메뉴 건너뛰기




Volumn 15, Issue 15, 2007, Pages 9254-9266

Dual beam heterodyne Fourier domain optical coherence tomography

Author keywords

[No Author keywords available]

Indexed keywords

CATHETERS; FOURIER TRANSFORMS; HETERODYNING; OPTICAL TOMOGRAPHY; PHASE STABILITY; SIGNAL TO NOISE RATIO;

EID: 34547469627     PISSN: None     EISSN: 10944087     Source Type: Journal    
DOI: 10.1364/OE.15.009254     Document Type: Article
Times cited : (36)

References (30)
  • 1
    • 0001936881 scopus 로고
    • Measurement of Intraocular Distances by Backscattering Spectral Interferometry
    • A. F. Fercher, C. K. Hitzenberger, G. Ramp, and S. Y. Elzaiat, "Measurement of Intraocular Distances by Backscattering Spectral Interferometry," Opt. Commun. 117, 43-48 (1995).
    • (1995) Opt. Commun , vol.117 , pp. 43-48
    • Fercher, A.F.1    Hitzenberger, C.K.2    Ramp, G.3    Elzaiat, S.Y.4
  • 2
    • 0038618462 scopus 로고    scopus 로고
    • Performance of Fourier domain vs. time domain optical coherence tomography
    • R. Leitgeb, C. R. Hitzenberger, and A. F. Fercher, "Performance of Fourier domain vs. time domain optical coherence tomography," Opt. Express 11, 889-894 (2003).
    • (2003) Opt. Express , vol.11 , pp. 889-894
    • Leitgeb, R.1    Hitzenberger, C.R.2    Fercher, A.F.3
  • 3
    • 0242301675 scopus 로고    scopus 로고
    • J. F. de Boer, B. Cense, B. H. Park, M. C. Pierce, G. J. Tearney, and B. E. Bouma, Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography, Opt. Lett. 28, 20672069 (2003).
    • J. F. de Boer, B. Cense, B. H. Park, M. C. Pierce, G. J. Tearney, and B. E. Bouma, "Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography," Opt. Lett. 28, 20672069 (2003).
  • 4
    • 2942703878 scopus 로고    scopus 로고
    • Sensitivity advantage of swept source and Fourier domain optical, coherence tomography
    • M. A. Choma, M. V. Sarunic, C. Yang, and J. Izatt, "Sensitivity advantage of swept source and Fourier domain optical, coherence tomography," Opt. Express 11, 2183-2189 (2003).
    • (2003) Opt. Express , vol.11 , pp. 2183-2189
    • Choma, M.A.1    Sarunic, M.V.2    Yang, C.3    Izatt, J.4
  • 7
    • 1542398242 scopus 로고    scopus 로고
    • In vivo human retinal imaging by ultrahigh-speed spectral, domain optical coherence tomography
    • N. Nassif, B. Cense, B. H. Park, S. H. Yun, T. C. Chen, B. E. Bouma, G. J. Tearney, and J. F. de Boer, "In vivo human retinal imaging by ultrahigh-speed spectral, domain optical coherence tomography," Opt. Lett. 29, 480-482 (2004).
    • (2004) Opt. Lett , vol.29 , pp. 480-482
    • Nassif, N.1    Cense, B.2    Park, B.H.3    Yun, S.H.4    Chen, T.C.5    Bouma, B.E.6    Tearney, G.J.7    de Boer, J.F.8
  • 8
    • 0142093656 scopus 로고    scopus 로고
    • High-speed wavelength-swept semiconductor laser with a polygon-scanner-based wavelength filter
    • S. H. Yun, C. Boudoux, G. J. Tearney, and B. E. Bouma, "High-speed wavelength-swept semiconductor laser with a polygon-scanner-based wavelength filter," Opt. Lett. 28, 1981-1983 (2003).
    • (2003) Opt. Lett , vol.28 , pp. 1981-1983
    • Yun, S.H.1    Boudoux, C.2    Tearney, G.J.3    Bouma, B.E.4
  • 9
    • 29244445929 scopus 로고    scopus 로고
    • Swept source optical coherence tomography using an all-fiber 1300nm ring laser source
    • M. A. Choma, K. Hsu, and J. A. Izatt, "Swept source optical coherence tomography using an all-fiber 1300nm ring laser source," J. Biomed. Opt. 10, 44009 (2005).
    • (2005) J. Biomed. Opt , vol.10 , pp. 44009
    • Choma, M.A.1    Hsu, K.2    Izatt, J.A.3
  • 10
    • 21244433547 scopus 로고    scopus 로고
    • R. Huber, M. Wojtkowski, K. Taira, J. G. Fujimoto, and K. Hsu, Amplified, frequency swept lasers for frequency domain reflectometry and OCT imaging: design and scaling principles, Opt. Express 13, 35133528 (2005).
    • R. Huber, M. Wojtkowski, K. Taira, J. G. Fujimoto, and K. Hsu, "Amplified, frequency swept lasers for frequency domain reflectometry and OCT imaging: design and scaling principles," Opt. Express 13, 35133528 (2005).
  • 11
    • 33144485776 scopus 로고    scopus 로고
    • Heterodyne Fourier domain optical, coherence tomography for full range probing with high axial resolution
    • A.H. Bachinann, R. A. Leitgeb, and T. Lasser, "Heterodyne Fourier domain optical, coherence tomography for full range probing with high axial resolution," Opt. Express 14, 1487-1496 (2006).
    • (2006) Opt. Express , vol.14 , pp. 1487-1496
    • Bachinann, A.H.1    Leitgeb, R.A.2    Lasser, T.3
  • 12
    • 12844270508 scopus 로고    scopus 로고
    • Removal of a mirror image and enhancement of the signal-to-noise ratio in Fourier-domain optical coherence tomography using an electro-optic phase modulator
    • J. Zhang, J. S. Nelson, and Z. P. Chen, "Removal of a mirror image and enhancement of the signal-to-noise ratio in Fourier-domain optical coherence tomography using an electro-optic phase modulator," Opt. Lett. 30, 147-149 (2005).
    • (2005) Opt. Lett , vol.30 , pp. 147-149
    • Zhang, J.1    Nelson, J.S.2    Chen, Z.P.3
  • 13
    • 9144220962 scopus 로고    scopus 로고
    • Removing the depth-degeneracy in optical frequency domain imaging with frequency shifting
    • S. H. Yun, G. J. Tearney, J. F. de Boer, and B. E. Bouma, "Removing the depth-degeneracy in optical frequency domain imaging with frequency shifting," Opt, Express 12, 4822-4828 (2004).
    • (2004) Opt, Express , vol.12 , pp. 4822-4828
    • Yun, S.H.1    Tearney, G.J.2    de Boer, J.F.3    Bouma, B.E.4
  • 14
    • 29244452237 scopus 로고    scopus 로고
    • Heterodyne swept-source optical coherence tomography for complete complex conjugate ambiguity removal
    • A. M. Davis, M. A. Choma, and J. A. Izatt, "Heterodyne swept-source optical coherence tomography for complete complex conjugate ambiguity removal," J. Biomed. Opt. 10 (2005).
    • (2005) J. Biomed. Opt , vol.10
    • Davis, A.M.1    Choma, M.A.2    Izatt, J.A.3
  • 16
    • 33745449623 scopus 로고    scopus 로고
    • Full-field swept-source phase microscopy
    • M. V. Sarunic, S. Weinberg, and J. A. Izatt, "Full-field swept-source phase microscopy," Opt. Lett. 31, 1462-1464 (2006).
    • (2006) Opt. Lett , vol.31 , pp. 1462-1464
    • Sarunic, M.V.1    Weinberg, S.2    Izatt, J.A.3
  • 17
    • 24344490411 scopus 로고    scopus 로고
    • Spectral-domain optical, coherence phase microscopy for quantitative phase-contrast imaging
    • C. Joo, T. Akkin, B. Cense, B. H. Park, and J. F. De Boer, "Spectral-domain optical, coherence phase microscopy for quantitative phase-contrast imaging," Opt, Lett. 30, 2131-2133 (2005).
    • (2005) Opt, Lett , vol.30 , pp. 2131-2133
    • Joo, C.1    Akkin, T.2    Cense, B.3    Park, B.H.4    De Boer, J.F.5
  • 18
    • 33847612515 scopus 로고    scopus 로고
    • Phase-sensitive optical coherence tomography at up to 370,000 lines per second using buffered Fourier domain mode-locked lasers
    • D. C. Adler, R. Huber, and J. G. Fujimoto, "Phase-sensitive optical coherence tomography at up to 370,000 lines per second using buffered Fourier domain mode-locked lasers," Opt. Lett. 32, 626-628 (2007).
    • (2007) Opt. Lett , vol.32 , pp. 626-628
    • Adler, D.C.1    Huber, R.2    Fujimoto, J.G.3
  • 19
    • 33847634901 scopus 로고    scopus 로고
    • Spectral-domain optical coherence phase and multiphoton microscopy
    • C. Joo, K. H. Kim, and J. F. De Boer, "Spectral-domain optical coherence phase and multiphoton microscopy," Opt. Lett. 32, 623-625 (2007).
    • (2007) Opt. Lett , vol.32 , pp. 623-625
    • Joo, C.1    Kim, K.H.2    De Boer, J.F.3
  • 20
    • 33644746298 scopus 로고    scopus 로고
    • Endoscope-tip interferometer for ultrahigh resolution frequency domain optical, coherence tomography in mouse colon
    • A. R. Tumlinson, J. K. Barton, B. Povazay, H. Sattman, A. Unterhuber, R. A. Leitgeb, and W. Drexler, "Endoscope-tip interferometer for ultrahigh resolution frequency domain optical, coherence tomography in mouse colon," Opt. Express 14, 1878-1887 (2006).
    • (2006) Opt. Express , vol.14 , pp. 1878-1887
    • Tumlinson, A.R.1    Barton, J.K.2    Povazay, B.3    Sattman, H.4    Unterhuber, A.5    Leitgeb, R.A.6    Drexler, W.7
  • 21
    • 33746388967 scopus 로고    scopus 로고
    • Doppler flow imaging of cytoplasmic streaming using spectral domain, phase microscopy
    • M. A. Choma, A. K. Ellerbee, S. Yazdanfar, and J. A. Izatt, "Doppler flow imaging of cytoplasmic streaming using spectral domain, phase microscopy," J. Biomed. Opt. 11 (2006).
    • (2006) J. Biomed. Opt , vol.11
    • Choma, M.A.1    Ellerbee, A.K.2    Yazdanfar, S.3    Izatt, J.A.4
  • 23
    • 0026101781 scopus 로고
    • Optical Measurement of the Axial Eye Length by Laser Doppler Interferometry
    • C. K. Hitzenberger, "Optical Measurement of the Axial Eye Length by Laser Doppler Interferometry," Investigative Ophthalmology & Visual Science 32, 616-624 (1991).
    • (1991) Investigative Ophthalmology & Visual Science , vol.32 , pp. 616-624
    • Hitzenberger, C.K.1
  • 24
    • 0034300727 scopus 로고    scopus 로고
    • Design, simulations and experimental investigations of a compact single mirror tip/tilt laser scanner
    • M. Hafez, T. C. Sidler, R. P. Salathe, G. L. M. Jansen, and J. C. Compter, "Design, simulations and experimental investigations of a compact single mirror tip/tilt laser scanner," Mechatronics 10, 741-760 (2000).
    • (2000) Mechatronics , vol.10 , pp. 741-760
    • Hafez, M.1    Sidler, T.C.2    Salathe, R.P.3    Jansen, G.L.M.4    Compter, J.C.5
  • 26
    • 0031647395 scopus 로고    scopus 로고
    • Signal and resolution enhancements in dual beam optical coherence tomography of the human eye
    • A. Baumgartner, C. K. Hitzenberger, H. Sattmann, W. Drexler, and A. F. Fercher, "Signal and resolution enhancements in dual beam optical coherence tomography of the human eye," J. Biomed. Opt. 3, 45-54 (1998).
    • (1998) J. Biomed. Opt , vol.3 , pp. 45-54
    • Baumgartner, A.1    Hitzenberger, C.K.2    Sattmann, H.3    Drexler, W.4    Fercher, A.F.5
  • 27
    • 2942703836 scopus 로고    scopus 로고
    • Real-time assessment of retinal blood flow with ultrafast acquisition by color Doppler Fourier domain, optical coherence tomography
    • R. A. Leitgeb, L. Schmetterer, W. Drexler, A. F. Fercher, R. J. Zawadzki, and T. Bajraszewski, "Real-time assessment of retinal blood flow with ultrafast acquisition by color Doppler Fourier domain, optical coherence tomography," Opt. Express 11, 3116-3121 (2003).
    • (2003) Opt. Express , vol.11 , pp. 3116-3121
    • Leitgeb, R.A.1    Schmetterer, L.2    Drexler, W.3    Fercher, A.F.4    Zawadzki, R.J.5    Bajraszewski, T.6
  • 28
  • 29
    • 10444250272 scopus 로고    scopus 로고
    • Frequency domain phaseresolved optical Doppler and Doppler variance tomography
    • L. Wang, Y. Wang, S. Guo, J. Zhang, M. Bachinan, G. P. Li, and Z. Chen, "Frequency domain phaseresolved optical Doppler and Doppler variance tomography," Opt. Commun.. 242, 345-350 (2004).
    • (2004) Opt. Commun , vol.242 , pp. 345-350
    • Wang, L.1    Wang, Y.2    Guo, S.3    Zhang, J.4    Bachinan, M.5    Li, G.P.6    Chen, Z.7
  • 30
    • 33846519303 scopus 로고    scopus 로고
    • Resonant Doppler Imaging and optical vivisection of retinal blood flow
    • A. H. Bachmann, M. Villiger, C. Blatter, T. Lasser, and R. A. Leitgeb, "Resonant Doppler Imaging and optical vivisection of retinal blood flow " Opt. Express 15, 408-422 (2007).
    • (2007) Opt. Express , vol.15 , pp. 408-422
    • Bachmann, A.H.1    Villiger, M.2    Blatter, C.3    Lasser, T.4    Leitgeb, R.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.