
    • (2003) J Am Coll Cardiol , vol.41 , pp. 285-292
    • Mullen, M.J.1    Dias, B.F.2    Walker, F.3    Siu, S.C.4    Benson, L.N.5    McLaughin, P.R.6
  • 9
    • 0037448797 scopus 로고    scopus 로고
    • Intracardiac echocardiography is superior to conventional monitoring for guiding closure of interatrial communications
    • 12591745 10.1161/01.CIR.0000057547.00909.1C
    • T Bartel T Konorza J Arjumand 2003 Intracardiac echocardiography is superior to conventional monitoring for guiding closure of interatrial communications Circulation 107 795-797 12591745 10.1161/ 01.CIR.0000057547.00909.1C
    • (2003) Circulation , vol.107 , pp. 795-797
    • Bartel, T.1    Konorza, T.2    Arjumand, J.3
  • 10
    • 0345548439 scopus 로고    scopus 로고
    • Use of intracardiac echocardiography to guide catheter closure of atrial communications
    • 14641386 10.1111/j.0742-2822.2003.03039.x
    • PR Koenig RI Abdulla QL Cao ZM Hijazi 2003 Use of intracardiac echocardiography to guide catheter closure of atrial communications Echocardiography 20 8 781-787 14641386 10.1111/j.0742-2822.2003.03039.x
    • (2003) Echocardiography , vol.20 , Issue.8 , pp. 781-787
    • Koenig, P.R.1    Abdulla, R.I.2    Cao, Q.L.3    Hijazi, Z.M.4
  • 11
    • 1242338045 scopus 로고    scopus 로고
    • Comparison of intracardiac echocardiography versus transesophageal echocardiography guidance for percutaneous transcatheter closure of atrial septal defect
    • 14969617 10.1016/j.amjcard.2003.10.037
    • F Boccalandro E Baptista A Muench C Carter RW Smalling 2004 Comparison of intracardiac echocardiography versus transesophageal echocardiography guidance for percutaneous transcatheter closure of atrial septal defect Am J Cardiol 93 4 437-440 14969617 10.1016/j.amjcard.2003.10.037
    • (2004) Am J Cardiol , vol.93 , Issue.4 , pp. 437-440
    • Boccalandro, F.1    Baptista, E.2    Muench, A.3    Carter, C.4    Smalling, R.W.5
  • 12
    • 0031467061 scopus 로고    scopus 로고
    • Transcatheter closure of secundum atrial septal defects using the new self-centering Amplatzer Septal Occluder: Initial human experience
    • 9408617 10.1002/ (SICI)1097-0304(199712)42:4<388::AID-CCD7>3.0.CO;2-7 1:STN:280:DyaK1c%2Fnt12itw%3D%3D
    • J Masura P Gavora A Formanek ZM Hijazi 1997 Transcatheter closure of secundum atrial septal defects using the new self-centering Amplatzer Septal Occluder: Initial human experience Cathet Cardiovasc Diagn 42 388-393 9408617 10.1002/ (SICI)1097-0304(199712)42:4<388::AID-CCD7>3.0.CO;2-7 1:STN:280:DyaK1c%2Fnt12itw%3D%3D
    • (1997) Cathet Cardiovasc Diagn , vol.42 , pp. 388-393
    • Masura, J.1    Gavora, P.2    Formanek, A.3    Hijazi, Z.M.4
  • 13
    • 0142217151 scopus 로고    scopus 로고
    • ASD closure with the Amplatzer device
    • 14603797 10.1046/j.1540-8183.2003.01006.x
    • HJ Faella AM Sciegata JL Alonso L Jmelnitsky 2003 ASD closure with the Amplatzer device J Interv Cardiol 16 5 393-397 14603797 10.1046/ j.1540-8183.2003.01006.x
    • (2003) J Interv Cardiol , vol.16 , Issue.5 , pp. 393-397
    • Faella, H.J.1    Sciegata, A.M.2    Alonso, J.L.3    Jmelnitsky, L.4
  • 14
    • 10744222807 scopus 로고    scopus 로고
    • Indication and techniques of transcatheter closure of patent foramen ovale
    • 14632952 10.1046/j.1540-8183.2003.01054.x Review
    • R Schrader 2003 Indication and techniques of transcatheter closure of patent foramen ovale J Interv Cardiol 16 6 543-551 14632952 10.1046/ j.1540-8183.2003.01054.x Review
    • (2003) J Interv Cardiol , vol.16 , Issue.6 , pp. 543-551
    • Schrader, R.1
  • 15
    • 0345275838 scopus 로고    scopus 로고
    • Novel technique to prevent prolapse of the Amplatzer septal occluder through large atrial septal defect
    • 14624439 10.1002/ccd.10686
    • HA Wahab AR Bairam QL Cao ZM Hijazi 2003 Novel technique to prevent prolapse of the Amplatzer septal occluder through large atrial septal defect Catheter Cardiovasc Interv 60 4 543-545 14624439 10.1002/ccd.10686
    • (2003) Catheter Cardiovasc Interv , vol.60 , Issue.4 , pp. 543-545
    • Wahab, H.A.1    Bairam, A.R.2    Cao, Q.L.3    Hijazi, Z.M.4
  • 16
    • 3042823189 scopus 로고    scopus 로고
    • New echocardiographic diameter for Amplatzer sizing in adult patients with secundum atrial septal defect: Preliminary results
    • 15224314 10.1002/ccd.20083
    • A Carcagni P Presbitero 2004 New echocardiographic diameter for Amplatzer sizing in adult patients with secundum atrial septal defect: preliminary results Catheter Cardiovasc Interv 62 3 409-414 15224314 10.1002/ccd.20083
    • (2004) Catheter Cardiovasc Interv , vol.62 , Issue.3 , pp. 409-414
    • Carcagni, A.1    Presbitero, P.2
  • 17
    • 0742272738 scopus 로고    scopus 로고
    • Percutaneous closure of patent foramen ovale: Impact of device design on safety and efficacy
    • 14729794 10.1136/hrt.2002.003111 1:STN:280:DC%2BD2c%2FivFGmsA%3D%3D
    • M Schwerzmann S Windecker A Wahl H Mehta K Nedeltchev H Mattle C Seiler B Meier 2004 Percutaneous closure of patent foramen ovale: Impact of device design on safety and efficacy Heart 90 2 186-190 14729794 10.1136/ hrt.2002.003111 1:STN:280:DC%2BD2c%2FivFGmsA%3D%3D
    • (2004) Heart , vol.90 , Issue.2 , pp. 186-190
    • Schwerzmann, M.1    Windecker, S.2    Wahl, A.3    Mehta, H.4    Nedeltchev, K.5    Mattle, H.6    Seiler, C.7    Meier, B.8
  • 18
    • 0026566731 scopus 로고
    • Morphological study of defects of the atrial septum within the oval fossa: Implications for transcatheter closure of left-to-right shunt
    • 1389707 1:STN:280:ByyD3c7otV0%3D
    • SMAG Ferreira SY Ho RH Anderson 1992 Morphological study of defects of the atrial septum within the oval fossa: Implications for transcatheter closure of left-to-right shunt Br Heart J 67 316-320 1389707 1:STN:280:ByyD3c7otV0%3D
    • (1992) Br Heart J , vol.67 , pp. 316-320
    • Ferreira, S.M.A.G.1    Ho, S.Y.2    Anderson, R.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.