메뉴 건너뛰기




Volumn 17, Issue 2, 2007, Pages 705-709

Evaluation of a microwave SQUID multiplexer prototype

Author keywords

Frequency division multiplexing; Phase noise; SQUIDs; Superconducting resonators

Indexed keywords

RADIANT ENERGY; SUPERCONDUCTING RESONATORS; SYSTEM COMPLEXITY; ULTRASENSITIVE CRYOGENIC DETECTORS;

EID: 34547449769     PISSN: 10518223     EISSN: None     Source Type: Journal    
DOI: 10.1109/TASC.2007.898118     Document Type: Conference Paper
Times cited : (18)

References (16)
  • 1
    • 36448999994 scopus 로고
    • An application of electrothermal feedback for high resolution cryogenic particle detection
    • Apr
    • K. Irwin, "An application of electrothermal feedback for high resolution cryogenic particle detection," Appl. Phys. Lett., vol. 66, no. 15, pp. 1998-2000, Apr. 1995.
    • (1995) Appl. Phys. Lett , vol.66 , Issue.15 , pp. 1998-2000
    • Irwin, K.1
  • 2
    • 5444249699 scopus 로고    scopus 로고
    • Microwave SQUID multiplexer
    • Sept
    • K. D. Irwin and K. W. Lehnert, "Microwave SQUID multiplexer," Appl. Phys. Lett., vol. 85, no. 11, pp. 2107-2109, Sept. 2004.
    • (2004) Appl. Phys. Lett , vol.85 , Issue.11 , pp. 2107-2109
    • Irwin, K.D.1    Lehnert, K.W.2
  • 3
    • 0032620886 scopus 로고    scopus 로고
    • Superconducting multiplexer for arrays of transition edge sensors
    • June
    • J. Chervanek, K. Irwin, E. Grossman, J. Martinins, C. Reintsema, and M. Huber, "Superconducting multiplexer for arrays of transition edge sensors," Appl. Phys. Lett., vol. 74, no. 26, pp. 4043-4045, June 1999.
    • (1999) Appl. Phys. Lett , vol.74 , Issue.26 , pp. 4043-4045
    • Chervanek, J.1    Irwin, K.2    Grossman, E.3    Martinins, J.4    Reintsema, C.5    Huber, M.6
  • 5
    • 21944451276 scopus 로고    scopus 로고
    • Single superconducting quantum, interference device multiplexer for arrays of low-temperature sensors
    • Jan
    • J. Yoon, J. Clarke, J. Gildemeister, A. Lee, M. Myers, P. Richards, and J. Skidmore, "Single superconducting quantum, interference device multiplexer for arrays of low-temperature sensors," Appl. Phys. Lett., vol. 78, no. 3, pp. 371-373, Jan. 2001.
    • (2001) Appl. Phys. Lett , vol.78 , Issue.3 , pp. 371-373
    • Yoon, J.1    Clarke, J.2    Gildemeister, J.3    Lee, A.4    Myers, M.5    Richards, P.6    Skidmore, J.7
  • 6
    • 0012149114 scopus 로고    scopus 로고
    • SQUID-based readout schemes for microcalorimeter arrays
    • M. Kiviranta, H. Seppa, J. van der Kuur, and P. de Korte, "SQUID-based readout schemes for microcalorimeter arrays," in AIP Conf. Proc., 2002, vol. 605, pp. 295-300.
    • (2002) AIP Conf. Proc , vol.605 , pp. 295-300
    • Kiviranta, M.1    Seppa, H.2    van der Kuur, J.3    de Korte, P.4
  • 10
    • 0242300181 scopus 로고    scopus 로고
    • A broadband superconducting detector suitable for use in large arrays
    • P. Day, H. LeDuc, B. Mazin, A. Vayonakis, and J. Zmuidzinas, "A broadband superconducting detector suitable for use in large arrays," Nature, pp. 817-821, 2003.
    • (2003) Nature , pp. 817-821
    • Day, P.1    LeDuc, H.2    Mazin, B.3    Vayonakis, A.4    Zmuidzinas, J.5
  • 13
  • 15
    • 42749101743 scopus 로고    scopus 로고
    • Quantum noise in the Josephson charge qubit
    • Online, Available
    • O. Astafiev, Y. A. Pushkin, Y. Nakamura, T. Yamamoto, andJ. S. Tsai, "Quantum noise in the Josephson charge qubit," Phys. Rev. Lett. vol. 93, no. 26, p. 267007, 2004 [Online], Available: http://link.aps.org/ abstract/PRL/v93/e267007
    • (2004) Phys. Rev. Lett , vol.93 , Issue.26 , pp. 267007
    • Astafiev, O.1    Pushkin, Y.A.2    Nakamura, Y.3    Yamamoto, T.4    andJ5    Tsai, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.